Installation
ECO BETADRIVE ECO
18
81417 2.0
5.2.1
Electrical connection
CAUTION
Danger of crushing injury!
The electrical components may be connected or disconnected only when the mains power and
the battery plug (when present) are disconnected. This ensures that no uncontrolled movement
can be triggered.
If the hand switch will be used to control two drives, you must first connect both drives electrical-
ly to each other (for example, over a control unit or double drive). Then you can connect the
handset.
Routing the electrical cables
When routing the cables, be sure that:
the cables cannot get jammed,
no mechanical load (such as pulling, pushing or bending) will be put on the cables,
or
the cables cannot be damaged in any way.
Fasten all cables (especially the mains cable) to the end product using sufficient strain relief and
kink prevention methods. Be sure that the design of the end product prevents the mains cable from
coming into contact with the floor during transport.
6.2.2.
Dismantling
CAUTION
Danger of crushing injury
The electrical components may be connected or disconnected only when the mains power
and the battery plug (when present) are disconnected. This ensures that no uncontrolled
movement can be triggered.
Be sure to carry out work on the drive in a position so that no loads are bearing on it. Only in
this way can you be sure to avoid any risks of crushing or injury.
1
Move your product into a position where it is supporting no load.
2
If multiple drives are connected electrically they should be disconnected from each other.
3
Remove the srews of the adaption mechanism.
4
Remove the security clips and the mounting bolt,
or remove the srews of the mounting bracket from the end product.