background image

3

Español

Specifications  

MODEL NO.: ..................................................................................DXH35FAHC
GAS TYPE: ..................................................... FOR USE WITH PROPANE ONLY
BURN RATE (BTU/HR): .............................................35,000 BTU/hr (10.25 kW) 
ELECTRICAL INPUT ........................................................115 V, 60 HZ, 1 Ø, 3 A

•  Minimum operating voltage: 100V
•  When using an extension cord, make certain that it is a 3-wire (grounded) 

cord of proper wire size, minimum length of 6 ft (1.83m).

IGNITION .......................................................................... Manual, piezo ignition
PRIMARY FLAME CONTROL........................Thermocouple Operated Gas Valve
HIGH TEMPERATURE CONTROL ...............................................240 °F (116 °C)

Minimum ambient temperature rating: 0 °F (-17.8°C)

Operating Precautions

This is a propane, direct-fired, forced air heater. It’s intended use is primarily 
temporary heating of buildings under construction, alteration or repair.
Propane is heavier than air. If propane leaks from a connection or fitting, it sinks to the 
floor, collecting there with the surrounding air, forming a potentially explosive mixture. 
Obviously, propane leaks should be avoided, so set up the propane supply with 
utmost care. Leak check new connections or reconnections with a soap and water 
solution applied to connection: look for bubbles, listen for hiss of escaping gas, feel 
for extreme cold, smell for rotten egg odor. Do not use if leaking! Follow all connection 
instructions herein. Also, ask your propane dealer for advice on the propane 
application and supply installation and ask him to check it if there are any questions.
This heater was designed and certified for use as a construction heater in accordance 
with ANSI Standard Z83.7 

•  

CGA 2.14. Check with your local fire safety authority if 

you have any questions about your applications. Other standards govern the use of 
fuel gases and heat producing products in specific applications. Your local authority 
can advise you about these.
Direct-Fired means that all of the combustion products enter the heated space. Even 
though this heater operates very close to 100 percent combustion efficiency, it still 
produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic. 
We can tolerate small amounts but not a lot. CO can build up in a heated space 
and failure to provide adequate ventilation could result in death. The symptoms of 
inadequate ventilation are:

•  headache 
•  dizziness
•  burning eyes and nose 
•  nausea
•  dry mouth or sore throat

So, be sure to follow advice about ventilation in these operating instructions.
Forced Air means that a blower or fan pushes the air through the heater. Proper 
combustion depends upon this air flow; therefore, the heater must not be revised, 
modified or operated with parts removed or missing. Likewise, safety systems must 
not be circumvented or modified in order to operate the heater.
When the heater is to be operated in the presence of other people the user is 
responsible for properly acquainting those present with the safety precautions and 
instructions, and of the hazards involved.

Maximum Pressure to Regulator ................................................. Bottle Pressure
Minimum Pressure to Regulator .................................................20 psi (138 kPa)
Pressure From Regulator [Manifold Pressure] ...........................10 psi (68.9 kPa)
Fuel Consumption:  .......................................................... 1.6 lbs/hr (0.72 kg/hr)

Gas Supply

WARNING: If the information in this manual is not followed exactly, 
a fire or explosion may result causing injury or loss of life.

- Do not store or use gasoline or other flammable vapors and liquids in the 

vicinity of this or any other appliance.

- An LP cylinder not connected for use shall not be stored in the vicinity of this 

or any other appliance.

- WHAT TO DO IF YOU SMELL GAS

 

Ǟ

Do not try to light appliance.

 

Ǟ

Extinguish any open flame.

 

Ǟ

Shut off gas to appliance.

- Service must be performed by a qualified service agency.

Summary of Contents for DXH35FAHC

Page 1: ...S CAREFULLY Read and follow all instructions Place instructions in a safe place for future reference Do not allow anyone who has not read these instructions to assemble adjust or operate the heater VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS Lisez et observez toutes les instructions Conservez ces instructions dans un endroit sécuritaire pour vous y référer ultérieurement Interdisez à quiconque n ...

Page 2: ...ON AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PARTICLES OR UNKNOWN CHEMICALS The heater is designed and approved for use as a construc...

Page 3: ...uthority can advise you about these Direct Fired means that all of the combustion products enter the heated space Even though this heater operates very close to 100 percent combustion efficiency it still produces small amounts of carbon monoxide Carbon monoxide called CO is toxic We can tolerate small amounts but not a lot CO can build up in a heated space and failure to provide adequate ventilati...

Page 4: ...e building and area before you return Properly trained service people must repair any leaks check for further leakages and then relight the appliance for you Odor Fading No Odor Detected Some people cannot smell well Some people cannot smell the odor of the man made chemical added to propane LP or natural gas You must determine if you can smell the odorant in these fuel gases Learn to recognize th...

Page 5: ...electrical connection and grounding must comply with National Electrical Code ANSI NFPA 70 USA and CSA C22 1 Canadian Electrical Code Part 1 Canada 15 Use only a properly grounded 3 prong receptacle or extension cord 6 ft 1 83m in length minimum Safety Precautions 16 Do not move handle or service while hot or burning 17 Use only in accordance with local codes or in the absence of local codes with ...

Page 6: ...ter There are no unplanned or unexplained shut downs of the heater The parts lists and exploded view show the heater as it was constructed Do not use a heater which is different from that shown In this regard use only the hose regulator and cylinder connection fitting called a POL fitting supplied with the heater IMPORTANT Match the color stripe on the hang tag attached to the hose assembly with t...

Page 7: ...Assembly 1 22130 Wire Assembly 1 8 28091 Nut Hex M8 x 1 Fine Thd Thermocouple 2 9 28077 Fan Blade 6 75 x 75 Pitch 1 10 28076 Motor 0 74 A 1 11 22101 Grille Assembly 1 Part Description Qty 12 40801 Handle 1 13 82136 Bushing Strain Relief 1 14 22113 Power Cord Assembly 1 15 26168 High Limit Switch 240 F 116 C 1 16 28082 Thermocouple 1 17 28080 Electrode 1 DXH35FAHC REPLACEMENT PARTS LIST 3 2 8 9 11 ...

Page 8: ...ON PURCHASING Accessories may be purchased at any Dewalt local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll Free 855 805 5745 www dewalt com Our office hours are 8 00 AM 5 00 PM EST Monday through Friday Please include the model number date of purchase and description of problem in all communication LIMITED WARRANTY DeWalt warrants its heaters and accessorie...

Page 9: ...S CAREFULLY Read and follow all instructions Place instructions in a safe place for future reference Do not allow anyone who has not read these instructions to assemble adjust or operate the heater VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS Lisez et observez toutes les instructions Conservez ces instructions dans un endroit sécuritaire pour vous y référer ultérieurement Interdisez à quiconque n ...

Page 10: ...CHIMIQUES INCONNUS L appareil de chauffage est conçu et approuvé pour être utilisé comme appareil de chauffage standard selon la norme ANSI Z83 7 CSA 2 14 VÉRIFIEZ AVEC VOTRE AUTORITÉ LOCALE DE SÉCURITÉ INCENDIE SI VOUS AVEZ DES QUESTIONS SUR LES APPLICATIONS Cet appareil de chauffage portatif n est pas ventilé Il utilise l oxygène de l air ambiant Une circulation d air adéquate doit être assurée ...

Page 11: ...Le fonctionnement à feu direct de cet appareil signifie que tous les produits de combustion se retrouvent dans l air ambiant Même si l efficacité de combustion de l appareil de chauffage est presque complète il produit quand même de petites quantités de monoxyde de carbone Le monoxyde de carbone appelé CO est toxique Notre organisme ne peut en supporter que de faibles quantités Il est possible que...

Page 12: ...chappé Demandez leur d aérer la zone du bâtiment avant votre retour Les gens de service dûment formés doivent réparer les fuites éventuelles vérifier plus de fuites puis vous rallumer l appareil Declin d odeur pas d odeur detectee Certaines personnes ne peuvent pas bien sentir Certaines personnes ne peuvent pas sentir l odeur du produit chimique artificiel ajouté au propane et le gaz naturel Vous ...

Page 13: ...ée et la sortie d air 14 N utilisez qu avec l alimentation électrique spécifiée Le raccordement électrique et la mise à la terre doivent être conformes au Code national de l électricité ANSI NFPA 70 aux États Unis et à la norme CSA C22 1 partie 1 du Code canadien de Précautions Liées à la Sécurité l électricité au Canada 15 N utilisez qu avec une fiche à trois broches mise à la terre correctement ...

Page 14: ...Il n y a pas de forte odeur désagréable pas de sensation de brûlure aux yeux ni de malaise physique général Il n y a pas présence de fumée ni de suie à l intérieur ou à l extérieur de l appareil de chauffage Il ne se produit pas d arrêts imprévus ou inexpliqués de l appareil La liste des pièces et le schéma du câblage illustrent la construction détaillée de l appareil de chauffage N utilisez pas u...

Page 15: ...teur 1 22130 Câblage 1 8 28091 Écrou hex M8 x 1 filet fin pour thermocouple 2 9 28077 Ailette de ventilateur inclin 6 75 x 0 75 1 10 28076 Moteur 0 74 A 1 11 22101 Grille 1 12 40801 Poignée 1 13 82136 Réducteur de tension de la bague 1 14 22113 Cordon 1 15 26168 Contacteur de commande max 116 C 240 F 1 16 28082 Thermocouple 1 17 28080 Électrode 1 DXH35FAHC LISTE DES PIÈCES 3 2 8 9 11 10 14 13 15 1...

Page 16: ...ORMATION CONCERNANT LE SERVICE Appeler sans frais au 855 805 5745 www dewalt com Nos heures d ouverture sont de 8h00 à 17h00 H N E du lundi au vendredi Veuillez inclure votre numéro de modèle la date d achat et une description du problème dans toutes vos communications GARANTIE LIMITÉE DeWalt garantit que ses radiateurs et ses accessoires sont exempts de tout défauts de matériaux et de fabrication...

Page 17: ...S CAREFULLY Read and follow all instructions Place instructions in a safe place for future reference Do not allow anyone who has not read these instructions to assemble adjust or operate the heater VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS Lisez et observez toutes les instructions Conservez ces instructions dans un endroit sécuritaire pour vous y référer ultérieurement Interdisez à quiconque n ...

Page 18: ...ón de acuerdo con la norma ANSI Z83 7 CSA 2 14 COMPRUEBE CON SU AUTORIDAD LOCAL DE SEGURIDAD CONTRA INCENDIOS SI TIENE PREGUNTAS ACERCA DE LAS SOLICITUDES ADVERTENCIA Una de las sustancias que se desprende en la com bustión al usar este equipo es el monóxido de carbono un producto quími co que de acuerdo con el estado de california produce cáncer y defectos de nacimiento u otros daños reproductivo...

Page 19: ...uthority can advise you about these Direct Fired means that all of the combustion products enter the heated space Even though this heater operates very close to 100 percent combustion efficiency it still produces small amounts of carbon monoxide Carbon monoxide called CO is toxic We can tolerate small amounts but not a lot CO can build up in a heated space and failure to provide adequate ventilati...

Page 20: ...chappé Demandez leur d aérer la zone du bâtiment avant votre retour Les gens de service dûment formés doivent réparer les fuites éventuelles vérifier plus de fuites puis vous rallumer l appareil Declin d odeur pas d odeur detectee Certaines personnes ne peuvent pas bien sentir Certaines personnes ne peuvent pas sentir l odeur du produit chimique artificiel ajouté au propane et le gaz naturel Vous ...

Page 21: ...orriente especificada La conexión eléctrica y a tierra debe cumplir con los requisitos del Código Eléctrico Nacional ANSI NFPA 70 EE UU y del Código Eléctrico Canadiense CSA C22 1 Primera parte Canadá 15 Utilice únicamente un cable de extensión mínimo 1 83 m 6 pies de longitud o un PRECAUCIONES DE SEGURIDAD receptáculo de tres patas correctamente conectado a tierra 16 No lo mueva manipule ni ajust...

Page 22: ...hollín dentro ni fuera del calentador El calentador no se apaga inesperadamente o inexplicablemente Las listas de piezas y el diagrama extendido muestran la configuración original del calentador No utilice un calentador que sea diferente del que se muestra En este sentido utilice únicamente la manguera el regulador y el acople de conexión denominado acople POL suministrados con el calentador IMPOR...

Page 23: ...to de manguera y regulador 1 22130 Conjunto de cables 1 8 28091 Tuerca hexagonal M8 x 1 Termocupla rosca fina 2 Part Description Qty 9 28077 Aspas del ventila dor 6 75 x 0 75 de inclinación 1 10 28076 Motor 0 74 A 1 11 22101 Conjunto de la rejilla 1 12 40801 Manipular 1 13 82136 Cojinete de liberación de tensión 1 14 22113 Conjunto de cable de alimentación 1 15 26168 Interruptor limitador máximo 2...

Page 24: ... COMPRAS Puede comprar accesorios en cualquier distribuidor local de Dewalt o directamente de la fábrica POR INFORMACIÓN ACERCA DE REPARACIONES Llame sin cargo al 855 805 5745 www dewalt com Nuestro horario de trabajo es de 08 00 a m AM a 5 00 PM de lunes a viernes hora del este Por favor incluya el número de modelo la fecha de compra y la descrip ción del problema en todas sus comunicaciones GARA...