Maintenance chart
ACTION
WHY
HOW
Clean magazine and feeder
mechanism.
Prevent a jam.
Blow clean daily.
Keep contact arm working
properly.
Promote operator safety and
efficient Nailer operation.
Blow clean daily.
Internal cleaning
Keep tool efficiency
Follow mentioned procedure every 20.000 shots
(less in dirty environment)
Operator troubleshooting
PROBLEM
CHECK METHOD
CORRECTION
Nailer operates, but no nail
is driven.
Check for a jam.
Clear the jam.
Check function of the nail feeder.
Clean and lubricate if required.
Ribbon spring weakened or damaged?
Replace ribbon spring.
Check the correct nails are being used.
Use only recommended nails.
Check if the driver blade piston is not returned
to the top position
Remove the battery, fuel cell & nails from the tool and, using a
thin piece of metal of screwdriver 100mm long (not included),
insert into the contact arm and push the bar to the top position.
Skipping nails.
Intermittent feed.
Check for proper nails.
Use only recommended nails.
Check function of nail feeder.
Clean and lubricate.
Ribbon spring weakened or damaged?
Replace ribbon spring.
Nail feeder worn or damaged?
Replace nail feeder.
Check for returning of piston.
Pull the trigger firmly and for about 0.5 sec after combustion.
Too low temperature, warm up fuel cell under 50°C (120°F).
Nails jam.
Driven nail is bent.
Check for proper nails.
Use only recommended nails.
Driver blade worn?
Contact
D
e
WALT
for replacement.
Nail feeder worn or damaged?
Replace nail feeder.
The operation of the contact arm
not smooth.
Contact arm bent?
Contact
D
e
WALT
for replacement.
Check contact arm’s moving track for debris.
Contact
D
e
WALT
for replacement.
Fan is working, light indicator
shows GREEN yet it doesn’t
drive a nail or operation
unstable.
Check for returning of piston.
Push the contact arm all the way.
Too low temperature, warm up fuel cell under 50°C (120°F).
Check fuel cell, insufficient?
Exchange it with a new fuel cell.
Check spark plug wire, worn out?
Contact
D
e
WALT
for replacement.
Check spark plug, grease or debris?
Contact
D
e
WALT
for replacement.
Check filter, clogged?
Clean in accordance with the maintenance chart.
Fan does not operate when push
lever is pressed.
Magazine empty.
Load more nails in the magazine.
Note the color of the light indicator.
If red: charge the battery.
If green: Contact
D
e
WALT
for replacement.
Unable to charge battery.
Check the electrical cord.
18