background image

PAGE  2        Sb-21-092-b

Condition  

CAuSe  

 CorreCtion 

trouBleSHooting

either flat blade terminal. the 

wire with insulation, having 

an outer surface that is green 

with or without yellow stripes, 

is the grounding wire. if the 

grounding instructions are not 

completely understood, or if in 

doubt as to whether the product 

is properly connected, check 

with a qualified electrician or 

serviceman. if the plug will not 

fit the outlet, do not modify it. 

Have the proper outlet installed 

by a qualified electrician. do not 

use temporary adapter plugs 

with this compressor.

eXtenSion CordS

If it is necessary to use an extension cord, 

use a 3-wire extension cord that has a 

3-blade grounding plug and a 3-slot re-

ceptacle that will accept the plug on the 

product.  Your extension must be in good 

condition and not less than 16 gauge for 

25 feet, 14 gauge for 50 feet and 12 gauge 

for 100 feet.  Undersized cords will cause 

a drop in line voltage resulting in loss of 

power and overheating. The smaller the 

gauge number, the heavier the cord.

Compressor starts and stops during 

continuous spray use.

Stopping and starting of the compressor 

when the airbrush is not in use.

Your airbrush is not using enough air to 

prevent the back pressure buildup.

An air leak in the hose-regulator  

connections.

For single piston Airblade

TM

, increase 

air pressure to airbrush.

See "SEALING OF AIR HOSE" instruc-

tions. A short running of the compres-

sor for one or two seconds every five 

minutes is normal.

this unit does not require any 

lubricants or oil. Applying oil to 

any part could result in damage 

to the compressor.  All bearings, 

including those in the motor, are 

grease packed.  

 

grounding inStruCtionS

This product must be grounded. This 

product is equipped with a cord having 

a grounding wire with a grounding plug. 

The plug must be plugged into an outlet 

that is properly installed and grounded 

in accordance with all local codes and 

ordinances.

improper installation of the 

grounding plug can result in the 

risk of electrical shock.

if it is necessary to repair or 

replace the cord or plug, do not 

connect the grounding wire to 

Compressed air can propel dust, 

dirt or loose particles it comes 

in contact with. to prevent pos-

sible injury always wear safety 

goggles or glasses when using 

the air compressor. never point 

any nozzle or sprayer toward a 

person or any part of the body.  

Always turn the air compressor 

off before attaching or remov-

ing accessories.

Your air compressor is powered 

by electricity. like any other 

electrically powered devises, 

if it is not used properly it can 

cause electrical shock.  Always 

unplug the air compressor prior 

to maintenance or repair. make 

sure to plug the cord into an 

electrical outlet with the speci-

fied voltage and adequate fuse 

protection.

Summary of Contents for AIRBLADE DGR-518-1

Page 1: ...THERMAL PROTECTOR The motor of this compressor is equipped with a thermal overload protector If the motor should overheat the overload pro tector will shut off the motor If this should occur unplug t...

Page 2: ...nections For single piston AirbladeTM increase air pressure to airbrush See SEALING OF AIR HOSE instruc tions A short running of the compres sor for one or two seconds every five minutes is normal Thi...

Page 3: ...PROTECTOR T RMICO Elmotordeestecompresorest equipado con un protector t rmico de sobrecarga Si el motor se recalentara el protector de sobrecarga har detener el motor Si esto ocurre desenchufe el com...

Page 4: ...tmos f rica al aer grafo Consulte las instrucciones bajo SELLADO DE LA MANGUERA NEUM TICA Un funcionamiento breve del compresor por 1 o 2 segun dos cada 5 minutos es normal Nosenecesitalubricantesniac...

Page 5: ...n Poids d exp dition 4 3 kg 9 4 lbs PROTECTEUR THERMIQUE Le moteur de ce compresseur est muni d un protecteur thermique contre les surcharges En cas de surchauffe du moteur le protecteur thermique l t...

Page 6: ...ion TANCH IT DU TUYAU D ARRIV E D AIR Un cycle court de fonction nement du compresseur pendant une ou deux secondes aux cinq minutes est normal Cet appareil ne requiert pas l utilisation de lubrifiant...

Page 7: ...SB 21 092 B PAGE 7...

Page 8: ...autorizados en todo el mundo Para equipos repuestos y servicio de mantenimiento consulte las P ginas Amarillas bajo Equipos y suministros para talleres de repintado automotriz Para asistencia t cnica...