14
© 2012 Finishing Brands UK Ltd.
Parts Replacement/Maintenance
Chart 1
– Air Caps
NOTE: When removing air cap from
retaining ring, don’t remove the Slip Ring (2) or Retaining Ring Seal (5) from
the Retaining Ring. Damage to the parts may occur. Slip ring and Retaining Ring seal are not available as
replacements. Simply wipe parts clean and reassemble with new or clean air cap.
Chart 2
– Fluid Nozzle Range & Fluid Needle
PART No. ON FLUID NOZZLE
PART No. NEEDLE
FOR AIRCAPS
SP-200S-085-K
ADV-310-085-K
430
443
497
SP-200S-10-K
ADV-310-10-K
SP-200S-12-K
ADV-310-12-K
SP-200S-13-K
ADV-310-13-K
SP-200S-14-K
ADV-310-14-K
SP-200S-16-K
ADV-310-16-K
SP-200S-18-K
ADV-310-18-K
SP-200S-20-K
ADV-310-20-K
SP-200S-22-K
ADV-310-22-K
SP-247S-22-K
ADV-310-22-K
470
SP-247S-28-K
ADV-310-28-K
Chart 3
– Optional Fluid Nozzles & Fluid Needles
PART No. ON FLUID NOZZLE
PART No. NEEDLE
MATERIAL
FOR AIRCAPS
SP-200N-14-K
ADV-310N-14-K
HARDENED
430
443
497
SP-200N-18-K
ADV-310N-18-K
HARDENED
SP-200N-22-K
ADV-310N-22-K
HARDENED
SP-200S-10-K
ADV-310P-10-K
PLASTIC TIPPED
SP-200S-12-K
ADV-310P-12-K
PLASTIC TIPPED
SP-200S-14-K
ADV-310P-14-K
PLASTIC TIPPED
SP-247N-22-K
ADV-310N-22-K
HARDENED
470
SP-247N-28-K
ADV-310N-28-K
HARDENED
SP-247C-22-K
ADV-310C-22-K
CARBIDE
SP-247C-28-K
ADV-310C-28-K
CARBIDE
NOTE: When replacing the fluid nozzle or fluid needle, replace both at the same time. Torque to 9
–11 Nm (80–100
ft-ins
). Don’t over tighten the fluid nozzle. Use SN-28 10mm Spanner supplied with the gun and check with a torque
wrench.
PART No. FOR
AIR CAP
SUCTION OR
PRESSURE
TECHNLOGY
MARKING ON
AIR CAP
RECOMMENDED INLET
PRESSURE
(bar)
AIR FLOW
(L/min) @ 3
bar
SP-100-430-K
SUC & PRESS
CONVENTIONAL
430
3.0
290
SP-100-443-K
SUC & PRESS
CONVENTIONAL
443
3.0
325
SP-100-497-K
PRESSURE
CONVENTIONAL
497
3.0
500
SP-100-470-K
PRESSURE
CONVENTIONAL
470
3.0
460