Error messages
Deutschmann Automation GmbH & Co. KG
44
Instruction manual LOCON 7, LOCON 9 V. 10.4
24.5.04
All outputs are switched briefly to 0 V when error 31 is acknowledged.
32
EEPROM full
All data records in the EEPROM are used. Either
you must remove cams no longer required or the
unit must be equipped with a higher-capacity mem-
ory card (LOCON 32 only).
33
Duplicate switch-on point
An attempt has been made to program two cams
with the same switch-on point at an output (cam
track).
34
Error programming a partial idle time com-
pensation
Unit does not feature the ‘Y’ partial idle time com-
pensation option
35
Illegal encoder resolution, no power of 2
Program a valid value
36
An attempt has been made to activate the
protocol function but no 16k memory card
is fitted (LOCON 32 only)
Insert 16k memory card
37
Reserved
38
Error programming an idle time
On LOCON 17 only - idle times are permitted only
for outputs 1 to 8
39
ERROR No ITC No ITC possible
e.g. LOCON 7
40
DICNET® - transmit error
Duplicate error on transmit
Duplicate error on transmit
41
DICNET® - receive error
Duplicate error on receive
42
DICNET® - ID error
There is already a user with the same device num-
ber (GNR) in the network or the network line is
faulty (missing bus termination, line discontinuity or
non-twisted lines).
43
DICNET® bus error
44
Overflow of the serial receive buffer
45
External fault signal (X26 only)
46
Save blank cam
Data record incomplete
47
Direction-dependent output update illegal
50
Outputs deactivated (brake cam option only)