24.5.04
Instruction manual LOCON 7, LOCON 9 V. 10.4
37
Deutschmann Automation GmbH & Co. KG
Initialization of encoder resolution, counting area, DICNET-ID
8
Initialization of encoder resolution, counting area, DICNET-ID
(LOCON 9 only)
For LOCON 9 it is possible to parameterize the device number in the net (DICNET-ID), the
encoder resolution and in to connection with incremental encoders the counting area. An initial-
ization can be made via TERM 24, TERM 32 or with WINLOC only.
8.1
Parameter’s set in factory
Default
Value range
Device number (DICNET-ID)
:
0
0..15
Encoder resolution (SSI)
:
360
360, 1000, 2n n=0..15
Encoder resolution (incremental)
:
500
1..65535
Counting area (only for inc. version)
:
65536
1..32767 and 65536
8.2
Initialization via TERM 24
In the terminal’s configuration menu the corresponding parameters are adjusted to the desired
value and confirmed.
Thereupon LOCON 9 carries out a warm start and is operational with the new parameters.
8.3
Initialization via TERM 32
In the terminal’s configuration menu the corresponding parameters are adjusted to the desired
value and confirmed.
Thereupon LOCON 9 carries out a warm start and is operational with the new parameters.
8.4
Initialization via PC
A connection to LOCON 9 is established with the help of the program WINLOC. Please note that
every LOCON 9 is configured to the device number (DICNET-ID) 0 in the state of delivery.
By entering Control-N (simultaneously pressing the keys “Strg“ and “N“ on the PC) it can be
branched to the initialization menu of LOCON 9.
There all parameters are queried interactively. After a change was made LOCON 9 carries out a
warm start and reports the new parameters.