24.5.04
Instruction manual LOCON 7, LOCON 9 V. 10.4
43
Deutschmann Automation GmbH & Co. KG
Error messages
11 Error messages
A LOCON error message can be seen from the fact that an error code is shown on the display.
In addition, the optional Run-Control relay drops out if a serious error (1..19, 31, 100..255) has
occurred.
All errors must be acknowledged with
.
A distinction can be made between the following error types:
11.1 Error number 1..19 (irrecoverable error)
These errors are errors occurring during the self-test routine. If one of the errors 1 to 19 occurs,
the unit must be returned to the manufacturer. When returning the unit, please provide the infor-
mation specified in chapter "Returning a unit".
11.2 Error number 20..99 (warning)
The cam control continues running in the background in the case of all errors of this chapter, i.e.
the outputs are still updated as a function of the encoder value in the specified cycle time.
Error No.
Significance
Remarks
20
Error writing to EEPROM
21
Error saving zero-point offset
22
Error saving a cam value
23
Error deleting a data record
24
Error deleting a program parameter
Parameters can be deleted only in program 0
25
Error copying a program
Error shifting a cam track
26
Time-out accessing LCD
Acknowledge error. If the error occurs again, the
unit must be returned specifying the information
described in chapter ‘Returning a unit’.
27
Error saving a pattern value
28
Error programming an idle time
Only in the case of pattern units
29
Error in function CLEAR_CAM
X97 only
30
No programming enable
The program can be modified only if signal ”Prog
Enable) is at 24 V on the connector or if parameter
”Lockable outputs” is set appropriately
31
Overload switch-off of the output driver
The output drivers are short-circuit-proof. If
LOCON or ROTARNOCK senses an overcurrent
for a long period (under certain circumstances,
also in the case of incandescent lamps with high
power rating), this error message is issued.
The corresponding output load must then be
reduced and after that the error then be acknowl-
edged.
Only the overloaded output is switched off. The
other outputs continue to operate.