Cam control LOCON 7 and LOCON 9
Deutschmann Automation GmbH & Co. KG
12
Instruction manual LOCON 7, LOCON 9 V. 10.4
24.5.04
3
Cam control LOCON 7 and LOCON 9
3.1
Structure of the unit
According to the picture below, the complete device is stored in a plastic housing for DIN-rail
mounting (79x96x25 WxHxD):
3.2
Pin assignment LOCON 7 and LOCON 9
18 pol. screw-plug connector with the following assignment:
The power consumption at +24V is max. 100mA without load. The power that is required as load
on the output 1 to output 8 (max. 1A), must additionally be available over +24V.
Pin-No.
Connection SSI-encoder
Connection incremental encoder
Count-/direction signals
1
SelectNumber
SelectCount
2
SSIDAT-
Clear+
Clear+
3
SSICLK-
Inc-track B
Down
4
Inc-track A
Count
5
Prog-No. 1
6
Prog-No. 2
Clear (X42 only)
7
Output 1
8
Output 2
9
Output 3
10
Output 4
11
Output 5
12
Output 6
13
Output 7
14
Output 8
15
Tx-LOCON /
16
Rx-LOCON / DICNET-
17
GND
18
+24V