DDEC VI SERIES 60 TROUBLESHOOTING GUIDE
2.4.5.4
Shrink Wrap
Shrink wrap is required when splicing non insulated connections. Raychem HTAT or any
equivalent heat shrink dual wall epoxy encapsulating adhesive polyole
fi
n is required. Shrink wrap
must extend at least .25 in. (6 mm) over wire insulation past splice in both directions.
To heat shrink wrap a splice:
NOTICE:
The heat shrink wrap must overlap the wire insulation about
.25 in. (6 mm) on both sides of the splice.
1. Select the correct diameter to allow a tight wrap when heated.
2. Heat the shrink wrap with a heat gun; do not concentrate the heat in one location, but
apply the heat over the entire length of shrink wrap until the joint is complete.
3. Repeat step 2 to apply a second layer of protection (if required by splicing guidelines).
All information subject to change without notice.
PRELIMINARY 6SE567 0512
Copyright © 2005 DETROIT DIESEL CORPORATION
2-37