LUBRICATION AND PREVENTIVE MAINTENANCE INTERVALS
Fuel Pro® 382 Filters
Install new Fuel Pro® 382 primary
fuel
fi
lter elements when the fuel
level in the see-thru cover reaches the
top of the element or after one year
of service, whichever comes
fi
rst.
Refer to section Replace “Fuel Pro®
382/382E” Fuel Filter Element.
Item 12 – Water Pump and
Coolant Inhibitor Element
Water Pump
Water Pump Drain Hole –
The water
pump drain hole should be inspected
every 6 months to make sure it is
open. A small chemical build-up
or streaking at the drain hole may
occur.
This is not an indication of
a defective water pump or seal.
Remove the build-up with a mild
detergent cleaner and a brush. If
coolant does not leak from the drain
hole under normal conditions, do not
replace the water pump.
Coolant Inhibitor Element
The coolant must be tested at required
intervals and the coolant inhibitor
element replaced, if required.
1. Spin-on
Inhibitor
Element
2.
Filter
Adaptor
Figure 18 Installing Coolant
Inhibitor Element
Required test intervals are
listed in Table 28 . For SCA
test procedures refer to section G.
How to Select Coolant and then
refer to section SCA Test Procedures
in this guide. Use the coolant
fi
lter
element required. Refer to section
Power Cool
Engine Products for
element part number listing. The
valves mounted on the
fi
lter adaptor
head
must
be opened after the element
is replaced.
Item 13 – Cranking Motor
For cranking motor (starter) assembly
information, contact an authorized
Delco Remy® distributor.
66
All information subject to change without notice.
(Rev. May 2004)
DDC-SVC-MAN-0057 0305