HOW-TO SECTION
Power Cool
3000 Coolant Concentration Limits
Boron
125 – 500 PPM
Nitrite
900 – 3200 PPM
Nitrate
0 – 1000 PPM
Silicon
50 – 250 PPM
Phosphorous
0 PPM
pH
8.0 – 11.0
Table 26
Power Cool
3000 Concentration Limits (5%
Power Cool
3000/ 95% Water)
Power Cool
3000 SCA inhibitors
should be mixed at 5% by volume
with water. This is 1 quart per 5
gallons of water. These additions
can be made by adding liquid SCAs
available in a variety of sizes. Coolant
fi
lters are also available for different
cooling system capacities. These
fi
lters release the proper amount of
SCA at initial
fi
ll.
Water Requirements —
Distilled, reverse osmosis-puri
fi
ed,
or de-ionized water which eliminates
the adverse effects of minerals in
tap water is preferred. High levels
of dissolved chlorides, sulfates,
magnesium, and calcium in some tap
water causes scale deposits and/or
corrosion. These deposits have been
shown to result in water pump failures
and poor heat transfer, resulting in
overheating. If tap water is used, the
mineral content in the water must be
below the maximum allowable limits
listed in Table 27.
Maximum Allowable
Parts per Million
Grains per Gallon
Chlorides
40
2.5
Sulfates
100
5.8
Total Dissolved Solids
340
20
Total Hardness –
Magnesium and Calcium
170
10
Table 27 Satisfactory Water Limits – Make-Up Water Only
94
All information subject to change without notice.
(Rev. May 2004)
DDC-SVC-MAN-0057 0305