16-1/2"
Door Foot Installation
(Right Hand Push shown Left Hand Push opposite)
Door Foot
104852 Page 9
Turn the 3-way toggle switch to the OFF position and close the door.
The center of the door foot should be located 16-1/2" from the hinge side of the
door frame stop and should be level when the rod is inserted in the sleeve attached
to the arm.
Mark the door for the door foot holes and secure the foot to the door with the
supplied screws (sexnut use is optional).
1/4-20 Sexnut
P/N: 101616-9 (630 finish) or
101616-25 (613 finish)
1/4-20 x 1" PFH Machine Screw
P/N: 102271-116 (stainless) or
102271-316 (black)
#14 x 1 PFH Self-drilling screw
P/N: 103277-316
3/8-24 x 1-3/4" Hex Cap Screw
P/N: 12739-1 (Al)
12739-2 (Blk)
3/8-24 x 1-1/4" Hex Cap Screw
P/N: 12743-1 (Al)
12743-2 (Blk)
1/4-20 x 1" Sockethead Cap Screw
P/N: 12742-1 (Al)
12742-2 (Blk)
3/8-24 Acorn Nut
P/N: 12741-1 (Al)
12741-2 (Blk)
Push Arm hardware:
or
(some of the hardware is shipped pre-assembled)
(Right Hand Push shown Left Hand Push opposite)
Apply
blue thread locker
to set screws and tighten
to secure the rod.
Rod Adjustment
The arm will rotate to the full open position.
hold the steel rod next to the rod connector
at the end of the arm.
Mark and cut the rod so it will fit into the rod connector.
The rod length should allow the rod to be secured with
both set screws and allow for adjustment of the door opening.
NOTE:
ROTATE CONNECTOR SO THAT SETSCREWS ARE NOT
FACING TOWARDS THE FLOOR.
Insert the rod into the connector with the door in full open
position and adjust until the desired opening is achieved.
Apply
blue thread locker
to set screws and tighten to secure the rod.