ARM
Tighten arm
screw
Install screw
and
safety washer
from
hardware kit
104852 Page 8
120 VAC Connections
Have a licensed electrician bring 120 VAC to the Detex Low Energy Automatic Door Operator in accordance with all local and state
electrical codes.
Be sure the 120 VAC power source is turned off before proceeding.
The 120 VAC power line can be run thru the knockout hole at the end of the operator case and into the outlet box provided.
DO NOT
route
ANY WIRES
thru enclosure top hole.
You should inspect all wiring at this time before turning on power and connecting electrical cord to outlet connector
.
Connection from 120 VAC source
performed by licensed electrician.
route thru
j-box hole
10-32 x 1/2" PPH
1-1/4" dia.
.203 dia center hole
Motor output shaft in
full open position
Push Arm Installation
The UDC 1000 controller must be plugged in and powered up. The controls are preset to approximate
settings. Refer to instruction 104827.
Set the toggle switch located at the end of the enclosure to the HOLD position.
Tighten the screw on the arm to secure it to the shaft.
Realign arm in proper position.
Tighten the arm screw on the arm to secure it to the shaft and install the 10-32 x 1/2" screw with
blue thread locker
and the safety washer to
the bottom of shaft.
(Right Hand Push shown Left Hand Push opposite)
Hot (black) to brass screws
Neutral (white) to silver screws
Ground (green) to ground
Apply
blue thread locker
and install screw and
safety washer from
hardware kit