With ASSEMBLY perpendicular to enclosure,
insert splined shaft into shaft hole
Rotate ASSEMBLY to an almost horizontal
position being careful not to let switch
assembly hit enclosure
Switch assembly
Rotate ASSEMBLY into enclosure,
letting shoulder of gearbox drop down
into shaft hole. Align screw holes at
bottom and apply
blue thread locker
to all 4 screws before tightening
(note: for clarity, switch wires not shown in views)
104852 Page 7
Motor-Gearbox Assembly Installation
Remove MOTOR-GEARBOX ASSEMBLIES from their cartons and match them to the proper ends of the case: see
Receiving Inspection
view on page 5. Motors will be marked with a label as either LH PUSH or RH PUSH.
With the motor end away and slightly below the open edge of the case, insert the ASSEMBLY shaft
through the hole in the bottom of the case (see below).
Carefully lift and turn the ASSEMBLY into the case, being careful not to damage the switch assembly on the top (see below).
Secure the ASSEMBLY to the bottom of the case with the 1/4-20 x 1 3/4" Phillips flathead screws provided.
Attach the motor ground wire (green) to the back of the case where labeled with the 10-24 x 1/4" Phillips button head screw provided.
Connect the white plug of the ASSEMBLY harness into the UDC 1000 Controller.
Repeat process for opposite side.
DO NOT
route
ANY
WIRES
thru enclosure top
holes
1/4-20 x 3/4" PFH
Apply
blue thread locker