Hanger Plate Installation
The edge of the hanger plate should be located 1-1/8" past the inside edge of the frame face on the hinged side of the frame, level and flush
with the bottom of the header of the door frame. Bar clamp the hanger plate. Using hanger plate, mark and drill holes into header frame, solid
wall or wall stud.
Fasten using appropriate type and size screws (Detex recommends using flat head type).
Note: Drilling debris accumulated in hanger groove tracks can prevent the operator from seating uniformly when mounting.
Remove debris with thin brush. Masking tape can also be used to prevent debris from collecting in groove.
Lift the operator and lower onto the webs of the hanger plate bracket.
Be sure both top and bottom are engaged.
Once they are seated, pull down until unit is completely flush and screws can be replaced in top corners.
104852 Page 6
#14 x 1-1/2" PFH
SECURE HANGER WITH SCREWS
HANGER PLATE
REPLACE
SCREW
HERE
REPLACE
SCREW
HERE
Note: If installing onto masonry type wall,
use Tapcon screws where needed.
HINGED SIDE
1-1/8" from INSIDE
edge of frame face
to END of Hanger plate