THE DETEX LOW ENERGY AUTOMATIC DOOR OPERATOR IS TO BE USED WITH APPROVED SWITCHES.
Typically you will use a wall mounted, hard wired push button for activation. You must provide wire from the push button switch to the Control
Module inputs. Knockouts are available on the enclosure for wire runs. The connections are terminated on
terminals #1 and #2 of the Control
Module
. Refer to the diagram included with the Control Module.
ALL WIRING MUST MEET ALL STATE AND LOCAL CODES.
You must disconnect all voltage sources before attempting to install an accessory.
Button Location
Locate the buttons securely to a wall or post.
Be sure the button is not blocked by opened door or cause the user to be in the path of the door leaf when opening.
Check local codes for variations in location requirements.
Another popular type of button has battery-operated transmitters.
They work with a receiver mounted in operator case.
The receiver may be connected to the Control Module for a source of power.
Connect power wires to #12 and #13 for A.C., or #1 and #11 for D.C.
Each transmitter setting must be programmed to same setting of the receiver to
operate correctly.
Per ANSI/BHMA A156.19, switch is to be installed
within view of door at a maximum distance of