Detex AO19 Instructions Manual Download Page 1

DETEX Low Energy Automatic Door Operator, Twin Door-Push (AO19-2

)

104852   Page 1

For device installation videos,

scan code below or

go to www.detex.com/videos

Table of Contents

Device parts breakdown view...............................................................
Parts list................................................................................................
Hardware List with part numbers & tools required................................

Caution notice, Device description........................................................

Inspection, Front cover removal & Hanger plate prep...........................
Hanger plate installation, Opener installation........................................
120VAC connections, Push arm installation..........................................
Motor-Gearbox installation.....................................................................
Door foot installation, Rod Adjustment..................................................

Low voltage connections.......................................................................

Switch description & location.................................................................

Decal description & location...................................................................

Owner's Copy

Page

   2
   3
   4
   4
   5
   6
   7
   8
   9
  10
  11
  12

Detex Corporation,  302 Detex Drive,  New Braunfels,  Texas  78130-3045

830-629-2900  /  800-729-3839  /  Fax 800-653-3839  /  Text photos only: 830-481-6433  /  INTERNET: www.detex.com

104852   September 28, 2020                F

Drawing: 104700

For WARRANTY information,

scan code below or

go to www.detex.com/warranty

Should you have a Question/Problem with your Detex device please call Detex Technical Support

from the job site at 1-800-729-3839 and choose option 2 on our menu. Please do not return the

product to the distributor.

Summary of Contents for AO19

Page 1: ...on Door foot installation Rod Adjustment Low voltage connections Switch description location Decal description location Owner s Copy Page 2 3 4 4 5 6 7 8 9 10 11 12 Detex Corporation 302 Detex Drive New Braunfels Texas 78130 3045 830 629 2900 800 729 3839 Fax 800 653 3839 Text photos only 830 481 6433 INTERNET www detex com 104852 September 28 2020 F Drawing 104700 For WARRANTY information scan co...

Page 2: ...2b 2c 2d 9 2KIT 104852 Page 2 1 6 7 5 4 4 Front cover 10 removed for clarity Push Spline length 1 1 4 Note Push Pull gearbox assemblies are NOT INTERCHANGABLE 8a 8c 8e 8f 8b 8c 8d 8KIT 3a 3b or 3a 3b or 11 ...

Page 3: ...41 1 Nut acorn 3 8 24 Aluminum finish 12741 2 Nut acorn 3 8 24 Bronze finish 12739 1 Screw hex cap 3 8 24 x 1 3 4 long Aluminum finish 12739 2 Screw hex cap 3 8 24 x 1 3 4 long Bronze finish 12735 1 Door foot AO19 Aluminum finish 12735 2 Door foot AO19 Bronze finish 104706 Micro harness AO19 12516 5 12516 6 12516 7 12516 8 Cover AO19 Aluminum finish 74 long not shown Cover AO19 Bronze finish 74 lo...

Page 4: ...idential Commercial and Industrial use If it is to be retrofitted on to an existing door and frame it is important that the door is in good condition and swings freely without restriction It is also important that the header is sturdy and the operator must be fastened securely using the appropriate fasteners less than 300lbs refer to ANSI open and closing speeds All electrical wiring must comply w...

Page 5: ...f cover pull out Remove packing and inspect all items before continuing Receiving Inspection Installation Preparation The hanger plate is unique to the Detex Low Energy Automatic Door Operator It allows the installation to be performed by one person quickly and efficiently 104852 Page 5 Remove the countersunk screws to remove front cover Screws will be re used when re installing cover Unit is ship...

Page 6: ...ger groove tracks can prevent the operator from seating uniformly when mounting Remove debris with thin brush Masking tape can also be used to prevent debris from collecting in groove Lift the operator and lower onto the webs of the hanger plate bracket Be sure both top and bottom are engaged Once they are seated pull down until unit is completely flush and screws can be replaced in top corners 10...

Page 7: ...spection view on page 5 Motors will be marked with a label as either LH PUSH or RH PUSH With the motor end away and slightly below the open edge of the case insert the ASSEMBLY shaft through the hole in the bottom of the case see below Carefully lift and turn the ASSEMBLY into the case being careful not to damage the switch assembly on the top see below Secure the ASSEMBLY to the bottom of the cas...

Page 8: ...ce performed by licensed electrician route thru j box hole 10 32 x 1 2 PPH 1 1 4 dia 203 dia center hole Motor output shaft in full open position Push Arm Installation The UDC 1000 controller must be plugged in and powered up The controls are preset to approximate settings Refer to instruction 104827 Set the toggle switch located at the end of the enclosure to the HOLD position Tighten the screw o...

Page 9: ...8 24 x 1 1 4 Hex Cap Screw P N 12743 1 Al 12743 2 Blk 1 4 20 x 1 Sockethead Cap Screw P N 12742 1 Al 12742 2 Blk 3 8 24 Acorn Nut P N 12741 1 Al 12741 2 Blk Push Arm hardware or some of the hardware is shipped pre assembled Right Hand Push shown Left Hand Push opposite Apply blue thread locker to set screws and tighten to secure the rod Rod Adjustment The arm will rotate to the full open position ...

Page 10: ... holds the cam in place Rotate cam in the closing rotation direction until the Close Speed light turns off and the Latch Speed light turns on Hold the cam in place while gently retightening the holding screw DO NOT OVER TIGHTEN AS THAT WILL DAMAGE THE CAM Test the LATCH CHECK position by manually opening the door leaf until you see Latch Speed light turn off and the Close Speed light turn on This ...

Page 11: ...es before attempting to install an accessory Button Location Locate the buttons securely to a wall or post Be sure the button is not blocked by opened door or cause the user to be in the path of the door leaf when opening Check local codes for variations in location requirements Another popular type of button has battery operated transmitters They work with a receiver mounted in operator case The ...

Page 12: ...ing on a yellow background Final Inspection Before leaving site test all activation devices and time your door To reduce call backs instruct owner on the legal operation of door how to turn on and off function and warranty considerations This operator must be installed serviced by a qualified person The service technician must be familiar with the latest ANSI BHMA A156 10 19 standards Call factory...

Reviews: