Detecto APEX-RI Owner'S Manual Download Page 35

3300-0329-0M Rev C 

y

 apex Portable Scale Owner’s 

29 

BLUETOOTH INTERFACE STANDARD PROTOCOLS 

Bluetooth Characteristic – Weight_Measurement: 0x2A9D 

Widely accepted BLE GATT profiles are used to transmit data to other devices/software that 
have implemented these profiles. Data is passed via BLE using GATT characteristic “Weight 
Measurement” (0x2A9D) as defined by Bluetooth SIG. Refer to the data table below about 
Weight Measurement Characteristics. 
 

Weight_Measurement: 0x2A9D 

 

uint16

uint16

uint8

uint16 

uint16 

uint16 

 0        Not Below Zero 
 1        Below Zero 

 Below Zero 

Summary of Contents for APEX-RI

Page 1: ...3300 0329 0M Rev C y apex Portable Scale Owner s 1 Portable Scale with Remote Indicator Owner s Manual...

Page 2: ...3300 0329 0M Rev C y apex Portable Scale Owner s 2...

Page 3: ...damage to property or injury to persons occasioned from the procedures Persons engaging in the procedures do so entirely at their own risk FCC Compliance Statement This equipment generates uses can ra...

Page 4: ...ironment and to reduce the effects of hazardous substances contained in electrical and electronic equipment on human health Please do your part by making certain that this device is properly disposed...

Page 5: ...SAVER FEATURE Page 8 KEYPAD FUNCTIONS Page 9 ANNUNCIATORS Page 11 OPERATION Page 12 Zero Weight Display Page 12 Basic Weighing Operation Page 12 Body Mass Index BMI Operation Using Previously Measured...

Page 6: ...aracteristic Weight_Measurement 0x2A9D Page 29 Weight_Measurement 0x2A9D Page 29 Custom Services Page 30 Detecto SMA Service 0x907a0000 8699 47dd ab30 d7aad5f83e54 Page 30 SMA Commands Page 30 WI FI A...

Page 7: ...cluded or optional 100 to 240 VAC 50 60Hz 12 VDC 1 A wall plug in UL CSA listed AC power adapter Cardinal part number 6800 1047 Operating Environment Operated Temperature Range 14 to 104 F 10 to 40 C...

Page 8: ...n to minimize lightning damage such as surge suppressors should be installed Electrical Power The Detecto apex Portable Scale with Remote Indicator has been designed to operate from a 100 to 240 VAC 5...

Page 9: ...You should have the following components x Scale Base with attached Display x Scale Base Cover x apex Wall Mount Kit part no 3300 0332 0A which contains a bracket mounting template two screws and two...

Page 10: ...display it should be in a safe area where it will not be in the way of normal traffic The location chosen should be free of temperature extremes water and not in direct sunlight It should be in a loca...

Page 11: ...est will be performed all digits on the weight display will turn on then change to show the software version for a few seconds and finally the display will change to show with the lb annunciator facto...

Page 12: ...Remote Indicator is a device or upstream port and uses readily available cables with the industry standard Micro B connector The USB port may be connected to a computer for transmission of weight and...

Page 13: ...o recharge Battery Status The battery status will be displayed when batteries are installed The battery bar graph on the display indicates the battery capacity in five steps 4 segments the full batter...

Page 14: ...gure No 10 6 If display turns on batteries have been installed correctly If not remove the platform cover and check for one or more improperly positioned batteries 7 The scale is now ready for operati...

Page 15: ...the scale capacity When the weight is removed the display will show a negative weight value Press the 0 key again to reset the display to zero This is the Enter key It serves two purposes First durin...

Page 16: ...ntering the height for BMI calculation pressing and holding the up arrow key key allows you to rapidly increase the height entry Down Arrow During operation the key is used when performing the Body Ma...

Page 17: ...ht samples are greater than the motion limits selected during setup 0 ZERO This annunciator is turned on to indicate that the weight displayed is within 1 4 division of the center of zero LOCK This an...

Page 18: ...stable the STABLE annunciator will turn on 5 The weight reading will automatically lock and the annunciator resembling a padlock will turn on Note that the amount of time the reading will hold is dep...

Page 19: ...baby child assist them back onto the scale 9 When weight is stable the STABLE annunciator will turn on and the baby child s weight will be displayed 10 The weight reading will automatically lock and t...

Page 20: ...current setting prompt will be shown in the smaller upper seven segment display while the value of the current setting will be shown in the large lower seven segment display Note that when moving thr...

Page 21: ...0 XXXXX 1 XXXX X 2 XXX XX 3 XX XXX SAMPLE RATE The display will show 9 and the current setting If the value displayed is acceptable press the key Otherwise press the or keys to select a new value and...

Page 22: ...ed to the next prompt This setting controls the automatic zero tracking of the scale Allowable values are 0 to 10 indicating the number of half divisions above or below zero that the scale will attemp...

Page 23: ...C based EMR electronic medical record software program it will transmit a single set of weight data each time the computer sends a weight request ENQ hex 05 or a SMA weight request W 9 YEAR The displa...

Page 24: ...elect a new value and then press the key to save it and proceed to the next prompt This is the current seconds setting of the real time clock Allowable values are 0 to 59 NOTE The following two parame...

Page 25: ...oceed to the next prompt 0 3 UNLOAD CALIBRATION WEIGHT After a moment the display will change to 0 3 1 Remove the test weights from the scale platform and then press the key 2 Starting at the left and...

Page 26: ...elect i for type in order to use the stand up type scale for the scale with the inline height rod or sonar height rod Allowable settings are i or NOTE If your scale is the Model apex RI C additional s...

Page 27: ...ight request ENQ hex 05 An example and explanation of the data format transmitted is shown below SMA Format 60 or This format is used if the scale is configured for 60 continuous output OR if the scal...

Page 28: ...or the first octet of the static IP address is displayed and then press the key For example if the static IP address is 192 168 0 2 press the or key until the display shows 192 and then press the key...

Page 29: ...of REDBIRD_WIFI_XX XX where XX XX is the last 4 digits of the MAC address Use a Wi Fi device such as a Smartphone tablet or laptop to connect to the apex scale If the connection fails try moving the s...

Page 30: ...to this network each time the scale is turned on Changing the Network Credentials To change the network credentials perform the following steps 1 Press the key to turn the scale on 2 Press and hold th...

Page 31: ...scale is connected to a network you can access the hosted web page To view the web page proceed to the IP address of the Redbird module with webserver html added to it For example if the IP address is...

Page 32: ...weight E Zero Error clears when condition clears space None of the above conditions NOTE For E error condition xxxxxx xxx center dashes and Z O U are overridden r Range 1 2 3 etc always 1 for single r...

Page 33: ...le back on 6 The scale is now ready to pair with a Bluetooth capable device IMPORTANT If an attempt is made to turn the Bluetooth BLE off when a device is connected to the scale the display will show...

Page 34: ...vel 0x180F 0x00 0x64 uint16 represents 0 100 percent READ Weight Scale Service 0x181D Characteristics Number Value s Attributes Weight Measurement 0x2A9D 8bit Flag uint16 weight uint16 bmi uint16 ht S...

Page 35: ...s are used to transmit data to other devices software that have implemented these profiles Data is passed via BLE using GATT characteristic Weight Measurement 0x2A9D as defined by Bluetooth SIG Refer...

Page 36: ...shes the service Characteristics Sub Number Value s Attributes Rx Cmd 0001 SMA string received by scale up to 20 chars WRITE Tx Cmd 0002 SMA string sent by scale up to 20 chars NOTIFY SMA Commands The...

Page 37: ...rors EEPROM error will show an E in the second space and C will show in the third space if there is a calibration error 20 SPACE W request weight 0A570D 0A 5A 31 47 20 20 30 30 30 30 30 30 2E 30 30 6C...

Page 38: ...2 3A 31 0D CAP lb 600 0 2 1 this depends on the settings of the Apex 600 0 Capacity 2 Interval 1 Decimal 3 0A 43 4D 44 3A 48 52 49 4E 58 0D CMD HRINX 4 0A 45 4E 44 3A 0D END 5 If N is sent again you w...

Page 39: ...setting in Setup NOTE If more time is needed press the key to hold the locked weight reading 4 Press the key 5 The scale will then send an output string consisting of the Date Time Weight Height and...

Page 40: ...to the show the software revision for a few seconds 3 Next the display will change to the Weight Display with the 0 ZERO and STABLE annunciators turned on to show a stable center of zero weight condit...

Page 41: ...LE module will be displayed 6 If Wi Fi is enabled 0 the following will be shown a The Wi Fi status Connected or Disconnected 7607 or 3 70 will be displayed b The four octets1 of the static IP address...

Page 42: ...small upper seven segment display and on the large lower seven segment display Note that when the battery voltage drops too low for accurate weighing the scale will automatically shut off and you wil...

Page 43: ...wire brushes abrasives or cleaning tools such as steel pads and scrapers which will scratch the painted surface Instead use soft cloths or plastic scouring pads for cleaning x When possible use treate...

Page 44: ...6680 1043 GROMMET 1 4 ID X 5 8 OD FOR 1 8 TK 7 4 6540 1122 0 81DIA RUBBER FOOT 8 1 3300 0330 0A 72 APEX RI CABLE 9 8 6021 1550 FLAT HEAD CAP SCW M8X1 25X30MM 10 4 6021 0654 PAN HEAD SCW 06 32X 25 11...

Page 45: ...ription 1 1 3300 0042 0A PCB ASS Y 755 CONTROLLER DISPLAY 2 1 3300 0050 08 DISPLAY ENCLOSURE 3 1 3300 0334 0A DISPLAY FRONT APEX RI WITH IMAGE 4 6 3300 0072 08 APEX BUTTONS 5 1 3300 0089 08 UNDERLAY F...

Page 46: ...ing for the freight both ways This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty does...

Page 47: ...nection with the sale or use of the product Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses whether based on tort or c...

Page 48: ...y apex Portable Scale Owner s 42 3300 0329 0M Rev C 02 20 Printed in USA 102 E Daugherty Webb City MO 64870 USA Ph 417 673 4631 or 1 800 641 2008 Fax 417 673 2153 Technical Support 1 866 254 8261 E ma...