Detection Systems
Abacus User Guide
Chapter 4.29
could be because of software variant or panel programming. I.e. Area 1 is displayed as House –
programming of the Area 1 has been changed to House.
When reading the log also read the events in close proximity to each other. I.e. The final exit door was
opened and 20 seconds later the system was unset by Gary, this is the normal recording seen in the log
for the unsetting of the system, two events recorded in the log.
1502 142540 Off
K5 Gary
1502 142520 01A
House Front Door
01 Fx
1502 142015 Off
K4 Ameet
1502 142015 X!
Area 1
1502 103035 On
K7 Gary
The system was
turned Off, by Gary,
using keypad
number 5, on 15
th
February, at 2:25
PM and 40 seconds.
(Noted from event
above) Gary entered
the installation by
the House front door
(Zone 1A) and took
20 seconds to unset
(turn Off) the system
(Noted from event above) Ameet although either a main or master code
user only uns et area 1. Using keypad 4 at 2:20 PM and 15 seconds on the
15
th
of February.
Gary set the installation at 10:30 AM and 35 seconds on 15
th
of February
using keypad 7 (Built in Keypad or remote keypad 7).
With reference below, Gary rearmed all zones that have been omitted
which include zones previously part set but in this case zone 4A the rear
fire door at 8:30 AM and 20 seconds on the 15 of February using keypad 1.
1502 081010 X04A Rear Fire Door
04 24Hr
1502 081010 Off
K1 Main
With reference below, a main code user (no identification programmed)
omitted the rear Fire Door, a 24hr contact on zone 4A, at 8:10 and 10
seconds on the 15 of February using keypad 1.
To save repetition, in the following explanations of the log events, reference to date and time, other log
readings and the keypads used, although recorded have been left out.
1502 081010 Off
Ksw Master
1502 081010 On
Ksw Area 1
1502 081010 X!
Area 2
1502 081010 X03A
Lounge
03 Nite