- Switch 1: “Interval” function selection
(yes or no)
- Switches 2 and 3: Interval time settings
between 4, 8, 12 and 24 hours
- Switches 4 and 5: Humidistat settings
between 60, 70, 80 and 90%
- Switches 6 and 7: Over-run timer
settings between 1, 5, 15 and 30
minutes
- Switch 8: Start-up timer function (yes
or no)
Automatic operation:
The extractor is connected to the main
supply with only two wires. The
humidistat causes the extractor to
operate automatically when the humidity
level in the room is higher than the set
level. The extractor will stop automatically
when the humidity drops below the
selected level (-5% or +10%) and after
the selected period set on the over-run
timer.
"Interval” functions:
This function is useful when the extract
fan is installed in very wet (near the sea)
or the ambiance exceeds the set level for
a very long time. To prevent the fan to run
for hours without stopping, the "Interval"
function allows the fan to switch off
automatically one hour after it began to
run. The extractor keeps switched off
during the set time for interval function. If
the humidity level is still above the set
level when the time interval is over, the
extract fan switches on again and run
during one hour. To select this function
put the dip-switch 1 to position "ON”
To adjust the set time for interval function,
use the dip-switches 2 and 3.
When, on the contrary, the extract fan
never switches on because the humidity
level is always very low or it is improperly
installed (above heating appliance,
behind a door, in an area with no air
movement) putting the 1 dip-switch
interval function to position "ON", the fan
switches on automatically during 1 hour
and then it keeps switched off during the
set time for interval function. This function
causes the fan to run whatever the
humidity level.
To select this function put the dip-switch
1 to position "ON”
To adjust the pre-set time for interval
function, use the dip-switches 2 and 3.
Summary of Contents for SILENT 100 12V
Page 4: ...Deta Smoke Detector Datasheet 4 ...
Page 6: ...Deta Optical Detector User Instructions 6 ...
Page 11: ...Deta Heat Detector User Instruction 11 ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 14: ...14 ...
Page 16: ...Deta CO Detector User Instructions 16 ...
Page 21: ...21 Envirovent 100 document ...
Page 24: ...24 Envirovent 150 document ...
Page 27: ...27 Envirovent 100 and 150 ...
Page 28: ...28 SILENT Instruction leaflet 01 14 ...
Page 29: ...29 Fig 1a Fig 1b 1 2 3 4 5 1 2 3 4 5 6 3 02 14 ...
Page 30: ...30 03 14 Fig 4 Fig 3 Fig 2 L N L N Ls L N L N Ls 4 ...