Range of 100mm domestic axial extract fans for wall or ceiling installations, designed to solve
ventilation problems in WC’s and bathrooms. Fitted with motors mounted on silent elastic
blocks, the fans deliver incredibly silent running and exceptional performance with stylish
features.
Benefits
• Incredibly silent running
• High performance
• Significant energy savings
• Complies with building regulations
Features
• Sealed for life ball bearings
• Silent elastic blocks
• Numerous quality features
• IP45 rated
• SELV version - IP57 rated
• Backdraught shutter and airflow guide
vanes as standard
• Available in silver
• Five year guarantee
ORDER CODE
SIL100S
SIL100T
SIL100IT
SIL100HT
SIL100PIR
SIL100SS
SIL100ST
SIL100S12V
SIL100T12V
SIL100P12V
SIL100TP12V
SIL100HTP12V
Pilot Light
•
•
•
•
•
•
•
•
•
•
Airflow
Guide Vanes
•
•
•
•
•
•
•
•
•
•
•
•
Sealed For Life
Ball Bearings
•
•
•
•
•
•
•
•
•
•
•
•
Silent
Elastic Blocks
•
•
•
•
•
•
•
•
•
•
•
•
Backdraught
Shutter
•
•
•
•
•
•
•
•
•
•
•
•
Adjustable
Timer
•
•
•
•
•
•
Intelligent Timer
- Operates after
50 seconds
•
Adjustable
Humidity
Sensor
•
•
PIR
•
Pullcord
•
•
•
Silver Finish
•
•
Adjustable Timer
After disconnection, the shut off time can
be delayed between 1 and 30 minutes.
This has a factory-set level of 1 minute.
Intelligent Timer
Operates after a 50 second delay.
Thereafter the fan operates automatically.
The ‘run-on’ time is adjustable and can be
set to 5, 20 or 30 minutes.
PIR
Automatically starts up when the fan
detects movement at a maximum of 4
metres.
SELV
(IP57, Class III) specifically designed to
work within the safety area, connected
to remote sited transformers supplied as
standard (CT-12/14) or with an adjustable
timer (CT-12/14H or R).
Adjustable Humidity Sensor
The level of humidity for the bathroom can
be chosen from between 60% and 90%
RH. The extract fan will continue to work
long enough to reach the selected level.
Pullcord
Supplied with pullcord override.
80
01 / 02
Summary of Contents for SILENT 100 12V
Page 4: ...Deta Smoke Detector Datasheet 4 ...
Page 6: ...Deta Optical Detector User Instructions 6 ...
Page 11: ...Deta Heat Detector User Instruction 11 ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 14: ...14 ...
Page 16: ...Deta CO Detector User Instructions 16 ...
Page 21: ...21 Envirovent 100 document ...
Page 24: ...24 Envirovent 150 document ...
Page 27: ...27 Envirovent 100 and 150 ...
Page 28: ...28 SILENT Instruction leaflet 01 14 ...
Page 29: ...29 Fig 1a Fig 1b 1 2 3 4 5 1 2 3 4 5 6 3 02 14 ...
Page 30: ...30 03 14 Fig 4 Fig 3 Fig 2 L N L N Ls L N L N Ls 4 ...