Maintenance Instructions

Instructions for transducerized tools

• Do not damage the wires when pulling out the connectors.

• Do not pull out the torque transducer wires.

• Ensure that wires are not crushed.

Read before maintenance

WARNING Connection Hazard

The tool can start unexpectedly and cause severe bodily injury.

Prior to any maintenance task, disconnect the tool.

Maintenance should be performed by 

qualified personnel only

.

Follow standard engineering practices and refer to exploded views for disassembling and reassembling the different
parts of the system.

Take into account the following instructions given in the exploded views.

Be cautious: when reassembling, tighten the right direction.

Left hand thread

Right hand thread

When reassembling:

Apply the recommended glue.

Tighten to the required torque.

Lubricate with the required grease or oil. Do not apply too much grease on gears or bearings; a thin coat shall be
sufficient.

Preventive Maintenance

Recommendations

Overhaul and preventive maintenance are recommended at regular intervals once per year or after a maximum num-
ber of tightenings (refer to the table below) depending on which occurs sooner.

Heavy duty

Heavy duty use can require more frequent overhaul and Preventive Maintenance intervals. Please contact your local
Desoutter Service team to get a customized maintenance plan.

Upgrading tools

To upgrade tools, it is necessary to have:

• an ACCESS KEY USB stick set with the right profile.

This USB stick is provided by your CVIKEY manager.

• CVIMONITOR software

Contact your Desoutter representative to get more information and support.

Checking before putting back into service

Prior to putting the equipment back into service, check that its main settings have not been modified and that the
safety devices work properly.

Summary of Contents for EID25-1200

Page 1: ...0 EID65 900 6151656170 EID75 800 6151656180 EID120 660 6151656770 EID170 670 6151656780 EID270 410 6151656790 Download the latest version of this document at http www desouttertools com info 615992967...

Page 2: ...unting plate 9 Connecting the tool to the controller 11 Mounting the trigger locker 11 Mounting the front trigger 12 How to install optional accessories 12 Operation 13 Configuration Instructions 13 H...

Page 3: ...the product is first taken into use but will in any case expire at the latest 13 months after delivery Normal wear and tear on parts is not included within the warranty Normal wear and tear is that w...

Page 4: ...2 900 46 37 60 430 EID44 1200 58 48 489 EID65 900 58 48 489 EID75 800 58 48 489 mm A B D M L EID120 660 66 55 48 52 583 EID170 670 76 55 48 66 591 EID270 410 76 67 60 66 625 CAD files For information...

Page 5: ...ED management run reverse mode etc can be set up with CVI CON FIG Change the orientation of the angle head by mounting an eFLEX cable Product description 1 Output drive 2 Trigger 3 Reverse button 4 Re...

Page 6: ...EID120 660 Sq 1 2 EID170 670 Sq 1 2 EID270 410 Sq 3 4 Torque range Nm Model Min Nominal Max EID20 1200 4Q 3 18 20 EID25 1200 3 20 25 EID32 900 5 30 32 EID44 1200 7 40 44 EID65 900 10 60 65 EID75 800 2...

Page 7: ...4 85 10 69 EID270 410 6 35 13 99 Storage and use conditions Storage temperature 20 to 70 C 4 to 158 F Operating temperature 0 to 45 C 32 to 113 F Storage humidity 0 95 RH non condensing Operating humi...

Page 8: ...6155960100 Front trigger 6153978125 eFLEX tool cable Length m Length ft Part number 2 5 8 20 6159176310 5 16 0 6159176320 Service Overview Maintenance program Please consult us on the Tool Care progra...

Page 9: ...ructions From EID20 1200 4Q to EID75 800 From EID120 660 to EID270 410 Dedicated clamping area for torque reaction Preferred clamping area This clamping area can be used as a secondary clamping Do not...

Page 10: ...ether Preferably use the longest length of extension cable and the shortest length of tool cable d D D 10 x d a b c Although our tool cables are designed to work under drastic conditions we recommend...

Page 11: ...ool TOP TOP C A Plug the cable with help of TOP indication Tighten the nut No need to tighten it too much The locking system will prevent any loosening To enable the loosening of the cable actuate the...

Page 12: ...e tool is equipped for example with an open ended Crowfoot head The operator has to press both triggers to start the tool The management of triggers can be set up with CVI CONFIG How to install option...

Page 13: ...this case the tool trigger must be locked by the optional accessory Trigger locker The tightening operation is then triggered by an external start The external start can be a remote pushbutton or a PL...

Page 14: ...ed 2 Green 3 Yellow How to read the tightening report LED color Description Action to do Green Accept report None Yellow Incomplete rundown Tighten again Yellow and red orange Reject report Loosen and...

Page 15: ...ighten to the required torque Lubricate with the required grease or oil Do not apply too much grease on gears or bearings a thin coat shall be sufficient Preventive Maintenance Recommendations Overhau...

Page 16: ...ice EN 16 20 10 2020 Recommissionning Prior to putting the different parts of the system back into service check that the main settings have been correctly set up and that the safety devices work prop...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...cles Off Road General Industry Desoutter offers a comprehensive range of Solutions tools service and projects to meet the specific demands of local and global customers in over 170 countries The compa...

Reviews: