Installation
EN
10 / 20
10/2020
Ensure that the mounting plate thickness is consistent with that indicated in the chapter
Dimensions
.
Use only screws with quality class 12.9.
WARNING Risk Of Electric Shock
The mounting plate where tools are clamped must be
earthed
.
Be sure that the motor is free of motion to enable torque measurement.
Warning: in case of installation in a wheelnut tightening machine, an additional mounting plate must be mounted
next to the output drive.
Read before installing tool cables
Do not connect several extension cables together. Preferably use the longest length of extension cable and the
shortest length of tool cable.
Ød
D
D > 10 x Ø d
a
b
c
Although our tool cables are designed to work under drastic conditions, we recommend that you check the fol-
lowing points for longer service life:
a - Any direct pull on the cable should be avoided.
b - Friction with the outer sheath should be restricted.
c - Bending radii should not be lower than 10 times the cable diameter.
Instructions for cables of fixtured tools
The cable shall not apply any traction to the tool. Any traction force on the cable (even low intensity depending on
the cable orientation) can generate a torque signal on the transducer.
Check the cables are long enough or clamp the tool cable on the frame as shown below.