background image

EN

Operation

10/2020

13 / 20

Operation

Configuration Instructions

How to set up the reverse mode

Go to CVI CONFIG to set up the 

run reverse

 settings.

Refer to the 

Configuration Manual

 of CVI CONFIG (printed matter: 6159925470) available at 

https://

www.desouttertools.com/resource-centre

.

How to set up the tool as a fixtured tool

Desoutter should not be held responsible for any injury, accident or damage which may be the consequence of an in-
correct installation, modification or start-up, or a use out of the intended use of Desoutter products, by the customer
or a third party.

This tool can be used as a fixtured tool installed on a frame in the workstation.

WARNING Risk Of Electric Shock

The frame where tools are clamped must be 

earthed

.

In this case, the tool trigger must be locked by the optional accessory 

Trigger locker

.

The tightening operation is then triggered by an external start.
The external start can be a remote pushbutton or a PLC output signal sent to the controller.

Operating Instructions

Starting the tool

WARNING Risk Of Injury

As the reaction force increases in proportion to the tightening torque, there is a risk of severe bodily injury of the
operator as a result of unexpected behavior of the tool.

Make sure that the tool is in perfect working order and the system is programmed correctly.

Fit the tool with a suitable socket.

Select the appropriate program on the controller.

Hold the tool by means of the handle and apply to the fastener to be tightened.

Press the trigger to start the tool.

How to reverse the rotation

1

Run reverse button

Press this button.

Red and green LEDs are blinking alternatively.

Apply the tool to the fastener and press the trigger.

Summary of Contents for EID25-1200

Page 1: ...0 EID65 900 6151656170 EID75 800 6151656180 EID120 660 6151656770 EID170 670 6151656780 EID270 410 6151656790 Download the latest version of this document at http www desouttertools com info 615992967...

Page 2: ...unting plate 9 Connecting the tool to the controller 11 Mounting the trigger locker 11 Mounting the front trigger 12 How to install optional accessories 12 Operation 13 Configuration Instructions 13 H...

Page 3: ...the product is first taken into use but will in any case expire at the latest 13 months after delivery Normal wear and tear on parts is not included within the warranty Normal wear and tear is that w...

Page 4: ...2 900 46 37 60 430 EID44 1200 58 48 489 EID65 900 58 48 489 EID75 800 58 48 489 mm A B D M L EID120 660 66 55 48 52 583 EID170 670 76 55 48 66 591 EID270 410 76 67 60 66 625 CAD files For information...

Page 5: ...ED management run reverse mode etc can be set up with CVI CON FIG Change the orientation of the angle head by mounting an eFLEX cable Product description 1 Output drive 2 Trigger 3 Reverse button 4 Re...

Page 6: ...EID120 660 Sq 1 2 EID170 670 Sq 1 2 EID270 410 Sq 3 4 Torque range Nm Model Min Nominal Max EID20 1200 4Q 3 18 20 EID25 1200 3 20 25 EID32 900 5 30 32 EID44 1200 7 40 44 EID65 900 10 60 65 EID75 800 2...

Page 7: ...4 85 10 69 EID270 410 6 35 13 99 Storage and use conditions Storage temperature 20 to 70 C 4 to 158 F Operating temperature 0 to 45 C 32 to 113 F Storage humidity 0 95 RH non condensing Operating humi...

Page 8: ...6155960100 Front trigger 6153978125 eFLEX tool cable Length m Length ft Part number 2 5 8 20 6159176310 5 16 0 6159176320 Service Overview Maintenance program Please consult us on the Tool Care progra...

Page 9: ...ructions From EID20 1200 4Q to EID75 800 From EID120 660 to EID270 410 Dedicated clamping area for torque reaction Preferred clamping area This clamping area can be used as a secondary clamping Do not...

Page 10: ...ether Preferably use the longest length of extension cable and the shortest length of tool cable d D D 10 x d a b c Although our tool cables are designed to work under drastic conditions we recommend...

Page 11: ...ool TOP TOP C A Plug the cable with help of TOP indication Tighten the nut No need to tighten it too much The locking system will prevent any loosening To enable the loosening of the cable actuate the...

Page 12: ...e tool is equipped for example with an open ended Crowfoot head The operator has to press both triggers to start the tool The management of triggers can be set up with CVI CONFIG How to install option...

Page 13: ...this case the tool trigger must be locked by the optional accessory Trigger locker The tightening operation is then triggered by an external start The external start can be a remote pushbutton or a PL...

Page 14: ...ed 2 Green 3 Yellow How to read the tightening report LED color Description Action to do Green Accept report None Yellow Incomplete rundown Tighten again Yellow and red orange Reject report Loosen and...

Page 15: ...ighten to the required torque Lubricate with the required grease or oil Do not apply too much grease on gears or bearings a thin coat shall be sufficient Preventive Maintenance Recommendations Overhau...

Page 16: ...ice EN 16 20 10 2020 Recommissionning Prior to putting the different parts of the system back into service check that the main settings have been correctly set up and that the safety devices work prop...