EN
Operation
10/2020
13 / 20
Operation
Configuration Instructions
How to set up the reverse mode
Go to CVI CONFIG to set up the
run reverse
settings.
Refer to the
Configuration Manual
of CVI CONFIG (printed matter: 6159925470) available at
www.desouttertools.com/resource-centre
How to set up the tool as a fixtured tool
Desoutter should not be held responsible for any injury, accident or damage which may be the consequence of an in-
correct installation, modification or start-up, or a use out of the intended use of Desoutter products, by the customer
or a third party.
This tool can be used as a fixtured tool installed on a frame in the workstation.
WARNING Risk Of Electric Shock
The frame where tools are clamped must be
earthed
.
In this case, the tool trigger must be locked by the optional accessory
Trigger locker
.
The tightening operation is then triggered by an external start.
The external start can be a remote pushbutton or a PLC output signal sent to the controller.
Operating Instructions
Starting the tool
WARNING Risk Of Injury
As the reaction force increases in proportion to the tightening torque, there is a risk of severe bodily injury of the
operator as a result of unexpected behavior of the tool.
►
Make sure that the tool is in perfect working order and the system is programmed correctly.
Fit the tool with a suitable socket.
Select the appropriate program on the controller.
Hold the tool by means of the handle and apply to the fastener to be tightened.
Press the trigger to start the tool.
How to reverse the rotation
1
Run reverse button
Press this button.
Red and green LEDs are blinking alternatively.
Apply the tool to the fastener and press the trigger.