Appendix - User info codes _02/2017
- 34 -
Type of
code
Code
no.
Description
Resolution procedure
Error
236
ToolsNet FIFO full
1- The ToolsNet result FIFO is full, the CVINet connection has been lost
2- Check the CVI3 Ethernet cable
3- Check CVI3 Ethernet configuration
4- Check if ToolsNet is running correctly
Error
240
XML not authorized
1- The selected XML protocol is not authorized (check the ePOD
characteristics)
Error
243
PFCS not authorized
1- The selected PFCS protocol is not authorized (check the ePOD
characteristics)
Error
247
XML version conflict
1- Conflict detected in Audi / VW XML protocol version.
2- Check the coherence of the version between the controller and master
PC/PLC
Error
248
SAS order failed
1- Fieldbus SAS order has failed.
2- Check the value of RRGI, SIO, etc.
Error
249
XML PRG 0
1- The PRG value 0 has been set by Fieldbus.
Error
255
Drive choke too hot
1- Power electronics too warm.
2- Let the controller cool down.
Error
256
Motor too hot
1- Tool is locked because its maximum motor temperature has been
reached.
2- Tool will remain locked until the motor temperature comes back to its
normal value.
Error
260
IPM not authorized
1- The selected IPM protocol is not authorized (check the ePOD
connection)
Error
265
Socket(s) usable with more
than one TU
Reconfigure sockets combination to resolve conflicts
Error
268
CVI NET incompatible
CVI Net and CVI3 are incompatible. Please update CVI Net software
Error
502
CVILogix user info
Message generated by CVILOGIX program
Error
890
Device Software Error
Device Software Error
Error
915
Inconsistent version
1- The SW version of all CVI3 controllers must be identical
2- Update firmware
Error
916
Workgroup not authorized
1- You need to connect an epod3 on the Workgroup Primary controller
Error
918
Emergency stop !
1- The emergency stop has been activated
2- Check the M8 connector
Error
919
Additional transducer error
1- The additional transducer's maximum torque is lesser than the
embedded transducer's maximum torque
2- The Pset uses an additional transducer though non is installed on tool
Summary of Contents for CVI3 Function
Page 2: ......
Page 5: ...Table of contents_02 2017 5...
Page 27: ...Appendix I O and events_02 2017 27...
Page 35: ...Appendix User info codes_02 2017 35...
Page 43: ......
Page 44: ...www desouttertools com Copyright 2017 More Than Productivity...