Appendix - User info codes _02/2017
- 30 -
Type of
code
Code
no.
Description
Resolution procedure
Info
242
ToolsNet FIFO alarm
1- The ToolsNet result FIFO has reached alarm threshold, the CVINet
connection has been lost
2- Check the CVI3 Ethernet cable
3- Check CVI3 Ethernet configuration
4- Check if ToolsNet is running correctly
Info
244
Accessory disconnected
1- The accessory at the given address has been disconnected from the
eBUS of the CVI3.
2- Check the accessory cable.
Info
245
Wait report ack
Acknowledge report with its corresponding input
Info
251
No Pset selected
1- No Pset is selected
2- Select a Pset before start order
Info
254
Drive comm. error
1- Error detected in drive communication
2- Restart the controller
3- If the problem occurs again, contact your Desoutter representative for
support
Info
259
Reset input active
1- "Reset" input is active
2- The Tightening Unit will unlock when input switchs to inactive state.
Info
261
Locked by IPM
1- IPM protocol has locked the controller
2- Check the connection with the IPM gateway
3- Check CVI3 IPM configuration
Info
262
OP connect. lost
1- Open protocol connection has been lost
Info
263
Socket tray conflict
For this Tightening Unit, do not associate more than one socket
combination to a Pset
Info
264
Too many steps
Check that an ePOD3 is connected to the controller to enable more steps
per pset
Info
266
Message:
Incoming message received wth dynamic text
Info
269
Pset modified
No procedure
Info
270
Time settings
1-Invalid Time setting
2-Check Pset settings with correct time value settings
Info
271
External tool Pset selected
1- Tool is locked because of External tool Pset selection
Info
272
Debug UsrInfo
1- This UsrInfo is for debug. Contact dev team.
Info
310
Id OK :
1- An identifier has been received and accepted.
2- The identifier is matching an Assembly process start condition
Info
311
Id NOK :
1- An identifier has been received
2- The identifier does not match any Assembly process start condition
Info
312
Access expired
1- The access rights on the USB key cannot be read
2- Unplug the key and insert it again
3- If the issue is persistent, the access right file is probably corrupt
4- Contact your CVI Key administrator.
Info
313
Access invalid
1- The access rights on the USB key could not be read
2- Try unplugg the key and insert it again
3- If the issue is persistent, the access right file is probably corrupt contact
your CVI Key administrator
Info
314
CVIKey plugged
1- an access key has been plugged
Info
315
CVIKey unplugged
1- an access key has been unplugged
Info
316
Barcode lost
no procedure
Info
400
Default Ntwk Cfg
1- Network configuration has been set to default.
Info
401
Ntwk Cfg Error
1- Network configuration failed.
2- Check your settings.
3- If the problem occurs again, contact your Desoutter representative for
support.
Info
500
CVILogix user info
Message generated by CVILOGIX program
Info
888
Controller software updated
no procedure
Info
889
Device Software Updated
Device Software Updated
Info
891
Controller started
No procedure
Info
899
Downgrade not allowed
1- The SW downgrade is not allowed for this version
2- Check the CVI3 image version on your USB key
3- If the update is still failling, contact your Desoutter representative
Info
900
SW update failed
1- The SW upgrade failed
2- Do not remove the USB key and try to restart the CVI3
3- If the upgrade is still failing, contact your Desoutter representative