In connection with the permissible loads on the flanges the following is to be observed:
2
M
calc
M
+
F
calc
F
t
2
2
Where index "calc" are the values calculated by the user.
At the same time none of the forces or moments may exceed the indicated figure multiplied by 1.4.
3. INSTALLATION
See also: DESMI Guidelines for pump installations at:
www.desmi.com/media/sd5ltlox/guidelines_uk.pdf
3.1 MOUNTING/FASTENING
The pump should be mounted and fastened on a solid base plate with a flat and horizontal surface to avoid
distortion.
The max. permissible loads on the flanges stated in paragraph 2.2 are to be observed.
At installations pumping hot or very cold liquids, the operator must be aware that it is dangerous
to touch the pump surface and, consequently, he must take the necessary safety measures.
3.2 WIRING
Wiring to be carried out by authorised skilled workmen according to the rules and regulations in
force.