POSSIBLE CAUSE
1. Control knob not fully
pressed in
2. Control knob not pressed in
long enough
3. Safety interlock system has
been triggered
4. Equipment shutoff valve not
fully open
5. Pilot flame not touching
thermocouple, which allows
thermocouple to cool, caus
-
ing pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
6. Thermocouple connection
loose at control valve
7. Thermocouple damaged
8. Control valve damaged
1. Inlet gas pressure is too
low
2. Burner orifice(s) clogged
3. Mislocated crossover tube
4. Remote selector in OFF
position (Remote-Ready
models only)
5. Wire disconnected from
gas control (Remote-Ready
models only)
1. Manifold pressure is too
low
2. Burner orifice(s) clogged
3. Mislocated crossover tube
1. Burner orifice is clogged or
damaged
2. Damaged burner
3. Gas regulator defective
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep
control knob pressed in 30
seconds
3. Wait one minute for safety
interlock system to reset.
Repeat ignition operation
4. Fully open equipment shut-
off valve
5. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Cleaning and Maintenance
,
page 26) or replace ODS/
pilot assembly
6. Hand tighten until snug,
then tighten 1/4 turn more
7. Replace pilot assembly
8. Replace control valve
1. Contact local natural or
propane/LP gas company
2. C l e a n b u r n e r ( s ) ( s e e
Cleaning and Maintenance
,
page 26) or replace burner
orifice(s)
3. Contact qualified service
person
4. Put remote selector in ON
position
5. S e e
Wi r i n g D i a g r a m
,
page 27
1. Contact local natural or
propane/LP gas company
2. C l e a n b u r n e r ( s ) ( s e e
Cleaning and Maintenance
,
page 26) or replace burner
orifice(s)
3. Contact qualified service
person
1. Clean burner (see
Cleaning
and Maintenance
, page 26)
or replace burner orifice
2. Replace damaged burner
3. Replace gas regulator
OBSERVED PROBLEM
ODS/pilot lights but flame
goes out when control knob
is released
One or both burners do not
light after ODS/pilot is lit
Delayed ignition of one or
both burners
Burner backfiring during
combustion
TROUbLESHOOTING