POSSIBLE CAUSE

1. Ignitor electrode not connected to igni-

tor cable

2. Ignitor cable pinched or wet

3. Piezo ignitor nut is loose

4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode positioned wrong
7. Ignitor electrode broken

1. Gas supply turned off or manual shutoff

valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in PI-

LOT position

4. Air in gas lines when installed

5. ODS/pilot is clogged

6. Gas control setting is not correct

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Manual shutoff valve not fully open
4. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot

5. Thermocouple connection loose at con-

trol valve

6. Thermocouple damaged
7. Gas control damaged

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at ODS/pilot

When ignitor button is pressed, there is
spark at ODS/pilot but no ignition

ODS/pilot lights but flame goes out when
control knob is released

TROUBLESHOOTING

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

3. Tighten nut holding piezo ignitor to base

panel of log set. Nut is located behind
base panel.

4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace ignitor
7. Replace ignitor

1. Turn on gas supply or open manual

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob. Re-

peat igniting operation until air is removed

5. Clean ODS/pilot (see Cleaning and

Maintenance, page 18) or replace ODS/
pilot assembly

6. Replace gas control

1. Press in control knob fully
2. After ODS/pilot lights, keep control

knob pressed in 30 seconds

3. Fully open manual shut-off valve
4. A) Contact local propane gas company

B) Clean ODS/pilot (see Cleaning and
Maintenance
, page 18) or replace ODS/
pilot assembly

5. Hand tighten until snug, then tighten 1/4

turn more

6. Replace thermocouple
7. Replace gas control

Continued

Note:

 For additional help, visit DESA

International’s technical service web site
at 

www.desatech.com

.

Note:

 All troubleshooting items are listed in

order of operation.

www.desatech.com

Summary of Contents for VS18NR

Page 1: ...roperty damage Refer to this manual for cor rect installation and operational proce dures For assistance or additional in formation consult a qualified installer service agency or the gas supplier WAR...

Page 2: ...with a fire placescreeninplace Makesurefireplace screen is closed before running heater 8 This log heater is designed to be smoke less If logs ever appear to smoke turn offheaterandcallaqualifiedservi...

Page 3: ...ed to ANS Z21 11 2 standard for unvented heaters State and local codes in some areas prohibit the use of vent free heaters This heater may also be operated as a vented decorative ANS Z21 60 product by...

Page 4: ...rating of one perm 6x10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to ar...

Page 5: ...ances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr max...

Page 6: ...d Crawl Space To Crawl Space To Attic Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 Ventilation Grills Into Adjoining Room Option 1 12 12 Figure 2 Ventila...

Page 7: ...l codes INSTALLATION CHECK GAS TYPE Use only natural gas If your gas supply is not natural gas do not install heater Call dealer where you bought heater for proper type heater INSTALLATION AND CLEARAN...

Page 8: ...ntel If not using a mantel follow the information below You must have noncombustible material s above the fireplace opening Noncombus tible materials such as slate marble tile etc must be at least 1 2...

Page 9: ...pening Underside of Mantel Shelf Mantel Shelf 12 A 20 241 2 271 2 30 All minimum distances are in inches 2 1 2 6 8 10 Minimum Noncombustible Material 8 Min 12 15 18 All minimum distances are in inches...

Page 10: ...rsarelevel Ifheaterisnotlevel heaterwill not work properly Area of Various Standard Round Flues Diameter ins Area sq ins 5 20 sq inches 6 29 sq inches 7 39 sq inches 8 51 sq inches INSTALLING DAMPER C...

Page 11: ...ed Purchase the optional A G A design certified manual shutoff valve from your dealer See Accessories page 23 Minimum inlet pressure for purpose of input adjustment Figure 13 Gas Connection Tee Joint...

Page 12: ...ts individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where manual shutoff valve was connected 3...

Page 13: ...ure 16 Push back of logs flush with metal grate bar Note 18 model has only one front log 2 Rest bottom middle log 2 behind metal posts on front burner Make sure the grooves in the bottom of the log fi...

Page 14: ...re to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not us...

Page 15: ...em etc For wall thermostat operation follow in struction supplied with thermostat acces sory GWMT1 For wall switch operation followinstructionssuppliedwithGWMS2 OPTIONAL REMOTE OPERATION NOTICE You mu...

Page 16: ...Off with the Hand Held Remote Unit Figure 24 Thermostat Hand Held Remote Control Unit Selections GHRCT only The log heater will automatically cycle between pilot and the heat setting that has been se...

Page 17: ...e pattern Theincorrectpilotflameisnottouch ing the thermocouple This will cause the thermocouple to cool When the thermo couple cools the heater will shut down If pilot flame pattern is incorrect as s...

Page 18: ...ware store or home center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the direc tions on the can If you don t f...

Page 19: ...D PROBLEM When ignitor button is pressed there is no spark at ODS pilot When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob...

Page 20: ...en using furniture polish wax carpet cleaners or similar products 1 Replace 9 volt batteries in receiver and remote control OBSERVED PROBLEM One or both burners do not light after ODS pilot is lit Del...

Page 21: ...SIBLE CAUSE 1 Metal expanding while heating or con tracting while cooling 1 Heater burning vapors from paint hair spray glues cleaners chemicals new carpet etc See IMPORTANT state ment above 2 Low fue...

Page 22: ...r TECHNICAL SERVICE You may have further questions about in stallation operation or troubleshooting If so contact DESA International s Technical Service Department at 1 800 DESA LOG 1 800 337 2564 You...

Page 23: ...LL MOUNT ON OFF SWITCH GWMS2 Not Shown For all models Allows the gas log heater to be turned on and off with a wall switch WALL MOUNT THERMOSTAT SWITCH GWMS1 Not Shown For all models The desired comfo...

Page 24: ...URAL GAS LOG HEATER DESA INTERNATIONAL ILLUSTRATED PARTS BREAKDOWN VARIABLE CONTROL CFS18NR VS18NR VS24NR VS30NR 8 9 10 11 8 8 12 13 23 14 26 27 6 6 16 19 31 21 22 29 30 17 24 20 15 28 18 10 1 10 2 6...

Page 25: ...271 03 Ignitor Cable 1 14 102445 01 102445 01 102445 01 Piezo Ignitor 1 15 103588 01 103588 01 103588 01 Heat Shield 1 16 103782 01 103782 01 103782 01 Valve Bracket 1 17 M12461 26 M12461 26 M12461 26...

Page 26: ...such other costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EX...

Reviews: