www.desatech.com
111035-01F
0
LIGHTING
INSTRUCTIONS
WARNING:
• If fireplace has glass doors,
never operate this heater with
glass doors closed. If you op
-
erate heater with doors closed,
heat buildup inside fireplace
will cause glass to burst. Make
sure there are no obstructions
across openings of fireplace.
• You must operate this heater
with a fireplace screen in
place. Make sure fireplace
screen is closed before run
-
ning heater.
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be pres
-
ent. Open damper or window to
vent smell. This will only last a
few hours.
Note:
Home owners generally prefer to op-
erate their heater with the chimney damper
closed. This will put all the heat into the room.
However, there may be times you will desire
the full flames of the HI heat setting but will
find the heat output excessive. You can open
the chimney damper (if you have one) fully or
partially to release some of the heat.
WARNING: Damper handle
will be hot if heater has been
running.
1. STOP! Read the safety information, page
19, column 2.
2. Remove control cover log (see Figure 30).
3. Make sure equipment shutoff valve is fully
open.
4. Press in and turn control knob clockwise
to the OFF position.
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information, page 19, column 2. If
you don’t smell gas, go to the next step.
6. Slightly depress and turn control knob
counterclockwise
to the PILOT
position. Keep control knob pressed in for
five (5) seconds (see Figure 31).
Note:
You may be running this heater for
the first time after hooking up to gas sup
-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the burner. If need-
ed, keep pressing ignitor button until pilot
lights.
Note:
If pilot does not light, contact
a qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure
, page 21.
8. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 3
through 7.
9. Slightly depress and turn control knob
counterclockwise
to the HI position.
The burner should light. Set control knob
to any heat level between HI and LO.
10. To leave pilot lit and shut off burners only,
turn control knob clockwise
to the
HI position then press in and turn clockwise
to PILOT position.
11. Replace control cover log (see Figure 31).
OPERATING HEATER
Continued
Figure 30 - Control Knob and Ignitor
Button Location
Control
Knob
Ignitor
Button
Control
Cover
Log