![Desa VDL18PR Owner'S Operation And Installation Manual Download Page 22](http://html.mh-extra.com/html/desa/vdl18pr/vdl18pr_owners-operation-and-installation-manual_2485975022.webp)
www.desatech.com
111035-01F
O
F
F
P
ILO
T
LO
IH
ON
Control Cover
Log
LIGHTING
INSTRUCTIONS
WARNING:
• If fireplace has glass doors,
never operate this heater with
glass doors closed. If you op
-
erate heater with doors closed,
heat buildup inside fireplace
will cause glass to burst. Make
sure there are no obstructions
across openings of fireplace.
• You must operate this heater
with a fireplace screen in
place. Make sure fireplace
screen is closed before run
-
ning heater.
NOTICE: During initial operation of
new heater, burning logs will give
off a paper-burning smell. Orange
flame will also be present. Open
damper or window to vent smell.
This will only last a few hours.
Note:
Home owners generally prefer to op-
erate their heater with the chimney damper
closed. This will put all the heat into the room.
However, there may be times you will desire
the full flames of the HI heat setting but will
find the heat output excessive. You can open
the chimney damper (if you have one) fully or
partially to release some of the heat.
WARNING: Damper handle will
be hot if heater has been running.
WARNING: Burners will come
on automatically within one
minute when the control valve
is in the ON position after the
pilot is lit.
1. STOP! Read the safety information, page
21, column 2.
2. Make sure equipment shutoff valve is fully
open.
3. Remove control cover log (see Figure 32).
4. Press in and turn control knob clockwise
to the OFF position (see Figure 32).
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information, page 21, column 2. If
you don’t smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise
to the PILOT position.
Press in control knob for five (5) seconds
(see Figure 32).
Note:
You may be running this heater for
the first time after hooking up to gas sup
-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note:
If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure
, page 23.
8. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob coun-
terclockwise
to the ON position.
10. Set flame adjustment knob to any level
between HI and LO.
OPERATING HEATER
Continued
Figure 32 - Control Knob (Shown in the
OFF Position) and Ignitor Button Location
Flame
Adjustment
Knob
Control
Knob
Ignitor Button
O
F
F
P
ILO
T
LO
IH
ON