background image

www.desatech.com

116035-01J

4

3.  Never install the fireplace 

• in a recreational vehicle
• in windy or drafty areas where curtains 

or other combustible (flammable) objects 
can  make  contact  with  the  fireplace 
front

• in high traffic areas

4.  Turn  fireplace  off  and  let  cool  before 

servicing,  installing  or  repairing.  Only  a 
qualified  service  person  should  install, 
service or repair this fireplace. Have fire

-

place  inspected  annually  by  a  qualified 
service person.

5.  You  must  keep  control  compartments, 

burners  and  circulating  air  passages 
clean.  More  frequent  cleaning  may  be 
needed  due  to  excessive  lint  and  dust 
from  carpeting,  bedding  material,  etc. 
Turn off the gas valve and pilot light before 
cleaning fireplace.

6.  Have venting system inspected annually by 

a qualified service person. If needed, have 

SAFETy

Continued

PRODUCT IDENTIFICATION

Figure 1 - Top and Rear Direct-Vent Fireplaces

Rear Vent 
Flue Collar

Nailing 
Flange

Top Vent 
Flue Collar

Door Latch

Log Set

Ember 
Tray

Junction 
Box

Lower Louver Panel

Control Valve Variable 
Input Adjustment

Piezo Ignitor with 
Optional Remote and 
Blower Control Mount

Upper 
Louver 
Panel

Glass Door 
Assembly

LOCAL CODES

venting system cleaned or repaired. See 

Cleaning and Maintenance

, page 38.

7.  Do not use any solid fuels (wood, coal, 

paper,  cardboard,  etc.)  in  this  fireplace. 
Use only the gas type indicated on fire

-

place nameplate.

8.  This appliance, when installed, must be 

electrically grounded in accordance with 
local  codes  or,  in  the  absence  of  local 
codes, with the 

National Electrical Code, 

ANSI/NFPA 70.

9.  Do not use fireplace if any part has been 

exposed to or under water. Immediately 
call a qualified service person to arrange 
for replacement of the unit.

10. Do  not  operate  fireplace  if  any  log  is 

broken.

11. Do not operate fireplace with glass door 

removed, cracked or broken.

12. Provide adequate clearances around air 

openings.

Install and use fireplace with care. Follow all 
local  codes. In the absence  to local  codes, 
use the current 

National Fuel Gas Code ANSI 

Z223.1/NFPA 54*

 (USA).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Summary of Contents for (V) CD36T(N

Page 1: ...of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any...

Page 2: ...is owner s manualcarefullyandcompletely before trying to assemble op erate or service this fireplace Improper use of this fireplace cancauseseriousinjuryordeath from burns fire explosion electrical sh...

Page 3: ...rtible for use with other gases unless a certified kit is used WARNING Donotallowfans toblowdirectlyintothefireplace Avoidanydraftsthatalterburner flame patterns Safety Continued Due to high temperatu...

Page 4: ...ver Panel Control Valve Variable Input Adjustment Piezo Ignitor with Optional Remote and Blower Control Mount Upper Louver Panel Glass Door Assembly Local Codes venting system cleaned or repaired See...

Page 5: ...atches or lighters Models V CD36RE TE are equipped with an electronic ignition system that requires 120VAC to operate An electrode ignitor automatically lights the pilot flame when the fireplace is tu...

Page 6: ...h treatments Remove the shrink wrap securing the 2 carton trays to the unit Lift the top carton tray off and remove the four corner posts Discard the bottom tray once the unit is moved into position N...

Page 7: ...4 10 25 4 cm C 8 20 3 cm 5 8 20 3 cm D 6 15 2 cm 6 4 10 1 cm F 4 10 1 cm 7 2 5 1 cm G 2 5 1 cm Figure 7 Clearances for Combustible Mantels MANTEL CLEARANCES Figure 7 shows projected mantel depths at v...

Page 8: ...15 3 8 39 cm 35 3 4 90 8 cm 2 5 cm 25 63 5 cm TO CENTER OF 8 REAR VENT 37 94 cm TO NAILING FLANGE 4 1 2 11 4 cm ELECTRICAL INLET 8 20 3 cm GAS SUPPLY INLET 36 3 4 93 4 cm 36 1 4 92 1 cm TO NAILING FL...

Page 9: ...000 and 50 000 12 30 cm in Canada if between 10 000 and 100 000 12 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada...

Page 10: ...ly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEEP...

Page 11: ...C direct vent pipe components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or g...

Page 12: ...and twist one section clockwise approximately one quarter turn until sections are fully locked see Figure 11 Note Horizontal runs of vent must be sup ported every three feet Use wall straps for this...

Page 13: ...ior wall with wood screws provided see Figure 14 Siding standoff must sit flush against exterior fascia material 7 Connecting Vent Cap with Horizontal Vent Pipe Fit outer and inner wall firestop into...

Page 14: ...igurations and alternatives for venting with horizontal termination Each figure includes a chart with critical minimum and maximum dimensions which MUST be met IMPORTANT If using a venting configurati...

Page 15: ...nation Configuration with Vertical Rise and One 90 Elbow Model V CD36T Required Vertical V Vertical V Vertical Pipe Allowable Horizontal H 45 1 2 None 26 Max 57 1 4 Min 1 ft 30 Max 69 1 4 Min 2 ft 74...

Page 16: ...r a horizontal system using two 90 elbows Figure 24 Horizontal Termination Configuration For Venting Using Two 90 Elbows Model V CD36T Venting with Two 90 Elbows Vertical V Horizontal H Horizontal H2...

Page 17: ...ions V CD36T Series Only When installing the OSR58 30 offset it must be turned 20 off center line see Figure 27 page 18 This will give you the 1 clearance to horizontal framing members that are a mini...

Page 18: ...stop below framed hole If area above is an attic or insulated area install firestop above framed hole Note If an offset is needed to avoid obstruc tions you must support vent pipe every 3 feet Use wal...

Page 19: ...High Wind Termination Venting with Two 90 Elbows Vertical V1 Horizontal H1 Vertical V1 Vertical V2 Horizontal H Horizontal H2 8 Min 2 Max 12 Min 8 Max 8 Min 2 Max 14 Min 11 Max 8 Min 2 Max 16 Min 14 M...

Page 20: ...Max 9 Min 11 Max 10 Min 13 Max 12 Min 17 Max 14 Min 20 Max Venting with Three 90 Elbows Vertical V Horizontal H1 Horizontal H2 8 Min 5 Max 10 Min 8 Max 12 Min 11 Max 14 Min 14 Max 16 Min 17 Max 18 Mi...

Page 21: ...Flashing 0 6 6 12 26 Screws VKC 58 Corner Vent Kit Galvanized Includes 45 Elbow 7 12 Adjustable Pipe Wall Firestop Horizontal Square Termination 6 Pipe 90 Elbow 18 Screws HHTK 58 High Wind Round Hori...

Page 22: ...ting tab back through notch as before 7 Slide the junction box down till mounting tab holes line up and replace the inner retaining screw 8 With junction box cover removed pull the end of 3 wire Romex...

Page 23: ...nd turning lock nut with pliers clockwise until it is tight against front panel Place control knob provided on shaft 7 Turn on power to duplex outlet if previ ously turned off per the warning in colum...

Page 24: ...ed slightly to allow enough wire length to reach and make all connections DO NOT trim excessive length away Just enable enough to make all con nections securely 3 Place blower against lower rear wall...

Page 25: ...h gwmS2 1 Connect one terminal of 25 ft wire for wall switch to TPTH terminal on valve Connect remaining wire terminal to TH terminal on valve Make sure wire termi nals are in positions on unit as pic...

Page 26: ...ver on back of remote control unit 2 Attach terminal wires to a 9 volt alkaline battery not included Place battery into battery housing 3 Replace battery cover onto remote control unit Figure 47 Insta...

Page 27: ...see Accessories page 52 Installing Gas Piping to Fireplace Location WARNING A qualified service person must connect fireplace to gas supply Follow all local codes CAUTION For propane LP units never co...

Page 28: ...ified Equipment Shutoff Valve with 1 8 NPT Tap 3 Minimum Approved Flexible Gas Line Cap Pipe Tee Nipple Joint Sediment Trap Drip Leg Natural From Gas Meter 5 5 W C to 10 5 W C Pressure Propane LP From...

Page 29: ...ral gas fireplace or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Retighten all fittings 5 If...

Page 30: ...glass door panel securely in place For replacementpartinformationsee Replacement Parts page 45 CAUTION Wear gloves and safety glasses while handling or removingbrokenglass Donotre moveifglassishot Ke...

Page 31: ...lease tension on door frame see Figure 58 4 Unhook locking clasp from tabs on door frame With both hands swing door panel out while pivoting lower frame on lower retaining bracket 5 Lift lower frame t...

Page 32: ...ny part of the control system and any gas control which has been under water Figure 61 Control Valve P I LOT O F F PILO T O N TPTH TP TH HI LO IN OUT Gas Control Knob Variable Control Knob Piezo Ignit...

Page 33: ...29 MANUAL LIGHTING PROCEDURE 1 Remove glass door see Removing Re placing Glass Door page 30 2 Follow steps 1 through 8 under Lighting Instructions page 32 3 Press gas control knob and light pilot with...

Page 34: ...mote Control Unit HRC200 LOCK MANU AUTO C F TEMP POWER ROOM TEMP SET TEMP AUTO Turns Hand Held Remote On or Off and Allows You to Choose the Manual Setting Selects AUTO Mode C F Mode Button Locks Syst...

Page 35: ...ON position 11 Visually locate the pilot The ignitor should begin to spark and the main burner should ignite once flame appears at pilot Figure 65 Turning Equipment Shutoff Valve to the OFF Position...

Page 36: ...thermostat has been electronically cali brated at the factory and requires no adjust ment or leveling Upon installation thermostat must be allowed to stabilize at room temperature for a mini mum of 30...

Page 37: ...stallation and performance Figure 68 shows a typical flame pattern If burner flame pattern differs from that de scribed turn fireplace off see To Turn Off Gas to Appliance page 33 or 36 depending on m...

Page 38: ...remove excess dust dirt or lint WARNING Turn off fireplace and let cool before cleaning CAUTION You must keep control areas burners and circulating air passageways of fireplace clean Inspect these are...

Page 39: ...IVOLT IGNITION POSSIBLE CAUSE 1 Ignitor electrode not con nected to ignitor cable 2 Ignitor cable pinched or wet 3 Piezo ignitor nut is loose 4 Broken ignitor cable 5 Bad piezo ignitor 6 Ignitor elect...

Page 40: ...place control valve 1 Clean burner see Cleaning and Maintenance page 38 or replace burner orifice 2 Contact local propane LP or natural gas company 3 Reconnect leads to TP and TPTH terminals on contro...

Page 41: ...ne Have gas line checked by local propane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 38 or replace burner orifice 1 Adjust the log set so the flame does not excessively...

Page 42: ...off in use Gas odor even when control knob is in OFF position Gas odor during combustion Darkresidueonlogsorinside of fireplace REMEDY 1 Locate and correct all leaks see Checking Gas Connections page...

Page 43: ...tions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pilot line 6 Replacecontrolvalve Referto Replacement Parts page 45 7 Check that main power is on and that wire...

Page 44: ...noise just after burner is lit or shut off Slight smoke or odor during initial operation Gas odor even when control knob is in OFF position Glass soots Dark residue on logs or inside of fireplace Remo...

Page 45: ...37 5 cm Flanges and Standoffs Not Included in Measurement Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Conta...

Page 46: ...www desatech com 116035 01J 46 Parts FIREPLACE ASSEMBLY FOR MODELS V CD36RN V CD36RP V CD36TN V CD36TP V CD36RN HA V CD36TN HA 1 2 8 10 9 1 1 12 3 16 5 6 7 13 19 1 4 1 3 2 4 14 15 17 18 11...

Page 47: ...2 Firebox Assembly Complete NG 1 Firebox Assembly Complete NG 1 Firebox Assembly Complete LP 1 Firebox Assembly Complete LP 1 13 110973 01 Cover Junction Box 2 14 24460 Gas Conduit Assembly 2 15 21171...

Page 48: ...www desatech com 116035 01J 48 PARTS BURNER ASSEMBLY FOR MODELS V CD36RN V CD36RP V CD36TN V CD36TP V CD36RN HA V CD36TN HA 1 2 3 5 20 9 18 11 10 19 12 6 7 17 13 14 16 15 4 8...

Page 49: ...Burner Orifice 44 1 26482 Burner Orifice 55 1 6 26808 Valve Bracket 1 7 24389 Tube 3 8 Dia x 11 Aluminum 1 8 24360 Pilot Bracket 1 9 14500 Fitting 3 8 MPT x 1 2 Flare 1 10 14399 Fitting Brass Elbow 3...

Page 50: ...www desatech com 116035 01J 50 PARTS BURNER ASSEMBLY FOR MODELS V CD36RNE V CD36RPE V CD36TNE V CD36TPE 8 5 9 11 30 16 28 18 17 29 15 12 13 26 19 20 23 22 10 14 27 4 21 6 29 24 7 25 1 2 3...

Page 51: ...ontrol Valve Millivolt 1 16 14500 Fitting 3 8 MPT x 1 2 Flare 1 17 14399 Fitting Brass Elbow 3 8 MPT x 3 8 Comp Tube 1 18 14396 Fitting Brass Straight 3 8 MPT x 3 8 Comp Tube 1 19 14299 Air Shutter 1...

Page 52: ...HRC200 SERIES Allows fireplace to be operated manually or thermostatically controlled mode You can adjust your heat settings and turn the fireplace on or off without leaving the comfort of your easy...

Page 53: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 54: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 55: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 56: ...ed as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repair...

Reviews: