background image

www.desatech.com

113110-01H

6

ASSEMBLy

Continued

Figure 3 - Assembling Hood

Hood Tab

Sheet Metal 

Screws

Louver

Baffle

Firebox Top

Hood

Hood Tabs

AIR FOR COMBUSTION AND VENTILATION

 WARNING: This heater shall 

not  be  installed  in  a  room  or 

space unless the required vol

-

ume  of  indoor  combustion  air 

is provided by the method de

-

scribed in the 

National Fuel Gas 

Code, ANSI Z223.1/NFPA 54,

 the 

International Fuel Gas Code,

 or 

applicable local codes. Read the 

following instructions to insure 

proper  fresh  air  for  this  and 

other  fuel-burning  appliances 

in your home.

Today’s homes are built more energy efficient 
than ever. New materials, increased insula

-

tion,  and  new  construction  methods  help 
reduce  heat  loss  in  homes.  Home  owners 
weather strip and caulk around windows and 
doors to keep the cold air out and the warm air 
in. During heating months, home owners want 

their homes as airtight as possible.
While it is good to make your home energy 

efficient, your home needs to breathe. Fresh 

air must enter your home. All fuel-burning ap-
pliances need fresh air for proper combustion 
and ventilation.

Exhaust fans, fireplaces, clothes dryers, and 
fuel burning appliances draw air from the house 
to operate. You must provide adequate fresh 

air for these appliances. This will insure proper 

venting of vented fuel-burning appliances.

PROVIDING ADEQUATE 
VENTILATION

The following are excerpts from 

National Fuel 

Gas  Code,  ANSI  Z223.1/NFPA  54,  Air  for 
Combustion and Ventilation

.

All spaces in homes fall into one of the three 

following ventilation classifications:

1.  Unusually Tight Construction

2.  Unconfined Space
3.  Confined Space
The information on pages 6 through 8 will help 

you classify your space and provide adequate 
ventilation.

Unusually Tight Construction

The air that leaks around doors and windows 

may provide enough fresh air for combustion 

and ventilation. However, in buildings of un

-

usually tight construction, you must provide 

additional fresh air.

Unusually tight construction is defined as 

construction where:

a.  walls and ceilings exposed to the out

-

side  atmosphere  have  a  continuous 
water vapor retarder with a rating of one 
perm (6 x 10

-11

 kg per pa-sec-m

2

) or less 

with openings gasketed or sealed 

and

b.  weather stripping has been added on 

openable windows and doors 

and

7.  Gently  rotate  hood  to  upright  position. 

Make sure hood tabs are behind louvers 

and  hood  is  resting  on  firebox  top  (see 
Figure 3,).

8.  Align  screw  holes  on  hood  with  screw 

holes on firebox top.

9.  Insert screws as shown in Figure 3, page 

6. Tighten screws firmly.

Summary of Contents for Unvented (Vent-Free) Gas Compact Classic Hearth Fireplace VMH26NRB

Page 1: ...al switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire departmen...

Page 2: ...s appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from...

Page 3: ...the OFF position to prevent children from turning on burners with remote You must operate this fireplace withthefireplacescreeninplace Make sure fireplace screen is closed before running fireplace Ke...

Page 4: ...that can be purchased separately wall switch hand held ON OFF remote wall thermostat hand held thermostat remote See Accessories page 35 Local Codes Install and use fireplace with care Follow all loca...

Page 5: ...udes one hardware packet Assembly Local Codes Continued 4 Check fireplace for any shipping dam age If heater is damaged call DESA Heating LLC at 1 866 672 6040 for replacement parts before returning t...

Page 6: ...from the house to operate You must provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are e...

Page 7: ...th x Width x Height __________cu ft volume of space Example Space size 16 ft length x 14 ft width x 8 ft ceiling height 1792 cu ft volume of space AIR FOR COMBUSTION AND VENTILATION Continued If addit...

Page 8: ...adjoining room see option 3 Figure 4 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts AIR FOR COMBUSTION AND V...

Page 9: ...clearance installations Wall or framing ma terial can be placed directly against any exterior surfaceontherear sides ortopofyourfireplace except where standoff spacers are integrally at tached If stan...

Page 10: ...in Figure 6 Example The face of a mantel bookshelf etc is made of combustible material and protrudes 3 1 2 from the wall This com bustible material must be 4 from the side of the fireplace opening se...

Page 11: ...lve The flexible gas line must be the last item installed on the gas piping Nails or Wood Screws Nailing Flanges Figure 9 Attaching Fireplace to Wall Studs Wall Studs 4 If you have not assembled fireb...

Page 12: ...ollowing raise the mantel to an accept able height remove the mantel Figure 10 Minimum Mantel Clearances for Built In Installation OPTIONAL MANTEL Installation Refer to instructions provided with the...

Page 13: ...shoulder screws Align fireplace in mantel assembly so the trim overlaps mantel evenly on all three sides 12 Lower bottom louver door Use 3 wood screws provided with mantel accessory to attach fireplac...

Page 14: ...oles in the rear of the valve cover shieldandthroughtherectangularholeinthe front of shield see Figure 16 page 15 8 Reconnect red wire to switch position 3 Reconnect blue wire to switch position 1 Rec...

Page 15: ...tch Plate Blue Red Valve Cover Shield Snap Bushing Black Blower Mounting Holes Lower Louver Door Power Cord Figure 17 Wiring Diagram For Blower Accessory Standard Installation Red Red Fan Switch Auto...

Page 16: ...t In Installation WARNING A licensed elec trician must connect the wiring harness to electrical supply followingalllocalcodes Electri cianmustprovideaclamponthe box cover to secure the wiring Wiringsh...

Page 17: ...f you do not reduce incoming gas pressure fireplace regulator damage could occur Install external regula tor with the vent pointing down as shown in Figure 21 Pointing the vent down protects it from f...

Page 18: ...te sediment trap where it is within reach for cleaning Install in piping system between fuel supply and heater Locate sediment trap where trapped matter is not likely to freeze Asediment trap traps mo...

Page 19: ...flame to check for a leak Apply a noncorrosive leak detection fluid toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION Make sure exter nal regulator has been installed betweenprop...

Page 20: ...e Figure 28 Discard switch plate after removing Save the screws 4 Locate battery clip mounted on back of receiver see Figure 29 5 Slide 9 volt battery not included through the clip 6 Attach terminal w...

Page 21: ...side of base see Figure 33 WARNING Do not con nect the thermostat to a power source Electrical shock and or a fire hazard will occur 6 Connect one bare wire end to each terminal W and R of the thermos...

Page 22: ...see Figure 32 page 21 2 Connect remaining wire terminal to TH terminal on control valve Make sure that wire terminals are in the positions on your unit as pictured in Figure 32 page 21 If wires are n...

Page 23: ...this fireplace with the fireplace screen in place Make sure fire place screen is installed before running fireplace Figure 36 Control Knob and Ignitor Button Location Shown as Supplied No Control Opt...

Page 24: ...e the selector switch is in the OFF positionwhenyouareawayfrom home for long periods of time Fireplacewillcomeonautomati cally with selector switch in the ON position TO TURN OFF GAS TO APPLIANCE Shut...

Page 25: ...rol 2 Press MANU button to turn on fireplace 3 Press POWER and LOCK buttons to gether to turn off fireplace Auto Thermostatic Mode 1 Press POWER and LOCK buttons together to turn on hand held remote c...

Page 26: ...red setting Thermostat has been electronically calibrated at the factory and requires no adjustment or leveling Upon installation thermostat must be allowed to stabilize at room temperature for a mini...

Page 27: ...liance page 24 see Troubleshooting page 30 Note The pilot flame on natural gas units will have a slight curve but flame should be blue and have no yellow or orange color BURNER FLAME PATTERN Figure 45...

Page 28: ...re hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could dam age...

Page 29: ...remove one piece log set for clean ing refer to Installing Log Set and Screen page 22 for placement instructions Replace log set if broken or chipped dime sized or larger CABINET Air Passageways Use...

Page 30: ...in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignit...

Page 31: ...trol knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas compa...

Page 32: ...ne checked by local natural gas company 3 Observe minimum instal lation clearances see page 10 4 Clean burner see Cleaning and Maintenance page 28 or replace burner orifice 1 Turn fireplace off when u...

Page 33: ...each your gas supplier call the fire department IMPORTANT Operating fireplace where impurities in air exist may create odors Cleaning supplies paint paint remover cigarette smoke cements and glues new...

Page 34: ...t s call DESA Heating LLC at 1 866 672 6040 When calling DESA Heating LLC have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually...

Page 35: ...Unfinished Traditional Design W26TO Oak Finished Traditional Design W26GO Oak Finished Georgian Design Mantel features clean classic lines Available in a stained oak or unfinished hardwood ready to s...

Page 36: ...atech com 113110 01H 36 Parts MODELS VMH26PRB and VMH26NRB 39 37 38 4 22 40 32 11 28 30 12 7 35 25 10 9 7 23 1 2 20 20 8 14 8 24 33 34 13 41 21 26 18 15 27 20 3 20 29 16 18 3 17 42 36 6 4 20 19 31 31...

Page 37: ...01 Injector 1 20 M11084 26 Screw Hex Head 10 x 3 8 25 21 098249 01 Nut M5 6 22 103781 01 Gas Valve 1 103781 02 Gas Valve 1 23 102639 01 Baffle 1 24 101628 01 Flexible Connector 1 25 104305 01 Control...

Page 38: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 39: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 40: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Reviews: