 CAUTION: This heater cre-

ates  warm  air  currents.  These 

currents move heat to wall sur-

faces  next  to  heater.  Installing 

heater next to vinyl or cloth wall 

coverings  or  operating  heater 

where impurities (such as, but 

not limited to, tobacco smoke, 

aromatic candles, cleaning flu-

ids, oil or kerosene lamps, etc.) in 

the air exist, may discolor walls 

or cause odors.

IMPORTANT:

 Vent-free heaters add moisture 

to the air. Although this is beneficial, installing 
heater  in  rooms  without  enough  ventilation 
air may cause mildew to form from too much 

moisture. See 

Air for Combustion and Ventila-

tion

, page 6.

CHECK GAS TYPE

Use only the correct gas type (natural or pro-
pane/LP) for your unit. If your gas supply is not 

correct, do not install heater. Call dealer where 

you bought heater for proper type heater.

 WARNING: This appliance is 

equipped for either natural gas 

or propane/LP gas but not both. 

Gas type is indicated on the rat-

ing plate. Field conversion is not 

permitted.

INSTALLATION AND CLEARANCES 
(Vent-Free Operation Only)

  WARNING:  Maintain  the 

minimum  clearances.  If  you 

can, provide greater clearances 

from floor, ceiling and adjoining 

wall.

MINIMUM FIREPLACE CLEARANCE 

TO COMBUSTIBLE MATERIALS

Side Wall 16", Ceiling 42", Front 36"

Carefully follow the instructions below. This 
will ensure safe installation into a masonry, 
UL127-listed manufactured fireplace or certi

-

fied vent-free firebox.

MINIMUM CLEARANCES FOR SIDE 
COMBUSTIBLE MATERIAL, SIDE WALL 
AND CEILING 

A.  Clearances from the side of the fireplace 

cabinet to any combustible material and 

wall should follow diagram in Figure 4.

 

Example:

 The face of a mantel, bookshelf, 

etc. is made of combustible material and 
protrudes 3 

1

/

2

" from the wall. This com

-

bustible material must be 4" from the side 
of the fireplace cabinet (see Figure 4).

 

Note: When installing your gas logs into 

a  manufactured  firebox,  follow  firebox 

manufacturer’s instructions for minimum 
clearances to combustible materials.

B.  Clearances from the top of the fireplace 

opening to the ceiling should not be less 

than 42".

NOTICE: Manual control heaters 

may be used as a vented product. 

If so, you must always run heater 

with chimney flue damper open. 

If  running  heater  with  damper 

open, noncombustible material 

above fireplace opening is not 

needed. Go to 

Installing Damper 

Clamp  Accessory  for  Vented 

Operation

, page 11.

Figure 4 - Minimum Clearance for 

Combustible to Wall

*Minimum 16" from Side Wall

*

Example

INSTALLATION

Continued

LOG SIZING REQUIREMENTS

Minimum Firebox Size

Height 17", Depth 13", Front Width 28", 

Rear Width* 20.5"

*Measured at 13" Depth

Summary of Contents for HDL18N

Page 1: ...cal switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire departme...

Page 2: ...vented gas fired heat er It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation...

Page 3: ...nt even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any change to thi...

Page 4: ...l operation slight smok ing could occur due to log curing and heater burning manufacturing residues 10 To prevent the creation of soot follow the instructions in Cleaning and Maintenance page 19 11 Be...

Page 5: ...s sembly The data plates contain important warranty and safety information 1 Remove logs and heater base assembly from carton Note Do not pick up heater base assem bly by burners This could damage hea...

Page 6: ...ight construction you must provide additional fresh air Unusually tight construction is defined as construction where a walls and ceilings exposed to the out side atmosphere have a continuous water va...

Page 7: ...an the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an un...

Page 8: ...ation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo stat controlled power vent Heated air entering the att...

Page 9: ...RANCE TO COMBUSTIBLE MATERIALS Side Wall 16 Ceiling 42 Front 36 Carefully follow the instructions below This will ensure safe installation into a masonry UL127 listed manufactured fireplace or certi f...

Page 10: ...is not required see Figure 6 Figure 6 Minimum Mantel Clearances Without Using Hood Determining Minimum Mantel Clearance when Using a Hood If minimum clearances in Figure 6 are not met you must have a...

Page 11: ...to combustibles see Figure 8 B If combustible materials are less than 14 to the fireplace you must install appliance at least 5 above the combustible flooring see Figure 9 INSTALLING DAMPER CLAMP ACC...

Page 12: ...eater control panel This will in sure adequate air flow and guard against sooting and controls be ingdamaged Raisefireplacefloor with noncombustible material Make sure material is secure CAUTION Do no...

Page 13: ...lregu lator not supplied Install the external regulator between the heater and propane LP supply WARNING For natural gas units never connect heater to private non utility gas wells This gas is commonl...

Page 14: ...ible Gas Hose if allowed by local codes Natural From Gas Meter 5 W C to 10 5 W C Pressure Propane LP From External Regulator 11 W C to 14 W C Pressure We recommend that you install sediment trap in su...

Page 15: ...m by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter nat...

Page 16: ...will fit over burner see Figure 18 Holes in bottom of log must seat over pins on base as shown in Figure 18 Make sure back of log as Figure 18 Installing Main Log 1 Back Tab Burner Front Tab Notch for...

Page 17: ...to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING If fireplace has glass doors never operate this heater with glass doors closed If...

Page 18: ...tern Pilot Burner Thermocouple Pilot Burner Thermocouple Inspecting Burners Check pilot flame pattern and burner flame patterns often PILOT FLAME PATTERN Figure 22 shows a correct pilot flame pattern...

Page 19: ...to excessive lint from carpeting bedding material pet hair etc WARNING Failure to keep the primary air opening s of theburner s cleanmayresultin sooting and property damage Once every year a qualifie...

Page 20: ...ile in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM When control knob is pres...

Page 21: ...or propane LP gas company 1 Contact local natural or propane LP gas company 2 Clean burner see Cleaning and Maintenance page 19 or replace burner orifice 1 Clean burner see Cleaning and Maintenance pa...

Page 22: ...burner until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see page 9 4 Clean burner see Cleaning and Maintenance...

Page 23: ...see Checking Gas Con nections page 14 1 Open window and or door for ventilation 2 Contact local natural or propane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 19 1 Locate and c...

Page 24: ...www desatech com 122493 01C 24 Parts MODELS hdl18 n p vdb18 n p 1 18 19 2 16 4 15 15 8 9 11 21 5 12 3 10 17b 17c 17a 14 7 6...

Page 25: ...Burner Inlet Tube 1 9 108188 02 Screw Type U Drive 2 x 0 75 1 10 108134 01 NG Plate 1 11 099056 26 Injector 1 099056 19 Injector 1 12 099387 08 Pilot Tube 1 13 098249 01 ODS Nut 2 14 M11084 38 Screw H...

Page 26: ...eating LLC have ready model number of your heater the replacement part number Technical Service You may have further questions about instal lation operation or troubleshooting If so con tact DESA Heat...

Page 27: ...n Street Kansas City MO 64108 KS MO AR 816 842 3911 www washerparts com East Coast Energy Products 10 East Route 36 W Long Branch NJ 07764 732 870 8809 1 800 755 8809 www njplaza com ecep 21st Century...

Page 28: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Reviews: