background image

www.desatech.com

122493-01C

17

OPERATION

FOR YOUR SAFETY  

READ BEFORE LIGHTING

 WARNING: If you do not fol-

low  these  instructions  exactly, 

a  fire  or  explosion  may  result 

causing property damage, per-

sonal injury or loss of life.

A.  This appliance has a pilot which must 

be  lighted  by  hand.  When  lighting 
the  pilot,  follow  these  instructions 
exactly.

B.  BEFORE  LIGHTING  smell  all  around 

the appliance area for gas. Be sure to 
smell next to the floor because some 
gas is heavier than air and will settle 
on the floor.

 

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 
gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn 

the gas control knob. Never use tools. 
If the knob will not push in or turn by 
hand, don’t try to repair it, call a quali-
fied service technician or gas supplier. 
Force or attempted repair may result in 
a fire or explosion.

D.  Do  not  use  this  appliance  if  any  part 

has been under water. Immediately call 
a qualified service technician to inspect 
the appliance and to replace any part of 
the control system and any gas control 
which has been under water.

LIGHTING 

INSTRUCTIONS

 WARNING

•  If  fireplace  has  glass  doors, 

never operate this heater with 

glass doors closed. If you op-

erate heater with doors closed, 

heat  buildup  inside  fireplace 

will cause glass to burst. Make 

sure there are no obstructions 

across openings of fireplace.

•  You must operate this heater 

with a fireplace screen in place. 

Make sure fireplace screen is 

closed before running heater.

NOTICE: During initial operation 

of new heater, burning logs will 

give off a paper-burning smell. 

Orange flame will also be pres-

ent. Open damper or window to 

vent smell. This will only last a 

few hours.

Note: Home owners generally prefer to oper-
ate their heater with chimney damper closed. 
This will put all of the heat into room. However, 

there may be times you will desire full flames 
of  HI  heat  setting  but  will  find  heat  output 

excessive.  You  can  open  chimney  damper 
(if you have one) fully or partially to release 
some heat.

  WARNING:  Damper  handle 

will  be  hot  if  heater  has  been 

running.

1.  STOP!  Read  the  safety  information, 

column 1.

2.  Make sure equipment shutoff valve is fully 

open.

3.  Press in and turn control knob clockwise 

 to the OFF position.

4.  Wait five (5) minutes to clear out any gas. 

Then  smell  for  gas,  including  near  the 
floor. If you smell gas, STOP! Follow “B” 
in the safety information, column 1. If you 
don’t smell gas, go to the next step.

Summary of Contents for HDL18N

Page 1: ...cal switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire departme...

Page 2: ...vented gas fired heat er It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation...

Page 3: ...nt even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any change to thi...

Page 4: ...l operation slight smok ing could occur due to log curing and heater burning manufacturing residues 10 To prevent the creation of soot follow the instructions in Cleaning and Maintenance page 19 11 Be...

Page 5: ...s sembly The data plates contain important warranty and safety information 1 Remove logs and heater base assembly from carton Note Do not pick up heater base assem bly by burners This could damage hea...

Page 6: ...ight construction you must provide additional fresh air Unusually tight construction is defined as construction where a walls and ceilings exposed to the out side atmosphere have a continuous water va...

Page 7: ...an the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an un...

Page 8: ...ation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo stat controlled power vent Heated air entering the att...

Page 9: ...RANCE TO COMBUSTIBLE MATERIALS Side Wall 16 Ceiling 42 Front 36 Carefully follow the instructions below This will ensure safe installation into a masonry UL127 listed manufactured fireplace or certi f...

Page 10: ...is not required see Figure 6 Figure 6 Minimum Mantel Clearances Without Using Hood Determining Minimum Mantel Clearance when Using a Hood If minimum clearances in Figure 6 are not met you must have a...

Page 11: ...to combustibles see Figure 8 B If combustible materials are less than 14 to the fireplace you must install appliance at least 5 above the combustible flooring see Figure 9 INSTALLING DAMPER CLAMP ACC...

Page 12: ...eater control panel This will in sure adequate air flow and guard against sooting and controls be ingdamaged Raisefireplacefloor with noncombustible material Make sure material is secure CAUTION Do no...

Page 13: ...lregu lator not supplied Install the external regulator between the heater and propane LP supply WARNING For natural gas units never connect heater to private non utility gas wells This gas is commonl...

Page 14: ...ible Gas Hose if allowed by local codes Natural From Gas Meter 5 W C to 10 5 W C Pressure Propane LP From External Regulator 11 W C to 14 W C Pressure We recommend that you install sediment trap in su...

Page 15: ...m by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter nat...

Page 16: ...will fit over burner see Figure 18 Holes in bottom of log must seat over pins on base as shown in Figure 18 Make sure back of log as Figure 18 Installing Main Log 1 Back Tab Burner Front Tab Notch for...

Page 17: ...to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING If fireplace has glass doors never operate this heater with glass doors closed If...

Page 18: ...tern Pilot Burner Thermocouple Pilot Burner Thermocouple Inspecting Burners Check pilot flame pattern and burner flame patterns often PILOT FLAME PATTERN Figure 22 shows a correct pilot flame pattern...

Page 19: ...to excessive lint from carpeting bedding material pet hair etc WARNING Failure to keep the primary air opening s of theburner s cleanmayresultin sooting and property damage Once every year a qualifie...

Page 20: ...ile in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM When control knob is pres...

Page 21: ...or propane LP gas company 1 Contact local natural or propane LP gas company 2 Clean burner see Cleaning and Maintenance page 19 or replace burner orifice 1 Clean burner see Cleaning and Maintenance pa...

Page 22: ...burner until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see page 9 4 Clean burner see Cleaning and Maintenance...

Page 23: ...see Checking Gas Con nections page 14 1 Open window and or door for ventilation 2 Contact local natural or propane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 19 1 Locate and c...

Page 24: ...www desatech com 122493 01C 24 Parts MODELS hdl18 n p vdb18 n p 1 18 19 2 16 4 15 15 8 9 11 21 5 12 3 10 17b 17c 17a 14 7 6...

Page 25: ...Burner Inlet Tube 1 9 108188 02 Screw Type U Drive 2 x 0 75 1 10 108134 01 NG Plate 1 11 099056 26 Injector 1 099056 19 Injector 1 12 099387 08 Pilot Tube 1 13 098249 01 ODS Nut 2 14 M11084 38 Screw H...

Page 26: ...eating LLC have ready model number of your heater the replacement part number Technical Service You may have further questions about instal lation operation or troubleshooting If so con tact DESA Heat...

Page 27: ...n Street Kansas City MO 64108 KS MO AR 816 842 3911 www washerparts com East Coast Energy Products 10 East Route 36 W Long Branch NJ 07764 732 870 8809 1 800 755 8809 www njplaza com ecep 21st Century...

Page 28: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Reviews: