background image

www.desatech.com

113900-01D

 

WARNING:  Improper 

installation,  adjustment, 

alteration,  service  or 

maintenance  can  cause 

injury  or  property  dam

-

age. Refer to this manual 

for  correct  installation 

and  operational  proce

-

dures.  For  assistance  or 

additional  information 

consult  a  qualified  in

-

staller, service agency or 

the gas supplier.

 

WARNING:  For  use 

only  with  a  listed  gas-

fired  unvented  decora-

tive  room  heater.  Not  to 

exceed 40,000 Btu/Hr. Do 

not build a wood fire.

IMPORTANT: Read this owner’s 

manual carefully and completely 

before  trying  to  assemble,  op

-

erate  or  service  this  firebox. 

Improper use of this firebox can 

cause  serious  injury  or  death 

from burns, fire, explosion, elec

-

trical shock or carbon monoxide 

poisoning.

 

WARNING:  Any  change  to 

this firebox or its controls can 

be dangerous.

 WARNING: Do not use a blow

-

er  insert,  hood,  heat  exchanger 

insert or other accessory not ap

-

proved for use with this heater.

 WARNING: Do not allow fans 

to blow directly into the firebox. 

Avoid any drafts that alter burner 

flame patterns. Ceiling fans can 

create  drafts  that  alter  burner 

flame  patterns.  Altered  burner 

patterns can cause sooting.

Due  to  high  temperatures,  the 

firebox should be located out of 

traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable  material  on  or  near 

firebox. Never place any objects 

on the firebox or logs.

Firebox  front  and  screen  be

-

come  very  hot  when  running 

firebox.  Keep 

children  and 

adults away from hot surfaces to 

avoid burns or clothing ignition. 

Firebox will remain hot for a time 

after shutdown. Allow surfaces 

to cool before touching.

Carefully supervise young chil

-

dren when they are in the room 

with firebox.

SAFETY INFORMATION

TABLE OF CONTENTS

Safety Information ............................................... 
Local Codes......................................................... 3
Unpacking............................................................ 3
Product Features ................................................. 4
Locating Firebox  ................................................. 4
Air For Combustion and Ventilation ..................... 4
Installation ........................................................... 7

Technical Service............................................... 13
Replacement Parts ............................................ 13
Accessories ....................................................... 14
Parts Centrals .................................................... 15
Illustrated Parts Breakdown and Parts List........ 16
Warranty Information ...........................Back Cover

Summary of Contents for HDFB32C

Page 1: ...y ANSI Z21 11 2 ap proved gas logs This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This appliance is only for use wi...

Page 2: ...ith this heater WARNING Donotallowfans to blow directly into the firebox Avoidanydraftsthatalterburner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner pat...

Page 3: ...o not use the firebox if it has been un der water due to the shock hazard that could result with the blower accessary if installed in place 11 Provide adequate clearances around air openings SAFETY IN...

Page 4: ...nsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods hel...

Page 5: ...ome meets all of the three criteria above you must provide additional fresh air See Ventilation Air From Outdoors page 6 If your home does not meet all of the three criteria above proceed to Determini...

Page 6: ...s water heater ___________ Btu Hr Gas furnace ___________ Btu Hr Vented gas heater ___________ Btu Hr Gas fireplace logs ___________ Btu Hr Other gas appliances _________ Btu Hr Total _ ________ Btu H...

Page 7: ...ge 12 Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Co...

Page 8: ...uchorextendbeyond the fireplace screen If your installation does not meet the mini mum clearances in Figure 7 you must raise the mantel to an acceptable height OR remove the mantel Example Figure 6 Mi...

Page 9: ...front panel pushing the plastic control shaft forward through the opening see Figure 10 INSTALLation Continued 3 While supporting speed control secure control shaft with lock nut by pushing and turnin...

Page 10: ...pickuplog base assembly by burners This could damage burners Only handle base by grates CAUTION Donotremovethe dataplatesattachedtotheheater base assembly The data plates contain important warranty an...

Page 11: ...d with mantel As sembly instructions are included with each accessory 2 If using a blower install a properly grounded 120 volt three prong electrical outlet at firebox location if an outlet is not the...

Page 12: ...ll 39 3 8 27 7 8 55 5 8 34 3 4 Figure 19 Rough Opening for Installing in Corner 34 3 4 17 3 4 33 1 Frame in rough opening Use dimensions shown in Figure 18 for the rough opening If installing in a cor...

Page 13: ...lappingthefront facing with noncombustible facing material Technical Service You may have further questions about instal lation operation or troubleshooting If so contact DESA Heating Products Technic...

Page 14: ...ings fluted sides and medallion Accessories Purchase these fireplace accessories from your local dealer If they can not supply these accessories call DESAHeating Products Sales Department at 1 866 672...

Page 15: ...and Rapids MI 49504 2672 616 791 0505 1 800 446 1446 www nbmc com Parts Centrals These Parts Centrals are privately owned businesses They have agreed to support our customer s needs by providing origi...

Page 16: ...www desatech com 113900 01D 16 5 14 14 21 13 14 6 1 14 7 14 18 12 12 20 8 16 11 15 17 9 4 2 3 2 14 10 15 19 Illustrated Parts Breakdown HDFB32C...

Page 17: ...rick Retainer 3 3 114042 01 Rear Firebrick 1 4 114042 02 Side Firebrick 2 5 103207 01 Outer Casing 1 6 Outer Shell Base 1 7 Firebox Wrapper 1 8 103297 01 Assembly Screen 2 9 103773 05 Front Assembly 1...

Page 18: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 19: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 20: ...inal condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnos...