background image

www.desatech.com

113900-01D

13

INSTALLATION

Continued 

Figure 20 - Attaching Firebox to Wall Studs 

Nailing 
Flanges

Nails or 
Wood 
Screws 

 

Actual 

Framing

Height 

3

/

16

33"

Front Width  

34 

5

/

16

34 

3

/

4

"

Depth 

16 

11

/

16

17 

3

/

4

"

8.  Check  all  gas  connections  for  leaks.  See 

Checking  Gas  Connections

  in  log  set 

owner’s manual. 

9.  If using optional perimeter kit, install the 

trim  after  final  finishing  and/or  painting 
of  wall.  See  instructions  included  with 
perimeter  trim  accessory  for  attaching 
perimeter trim.

IMPORTANT: 

When  finishing  your  firebox, 

combustible  materials  such  as  wall  board, 
gypsum board, sheet rock, drywall, plywood, 
etc. may be butted up next to the sides and top 
of the firebox. Combustible materials should 
never overlap the firebox front facing.

 WARNING: Do not allow any 

combustible materials to overlap 

the firebox front facing. 

IMPORTANT

: Noncombustible materials such 

as brick, tile, etc. may overlap the front facing, 
but should never cover any necessary open-
ings like louvered slots.

  WARNING:  Do  not  allow 

noncombustible  materials  to 

cover any necessary openings 

like louvered slots.

  WARNING:  Use  only  non

-

combustible  mortar  or  adhe

-

sives when overlapping the front 

facing  with  noncombustible 

facing material.

TECHNICAL SERVICE

You may have further questions about instal-
lation,  operation  or  troubleshooting.  If  so, 
contact  DESA  Heating  Products’  Technical 
Service Department at 1-866-67-6040. When 
calling  please  have  your  model  and  serial 
numbers of your heater ready.
You can also visit DESA Heating Products’ Tech-
nical Service web site at 

www.desatech.com.

REpLACEMENT pARTS

Note:

  Use  only  original  replacement  parts. 

This will protect your warranty coverage for 
parts replaced under warranty. 

PARTS UNDER WARRANTY

Contact  authorized  dealers  of  this  product 
or 

Parts Central

 (see page 15). If they can’t 

supply original replacement part(s), call DESA 
Heating  Products’ Technical  Service  Depart-
ment at 1-866-67-6040.
When  calling  DESA  Heating  Products,  have 
ready
•  your name
•  your address
•  model  and  serial  numbers  of  your  fire-

place

•  how fireplace was malfunctioning
•  type  of  gas  used  (propane/LP  or  natural 

gas)

•  purchase date
Usually, we will ask you to return the part to 
the factory.

PARTS NOT UNDER WARRANTY

Contact  authorized  dealers  of  this  product 
or 

Parts Central

 (see page 15). If they can’t 

supply original replacement part(s), call DESA 
Heating Products at 1-866-67-6040 for refer-
ral information.
When  calling  DESA  Heating  Products,  have 
ready
•  model number of your fireplace 
•  the replacement part number

Summary of Contents for HDFB32C

Page 1: ...y ANSI Z21 11 2 ap proved gas logs This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This appliance is only for use wi...

Page 2: ...ith this heater WARNING Donotallowfans to blow directly into the firebox Avoidanydraftsthatalterburner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner pat...

Page 3: ...o not use the firebox if it has been un der water due to the shock hazard that could result with the blower accessary if installed in place 11 Provide adequate clearances around air openings SAFETY IN...

Page 4: ...nsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods hel...

Page 5: ...ome meets all of the three criteria above you must provide additional fresh air See Ventilation Air From Outdoors page 6 If your home does not meet all of the three criteria above proceed to Determini...

Page 6: ...s water heater ___________ Btu Hr Gas furnace ___________ Btu Hr Vented gas heater ___________ Btu Hr Gas fireplace logs ___________ Btu Hr Other gas appliances _________ Btu Hr Total _ ________ Btu H...

Page 7: ...ge 12 Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Co...

Page 8: ...uchorextendbeyond the fireplace screen If your installation does not meet the mini mum clearances in Figure 7 you must raise the mantel to an acceptable height OR remove the mantel Example Figure 6 Mi...

Page 9: ...front panel pushing the plastic control shaft forward through the opening see Figure 10 INSTALLation Continued 3 While supporting speed control secure control shaft with lock nut by pushing and turnin...

Page 10: ...pickuplog base assembly by burners This could damage burners Only handle base by grates CAUTION Donotremovethe dataplatesattachedtotheheater base assembly The data plates contain important warranty an...

Page 11: ...d with mantel As sembly instructions are included with each accessory 2 If using a blower install a properly grounded 120 volt three prong electrical outlet at firebox location if an outlet is not the...

Page 12: ...ll 39 3 8 27 7 8 55 5 8 34 3 4 Figure 19 Rough Opening for Installing in Corner 34 3 4 17 3 4 33 1 Frame in rough opening Use dimensions shown in Figure 18 for the rough opening If installing in a cor...

Page 13: ...lappingthefront facing with noncombustible facing material Technical Service You may have further questions about instal lation operation or troubleshooting If so contact DESA Heating Products Technic...

Page 14: ...ings fluted sides and medallion Accessories Purchase these fireplace accessories from your local dealer If they can not supply these accessories call DESAHeating Products Sales Department at 1 866 672...

Page 15: ...and Rapids MI 49504 2672 616 791 0505 1 800 446 1446 www nbmc com Parts Centrals These Parts Centrals are privately owned businesses They have agreed to support our customer s needs by providing origi...

Page 16: ...www desatech com 113900 01D 16 5 14 14 21 13 14 6 1 14 7 14 18 12 12 20 8 16 11 15 17 9 4 2 3 2 14 10 15 19 Illustrated Parts Breakdown HDFB32C...

Page 17: ...rick Retainer 3 3 114042 01 Rear Firebrick 1 4 114042 02 Side Firebrick 2 5 103207 01 Outer Casing 1 6 Outer Shell Base 1 7 Firebox Wrapper 1 8 103297 01 Assembly Screen 2 9 103773 05 Front Assembly 1...

Page 18: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 19: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 20: ...inal condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnos...

Reviews: