www.desatech.com
111115-01F
1
inStALLAtion
Continued
FLOOR CLEARANCES
A. If installing appliance on the floor level, you
must maintain the minimum distance of 14"
to combustibles (see Figure 8).
B. If combustible materials are less than 14" to
the fireplace, you must install appliance at
least 5" above the combustible flooring (see
Figure 9).
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
14"
Min.
Combustible
Material
Noncombustible Material
Hearth
5"
Min.
Combustible
Material
Area of Various Standard
Round Flues
Diameter
Area
5"
0 sq. inches
6"
9 sq. inches
"
39 sq. inches
8"
51 sq. inches
Chimney
Minimum permanent
Height
Flue Opening
6' to 15'
39 sq. inches
15' to 30'
9 sq. es
Figure 10 - Attaching Damper Clamp
Damper
Clamp
Damper
Manufactured
Fireplace
Masonry Fireplace
Damper
Damper
INSTALLING DAMpER CLAMp
ACCESSORY FOR VENTED
OpERATION
Note:
When used as a vented heater, appliance
must be installed only in a solid-fuel burning
fireplace with a working flue and constructed of
noncombustible material.
If your heater is a manually controlled model, you
may use this heater as a vented product. There
are three reasons for operating your heater in the
vented mode:
1. The fireplace does not meet the clearance
to combustibles requirements for vent-free
operation
2. State or local codes do not permit vent-free
operation
3. You prefer vented operation
If reasons number 1 or 2 above apply to you, you
must permanently open chimney flue damper. You
must install the damper clamp accessory (to order,
see
Accessories
, page 29). This will insure vented
operation (see Figure 10). The damper clamp will
keep damper open. Installation instructions are
included with clamp accessory.
See chart below for minimum permanent flue
opening you must provide. Attach damper clamp
so the minimum permanent flue opening will be
maintained at all times.