SERVICE HINTS
When Gas pressure Is Too Low
•. pilot.will.not.stay.lit
•. burners.will.have.delayed.ignition
• heater will not produce specified heat
•. propane/LP.gas.supply.may.be.low
You.may.feel.your.gas.pressure.is.too.low..If.
so, contact your local propane/LP or natural
gas.supplier.
SPECIFICATIONS
VGC18PR/EC18PR/VCC18PR
• Rating (Variable): 24,000/30,000 Btu/Hr
• Type Gas: Propane/LP
•. Ignition:.Electronic
•. Manifold.Pressure:.7.9".W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
*For.purpose.of.input.adjustment
VGC18NR/EC18NR/VCC18NR
• Rating (Variable): 21,000/30,000 Btu/Hr
• Type Gas: Natural
•. Ignition:.Electronic
•. Manifold.Pressure:.3.".W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For.purpose.of.input.adjustment
VGC24PR/EC24PR/VCC24PR
• Rating (Variable): 28,000/39,000 Btu/Hr
• Type Gas: Propane/LP
•. Ignition:.Electronic
•. Manifold.Pressure:.7.9".W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
*For.purpose.of.input.adjustment
VGC24NR/EC24NR/VCC24NR
• Rating (Variable): 28,000/39,000 Btu/Hr
• Type Gas: Natural
•. Ignition:.Electronic
•. Manifold.Pressure:.3.".W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For.purpose.of.input.adjustment
VGC30PR/EC30PR/VCC30PR
• Rating (Variable): 28,000/39,000 Btu/Hr
• Type Gas: Propane/LP
•. Ignition:.Electronic
•. Manifold.Pressure:.7.9".W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
*For.purpose.of.input.adjustment
VGC30NR/EC30NR/VCC30NR
• Rating (Variable): 28,000/39,000 Btu/Hr
• Type Gas: Natural
•. Ignition:.Electronic
•. Manifold.Pressure:.3.".W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For.purpose.of.input.adjustment
TECHNICAL SERVICE
You.may.have.further.questions.about.instal-
lation, operation or troubleshooting. If so, con
-
tact DESA Heating, LLC at 1-866-672-6040.
When. calling. please. have. your. model. and.
serial.numbers.of.your.heater.ready.
You can also visit DESA Heating, LLC’s web
site.at.
www.desatech.com
.
REPLACEMENT PARTS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
pARTS UNDER WARRANTY
Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call DESA Heating, LLC at 1-866-672-6040.
When calling DESA Heating, LLC, have
ready
•. your.name
•. your.address
•. model.and.serial.numbers.of.your.heater.
•. how.heater.was.malfunctioning
•. type. of. gas. used. (propane/LP. or. natural.
gas)
•. purchase.date
Usually, we will ask you to return the part to
the.factory.
pARTS NOT UNDER WARRANTY
Contact authorized dealers of this product.
If. they. can’t. supply. original. replacement.
part(s), call DESA Heating, LLC at 1-866-
672-600. for. referral. information..A. list. of.
authorized dealers can be found by visiting
www.desatech.com
.
When calling DESA Heating, LLC, have
ready
•. model.number.of.your.heater.
•. the.replacement.part.number