background image

15

103413

OWNER’S MANUAL

INSTALLATION

Continued

 CAUTION: Do not pick up log

base assembly by burners. This
could damage burners. Only
handle base by grates.

Figure 31 - Removing Log Base Assembly
From Fireplace

3.

Route flexible gas line (provided by
installer) from manual shutoff valve to
fireplace. Route flexible gas supply line
through one of the access holes.

4.

Attach a 45˚ flare union gas connector
to flexible gas line from gas supply (see
Figure 32). Connect flare union to flex-
ible gas line attached to gas regulator
of fireplace (see Figure 32).

5.

Check all gas connections for leaks. See
Checking Gas Connections, below.

6.

Replace log base assembly back into
fireplace. Feed flexible gas line into
fireplace base area while replacing log
base assembly. Make sure the entire
flexible gas line is in fireplace base
area. Reattach log base assembly to fire-
place with screws removed in step 2.

NOTICE : Most building codes do
not permit concealed gas con-
nections. A flexible gas line is
provided to allow accessibility
from the fireplace. The flexible
gas supply line connection to the
manual shutoff valve should be
accessible.

Flexible Gas Line
from Fireplace Gas
Regulator (Provided
with Fireplace)

To Fireplace
Gas Regulator

Gas Connector

Flexible Gas
Line from
Manual Shutoff
Valve (Provided
by Installer)

Manual
Shutoff Valve

To
Gas
Meter

Figure 32 - Attaching Flexible Gas Lines
Together

CHECKING GAS
CONNECTIONS

 WARNING: Test all gas pip-

ing and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.

 WARNING: Never use an open

flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. Bubbles forming
show a leak. Correct all leaks at
once.

Pressure Testing Gas Supply
Piping System

Test Pressures In Excess Of 1/2 PSIG

1.

Disconnect fireplace and its individual
manual shutoff valve from gas supply
piping system. Pressures in excess of 1/2
psig will damage fireplace gas regulator.

Continued

CONNECTING FIREPLACE
TO GAS SUPPLY

Installation Items Needed

•  5/16" hex socket wrench or nut-driver

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not

provided)

1.

Remove fireplace screen. Remove two
screws that hold fireplace screen in
place for shipping. These screws are
located near top of screen. Discard
screws. Lift fireplace screen up and pull
out to remove.

2.

Remove screws that attach log base
assembly to fireplace (see Figure 31).
Carefully lift up log base assembly and
remove from fireplace (see Figure 31).

2.

Cap off open end of gas pipe where
manual shutoff valve was connected.

3.

Pressurize supply piping system by ei-
ther using compressed air or opening
main gas valve located on or near gas
meter.

4.

Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

6.

Reconnect fireplace and manual shutoff
valve to gas supply. Check reconnected
fittings for leaks.

Test Pressures Equal To or Less Than
1/2 PSIG

1.

Close manual shutoff valve (see Fig-
ure 33).

2.

Pressurize supply piping system by ei-
ther using compressed air or opening
main gas valve located on or near gas
meter.

3.

Check all joints from gas meter to
manual shutoff valve (see Figure 34).
Apply mixture of liquid soap and wa-
ter to gas joints. Bubbles forming show
a leak.

4.

Correct all leaks at once.

Figure 34 - Checking Gas Joints

Manual Shutoff Valve

 Gas Valve

Gas
Meter

Figure 33 - Manual Shutoff Valve

ON

POSITION

OFF

POSITION

Open

Closed

Manual
Shutoff
Valve

Summary of Contents for Comfort Glow CGFP28N

Page 1: ...ualified installer service agency or the gas supplier WARNING Improperinstallation adjustment alteration service ormaintenancecancauseinjury orpropertydamage Refertothis manual for correct installatio...

Page 2: ...on logs 17 Fireplace front and screen becomes very hot when running fireplace Keep children and adults away from hot sur faces to avoid burns or clothing igni tion Fireplace will remain hot for a time...

Page 3: ...fire box Remove packing 2 Locate two screws above top corners of the fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remove protective packaging app...

Page 4: ...er sources to light fireplace THERMOSTAT CONTROL CGFP28NT These fireplaces have a thermostat sensing bulb and a control valve The thermostat controls the heat output and flame height This maintains a...

Page 5: ...Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of B...

Page 6: ...m Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directl...

Page 7: ...in reach of a 120 volt grounded electrical out let orinstallanelectricaloutletwithinreach of the blower power cord For built in in stallation an outlet accessory GA3555 is available see Accessories pa...

Page 8: ...he holes in top mounting tabs of blower with holes in wall of wrapper see Fig ure 9 Using two 8 screws provided mount blower and tighten screws firmly 5 Route terminals end of power cord through large...

Page 9: ...urn blower off before continuing Blue Wire Red Wire Green Wire Black Wire White Wire Blue Wire To Switch and Cover Assembly Figure 14 Wiring Diagram If any of the original wire as supplied with the ap...

Page 10: ...e logs and set aside noting the prop erly mounted location of each 3 Remove screws that attach log base as sembly to fireplace Carefully lift up log base assembly and remove from fire place takingcare...

Page 11: ...ly line into fire place base area while replacing log base assembly Make sure the entire flexible gas line is in fireplace base area Note If firebrick is installed make sure the back of the firebox bo...

Page 12: ...ficient with other cabi net mantels and hearth bases Thismaycreateafirehazard See Accessories page 25 for correct mantels and hearth bases Figure 21 Minimum Clearance to Wall and Ceiling 42 16 INSTALL...

Page 13: ...ocation This installation includes an approved flexible gas line if allowed by local codes after the manual shutoff valve The flexible gas line must be the last item installed on the gas piping See In...

Page 14: ...NPT tap must be upstream from fireplace see Figure 30 Check your building codes for any special requirements for locating manual shutoff valve to fireplaces Apply pipe joint sealant lightly to male th...

Page 15: ...les forming show a leak Correct all leaks at once Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 1 Disconnect fireplace and its individual manual shutoff valve from gas...

Page 16: ...e see Operating Fire place pages 17 and 18 Thermostat controlled models or pages 18 and 19 Manually controlled models Check all other internal joints for leaks 7 Turn off fireplace see To Turn Off Gas...

Page 17: ...the safety information in first column 2 Make sure manual shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any gas Then smell for gas i...

Page 18: ...the comfort level you select The ideal comfort setting will vary by householddependingupontheamountof space to be heated the output of the central heating system etc Note Selecting the HI setting will...

Page 19: ...correctpilotflamepattern Figure 45 shows an incorrect pilot flame pattern Theincorrectpilotflameisnottouch ing the thermocouple This will cause the thermocouple to cool When the thermo couple cools th...

Page 20: ...hard ware store or home center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the direc tions on the can If you d...

Page 21: ...ocouple to cool causing pilot flame to go out This problemcouldbecausedbyoneorboth of the following A Low gas pressure B DirtyorpartiallycloggedODS pilot 6 Thermocouple damaged 7 Control valve damaged...

Page 22: ...page 20 2 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed from line Hav...

Page 23: ...air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See...

Page 24: ...6514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 E Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Parts Department FBD 1349 Adams St Bo...

Page 25: ...ve ready model number of your fireplace the replacement part number REPLACEMENT PARTS CABINET MANTEL ACCESSORY WITH FIREPLACE PERIMETER BRASS TRIM GMC11F Series Walnut Finished Hardwood Veneer GMC12U...

Page 26: ...L GAS FIREPLACE CGFP28N and CGFP28NT ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY VARIABLE MANUALLY CONTROLLED MODEL CGFP28N 27 8 9 8 8 19 13 12 8 6 3 4 1 2 7 7 1 7 2 10 18 23 16 11 26 14 6 6 6 6 21...

Page 27: ...100999 05 Rear Burner Assembly 1 12 102257 08CJ Base Assembly 1 13 098271 06 Ignitor Cable 1 14 103410 01CK Firebox Bottom 1 15 098867 09 Gas Regulator 1 16 101004 04 Front Burner Injector 1 17 102445...

Page 28: ...ATURAL GAS FIREPLACE CGFP28N and CGFP28NT ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY THERMOSTAT CONTROLLED MODEL CGFP28NT 18 6 27 8 9 8 8 19 13 12 3 4 1 2 7 7 1 7 2 10 16 11 26 14 5 6 6 6 6 22 25 2...

Page 29: ...Pilot Bracket 1 10 101330 05 Front Burner Assembly 1 11 100999 02 Rear Burner Assembly 1 12 102257 08CJ Base Assembly 1 13 098271 06 Ignitor Cable 1 14 103410 01CK Firebox Bottom 1 15 098867 09 Gas R...

Page 30: ...30 103413 UNVENTED VENT FREE NATURAL GAS FIREPLACE CGFP28N and CGFP28NT ILLUSTRATED PARTS BREAKDOWN FIREPLACE CGFP28N CGFP28NT 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13...

Page 31: ...8 01CK Right Front Side 1 4 102759 01CK Left Front Side 1 5 101514 01CK Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CJ Firebox Wrapper 1 9 103412 01CK Louver Door 1 10...

Page 32: ...lated to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL O...

Reviews: