background image

18

103413

UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE

CGFP28N and CGFP28NT

Figure 43 - Pilot

Thermocouple

Ignitor Electrode

Pilot Burner

IGNITOR

LIGHTING

INSTRUCTIONS

Figure 42 - Control Knob and Ignitor
Button Location

  WARNING: You must oper-

ate this fireplace with the fire-
place screen in place. Make sure
fireplace screen is installed be-
fore running fireplace.

NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell. Orange flame will also be
present. Open window to vent
smell. Operate fireplace on HI
position to burn off odor. This
will only last a few hours.

1.

STOP! Read the safety information
in second column.

2.

Make sure manual shutoff valve is
fully open.

3.

Turn control knob clockwise 
to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation above. If you don’t smell
gas, go to the next step.

Ignitor Button

Control Knob

OPERATING
FIREPLACE

Continued

1.

Follow steps 1 through 5 under Light-
ing Instructions
, page 17.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8 under Lighting Instruc-
tions
, page 17.

Variable Manually-Controlled
Model CGFP28N

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

FOR YOUR SAFETY

READ BEFORE

LIGHTING

THERMOSTAT

CONTROL OPERATION

You can set the thermostat control knob
to any comfort level between HI and LO.
The thermostat will gradually modulate
the heat output and flame height from
higher to lower settings, or pilot, in order
to maintain the comfort level you select.
The ideal comfort setting will vary by
household depending upon the amount of
space to be heated, the output of the
central heating system, etc.

Note:

 Selecting the HI setting will cause

the burner to remain on without modu-
lating down in most cases.

MANUAL LIGHTING

PROCEDURE

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

5.

Slightly depress and turn control
knob counterclockwise 

C-clockwise

 to

the PILOT position. Press in control
knob for five (5) seconds (see Fig-
ure 42).

Note:

 If running fireplace for first

time, there will be air in gas line. You
may need to press in control knob for
30 seconds or longer. This will allow
air to bleed from the gas system.
• If control knob does not pop out

when released, contact a qualified
service person or gas supplier for
repairs.

6.

Continue pressing control knob in.
Press and release ignitor button. This
will light pilot. The pilot is attached to
the front burner. If needed, keep press-
ing ignitor button until pilot lights.

Note:

 If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure
, page 19.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

 If pilot goes out, repeat steps

3 through 7.

8.

Slightly depress and turn control
knob counterclockwise  

 to

the HIGH position. Both burners
should light. Set control knob to de-
sired heat setting.

Summary of Contents for Comfort Glow CGFP28N

Page 1: ...ualified installer service agency or the gas supplier WARNING Improperinstallation adjustment alteration service ormaintenancecancauseinjury orpropertydamage Refertothis manual for correct installatio...

Page 2: ...on logs 17 Fireplace front and screen becomes very hot when running fireplace Keep children and adults away from hot sur faces to avoid burns or clothing igni tion Fireplace will remain hot for a time...

Page 3: ...fire box Remove packing 2 Locate two screws above top corners of the fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remove protective packaging app...

Page 4: ...er sources to light fireplace THERMOSTAT CONTROL CGFP28NT These fireplaces have a thermostat sensing bulb and a control valve The thermostat controls the heat output and flame height This maintains a...

Page 5: ...Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of B...

Page 6: ...m Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directl...

Page 7: ...in reach of a 120 volt grounded electrical out let orinstallanelectricaloutletwithinreach of the blower power cord For built in in stallation an outlet accessory GA3555 is available see Accessories pa...

Page 8: ...he holes in top mounting tabs of blower with holes in wall of wrapper see Fig ure 9 Using two 8 screws provided mount blower and tighten screws firmly 5 Route terminals end of power cord through large...

Page 9: ...urn blower off before continuing Blue Wire Red Wire Green Wire Black Wire White Wire Blue Wire To Switch and Cover Assembly Figure 14 Wiring Diagram If any of the original wire as supplied with the ap...

Page 10: ...e logs and set aside noting the prop erly mounted location of each 3 Remove screws that attach log base as sembly to fireplace Carefully lift up log base assembly and remove from fire place takingcare...

Page 11: ...ly line into fire place base area while replacing log base assembly Make sure the entire flexible gas line is in fireplace base area Note If firebrick is installed make sure the back of the firebox bo...

Page 12: ...ficient with other cabi net mantels and hearth bases Thismaycreateafirehazard See Accessories page 25 for correct mantels and hearth bases Figure 21 Minimum Clearance to Wall and Ceiling 42 16 INSTALL...

Page 13: ...ocation This installation includes an approved flexible gas line if allowed by local codes after the manual shutoff valve The flexible gas line must be the last item installed on the gas piping See In...

Page 14: ...NPT tap must be upstream from fireplace see Figure 30 Check your building codes for any special requirements for locating manual shutoff valve to fireplaces Apply pipe joint sealant lightly to male th...

Page 15: ...les forming show a leak Correct all leaks at once Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 1 Disconnect fireplace and its individual manual shutoff valve from gas...

Page 16: ...e see Operating Fire place pages 17 and 18 Thermostat controlled models or pages 18 and 19 Manually controlled models Check all other internal joints for leaks 7 Turn off fireplace see To Turn Off Gas...

Page 17: ...the safety information in first column 2 Make sure manual shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any gas Then smell for gas i...

Page 18: ...the comfort level you select The ideal comfort setting will vary by householddependingupontheamountof space to be heated the output of the central heating system etc Note Selecting the HI setting will...

Page 19: ...correctpilotflamepattern Figure 45 shows an incorrect pilot flame pattern Theincorrectpilotflameisnottouch ing the thermocouple This will cause the thermocouple to cool When the thermo couple cools th...

Page 20: ...hard ware store or home center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the direc tions on the can If you d...

Page 21: ...ocouple to cool causing pilot flame to go out This problemcouldbecausedbyoneorboth of the following A Low gas pressure B DirtyorpartiallycloggedODS pilot 6 Thermocouple damaged 7 Control valve damaged...

Page 22: ...page 20 2 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed from line Hav...

Page 23: ...air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See...

Page 24: ...6514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 E Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Parts Department FBD 1349 Adams St Bo...

Page 25: ...ve ready model number of your fireplace the replacement part number REPLACEMENT PARTS CABINET MANTEL ACCESSORY WITH FIREPLACE PERIMETER BRASS TRIM GMC11F Series Walnut Finished Hardwood Veneer GMC12U...

Page 26: ...L GAS FIREPLACE CGFP28N and CGFP28NT ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY VARIABLE MANUALLY CONTROLLED MODEL CGFP28N 27 8 9 8 8 19 13 12 8 6 3 4 1 2 7 7 1 7 2 10 18 23 16 11 26 14 6 6 6 6 21...

Page 27: ...100999 05 Rear Burner Assembly 1 12 102257 08CJ Base Assembly 1 13 098271 06 Ignitor Cable 1 14 103410 01CK Firebox Bottom 1 15 098867 09 Gas Regulator 1 16 101004 04 Front Burner Injector 1 17 102445...

Page 28: ...ATURAL GAS FIREPLACE CGFP28N and CGFP28NT ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY THERMOSTAT CONTROLLED MODEL CGFP28NT 18 6 27 8 9 8 8 19 13 12 3 4 1 2 7 7 1 7 2 10 16 11 26 14 5 6 6 6 6 22 25 2...

Page 29: ...Pilot Bracket 1 10 101330 05 Front Burner Assembly 1 11 100999 02 Rear Burner Assembly 1 12 102257 08CJ Base Assembly 1 13 098271 06 Ignitor Cable 1 14 103410 01CK Firebox Bottom 1 15 098867 09 Gas R...

Page 30: ...30 103413 UNVENTED VENT FREE NATURAL GAS FIREPLACE CGFP28N and CGFP28NT ILLUSTRATED PARTS BREAKDOWN FIREPLACE CGFP28N CGFP28NT 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13...

Page 31: ...8 01CK Right Front Side 1 4 102759 01CK Left Front Side 1 5 101514 01CK Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CJ Firebox Wrapper 1 9 103412 01CK Louver Door 1 10...

Page 32: ...lated to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL O...