background image

18

107553

UNVENTED NATURAL GAS LOG HEATER

For more information, visit www.desatech.com

CLEANING AND
MAINTENANCE

 WARNING: Turn off heater

and let cool before cleaning.

 CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.

LOGS

• If you remove logs for cleaning, refer to

Installing Logs, pages 13 through 15, to
properly replace logs.

• Replace log(s) if broken or chipped

(dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
come blocked by debris or rust, with no
flame present. If so, turn off heater and let
cool. Either remove blockage or replace
burner. Blocked burner flame holes will
create soot.

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni-
cal Service Department at 1-800-DESA LOG
(1-800-337-2564).

You can also visit DESA International’s
technical service web site at

www.desatech.com.

For information or questions concerning
hand-held remote or receiver, contact Track-
ing Technology at 1-800-301-0440 or

www.trackingtech.com

.

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

When Gas Quality Is Bad

• pilot will not stay lit

• burners will produce flames and soot

• heater will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
natural gas supplier.

SERVICE HINTS

CLEANING BURNER
INJECTOR HOLDER AND
PILOT AIR INLET HOLE

The primary air inlet holes allow the proper
amount of air to mix with the gas. This
provides a clean burning flame. Keep these
holes clear of dust, dirt, lint, and pet hair.
Clean these air inlet holes prior to each
heating season. Blocked air holes will cre-
ate soot. We recommend that you clean the
unit every three months during operation
and have heater inspected yearly by a quali-
fied service person.

We also recommend that you keep the burner
tube and pilot assembly clean and free of
dust and dirt. To clean these parts we recom-
mend using compressed air no greater than
30 PSI. Your local computer store, hard-
ware store, or home center may carry com-
pressed air in a can. You can use a vacuum
cleaner in the blow position. If using com-
pressed air in a can, please follow the direc-
tions on the can. If you don't follow direc-
tions on the can,  you could damage the pilot
assembly.

1.

Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.

2.

Inspect burner, pilot, and primary air
inlet holes on injector holder for dust
and dirt (see Figure 39).

3.

Blow air through the ports/slots and
holes in the burner.

Figure 39 - Injector Holder On Outlet
Burner Tube

4.

Check the injector holder located at the
end of the burner tube again. Remove
any large particles of dust, dirt, lint, or
pet hair with a soft cloth or vacuum
cleaner nozzle.

5.

Blow air into the primary air holes on
the injector holder.

6.

In case any large clumps of dust have
now been pushed into the burner repeat
steps 3 and 4.

Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 40). With the unit off, lightly
blow air through the air inlet hole. You may
blow through a drinking straw if compressed
air is not available.

Burner
Tube

Injector Holder

Primary Air
Inlet Holes

Figure 40 - Pilot Inlet Air Hole

Burner
Tube

Pilot
Assembly

Pilot Air
Inlet
Hole

Ports/Slots

Summary of Contents for Comfort Glow CCL3924NR

Page 1: ...NRA CCL3924NR CCL3930NR 24 and 30 Remote Ready P I L O T O F F O N LO REMOTE OFF HI Also Design Certified As Vented Decorative Appliances When Not Used With Hand Held Thermostat Remote OWNER S OPERATI...

Page 2: ...ke turn offheaterandcallaqualifiedserviceper son Note Duringinitialoperation slight smokingmayoccurduetologcuringand heater burning manufacturing residues 7 To prevent the creation of soot follow the...

Page 3: ...ly by grate 2 Remove all protective packaging ap plied to logs and heater for shipment 3 Check all items for any shipping dam age If damaged promptly inform dealer where you bought heater UNPACKING PR...

Page 4: ...construction is de fined as construction where a walls and ceilings exposed to the outside atmosphere have a con tinuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or le...

Page 5: ..._____________Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the a...

Page 6: ...ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thesespaces include a...

Page 7: ...tateorlocalcodesmay onlyallowoperationofthisappli ance in a vented configuration Check your state or local codes WARNING Make sure the se lector switch is in the OFF posi tion before installing heater...

Page 8: ...27 Less than 8 Noncombustible material must be extended to at least 8 See Between 8 and 12 above If you cannot extend material you must operate heater with flue damper open Figure 5 Heat Resistant Mat...

Page 9: ...tallation does notmeettheminimumclearances shown you must do one of the following operate the logs only with the flue damper open raise the mantel to an accept able height remove the mantel 14 Min Com...

Page 10: ...e Figure 12 page 11 If installing in a brick bottom fire place mark screw locations in mortar joint of bricks 5 Remove heater base from fireplace 6 Drill holes at marked locations using 3 16 masonry d...

Page 11: ...to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Usepipejointseal ant that is resistant to liquid pe troleum...

Page 12: ...Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 14 2 Pressurizesupplypipingsystembyeither usingcompressedairoropeningmaingas valve located on or near...

Page 13: ...ont Log 3 Recess Post Post Burner Cutout Continued CAUTION After installation andperiodicallythereafter check to ensure that no flame comes in contact with any log With the heater set to HIGH check to...

Page 14: ...g rests firmly between the grate fingers and the grate base see Figure 26 2 Place the base of the middle log 2 in the U shaped slots of the grate base The cutout on the right of the middle log shouldf...

Page 15: ...he OFF position 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in formation columns 1 and 2 If you don t smell gas...

Page 16: ...s lit You may shut off the burners and keep the pilot lit by doing one of the following 1 Turn control knob clockwise to the PILOT position 2 UseremotecontrolmanualOFFbutton 3 SetselectorswitchintheOF...

Page 17: ...ockage or replace burner Blocked burner flame holes will create soot CGHRCTA Series Operation 2b Press the AUTO ON OFF button on the hand held remote control see Figure 36 The lights to the left of th...

Page 18: ...G BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of dust dirt...

Page 19: ...7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut...

Page 20: ...nti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Obse...

Page 21: ...er produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odo...

Page 22: ...HEATER For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN CGD3924NRA 7 16 16 17 25 16 3 2 1 4 11 21 10 9 12 15 8 19 18 20 6 14 5 13 27 26 26 22 23 24 O F F P I L O T O N H I L O...

Page 23: ...102772 01 Burner 1 13 099387 12 Pilot Tube Valve to Regulator 1 14 103781 01 Gas Control Valve 1 15 103345 01 Lower Bracket 1 16 M11084 38 Screw 8 x 38 7 17 102775 06CK Painted Base Assembly 1 18 098...

Page 24: ...or more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN CCL3924NR CCL3930NR 30 18 18 19 27 18 13 23 12 11 14 4 5 1 2 17 10 21 20 22 6 7 3 9 16 8 15 29 28 28 25 26 O F F P I L O T O N H...

Page 25: ...8 M11084 38 M11084 38 Screw 8 x 38 7 19 102775 06CK 102775 06CK Painted Base Assembly 1 20 098271 07 098271 07 Ignitor Cable 1 21 102445 01 102445 01 Piezo Ignitor 1 22 103587 02CK 103587 02CK Plate S...

Page 26: ...riginal replacement parts and accessories Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valpar...

Page 27: ...ur near est Parts Central see page 26 or call DESA International s Sales Department at 1 800 972 7879 for referral information You can also write to the address listed on the back page of this manual...

Page 28: ...to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES AN...

Reviews: