15
103569
OWNER’S MANUAL
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-800-323-5190.
SPECIFICATIONS
RP30D
CGP20(L)
Btu (Variable)
15,000/30,000
10,000/20,000
Type Gas
Propane/LP Only
Propane/LP Only
Ignition
Piezo
Piezo
Pressure Regulator Setting
8" W.C.
8" W.C.
Inlet Gas Pressure (inches of water)
Maximum
14"
14"
Minimum
11"
11"
Dimensions, Inches (H x W x D)
Heater
23.5 x 25.9 x 8.0
23.5 x 18.5 x 8.0
Carton
26 x 27.75 x 9.63
26 x 20.5 x 9.63
Weight (pounds)
Heater
30
22
Shipping
35
27
When gas pressure is too low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.
SERVICE HINTS
CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting
and bedding material, sawdust,
cobwebs, etc.
ODS/PILOT AND BURNER
• Use a vacuum cleaner, pressurized air, or
small, soft bristled brush to clean.
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air
to clean.
Exterior
• Use a soft cloth dampened with a mild
soap and water mixture. Wipe the cabi-
net to remove dust.