background image

6

103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

 CAUTION: If you install the

heater in a home garage
• heater pilot and burner must

be at least 18 inches above
floor

• locate heater where moving

vehicle will not hit it

For convenience and efficiency, install heater

• where there is easy access for operation,

inspection, and service

• where strong wind gusts from an open

door or garage door can not blow directly
into heater.

An optional fan kit is available from your
dealer. See Accessories, page 17. If plan-
ning to use fan, locate heater near an electri-
cal outlet.

36"

*

FLOOR

CEILING

Minimum

Minimum To Floor

6"

Minimum
From
Sides Of
Heater

Left
Side

Right
Side

*16

3

/

4

"

- RP30D

*3"

- CGP20(L)

Figure 4 - Mounting Clearances As Viewed From Front of Heater

INSTALLING TO
WALL

NOTICE: A qualified service per-
son must install heater. Follow
all local codes.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply
is not propane/LP, do not install heater. Call
dealer where you bought heater for proper
type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have
the items listed below.

• external regulator (supplied by installer,

see page 8)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• manual shutoff valve *

• ground joint union

• test gauge connection * (see Figure 13,

page 9)

• sediment trap

• tee joint

• pipe wrench

*  An A.G.A. design certified manual shutoff

valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional A.G.A. design certi-
fied manual shutoff valve from your
dealer. See Accessories, page 17.

LOCATING HEATER

This heater is designed to be mounted on a
wall.

Continued

 WARNING: Maintain the mini-

mum clearances shown in Figure
4. If you can, provide greater clear-
ances from floor, ceiling, and join-
ing wall.

You can locate model CGP20 and CGP20L
on floor, away from a wall. An optional
floor mounting stand is needed. Purchase
the floor mounting stand from your dealer.
See Accessories, page 17.

 WARNING: Never install the

heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the heater

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

 CAUTION: This heater cre-

ates warm air currents. These cur-
rents move heat to wall surfaces
next to heater. Installing heater
next to vinyl or cloth wall cover-
ings or operating heater where
impurities in the air (such as to-
bacco smoke) exist, may discolor
walls.

IMPORTANT:

 Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation, 
pages 3 through 5.

Summary of Contents for CGP20

Page 1: ...apors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building...

Page 2: ...g WARNING ICON G 001 WARNINGS DANGER Carbon monoxide poisoning may lead to death WARNING Anychangetothis heater or its controls can be dan gerous 2 Do not place propane LP supply tank s inside any str...

Page 3: ...space Adjoining rooms are communicating only iftherearedoorlesspassagewaysorventila tion grills between them WARNING This heater shall not be installed in a confined space unless provisions are pro vi...

Page 4: ...gas heater ________ Btu Hr Gas fireplace logs ________ Btu Hr Other gas appliances ____ Btu Hr Total ____ Btu Hr Example Gas water heater 40 000 Btu Hr Vent free heater 20 000 Btu Hr Total 60 000 Btu...

Page 5: ...Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items...

Page 6: ...onnection see Figure 13 page 9 sediment trap tee joint pipe wrench AnA G A design certified manual shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Pur chase the op...

Page 7: ...nchor method For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at marked locations using 5 16 drill bit For solid walls concrete...

Page 8: ...st gauge hook up NPT tap must be upstream from heater see Figure 13 page 9 Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe...

Page 9: ...em Pressures in excess of 1 2 PSIG will damage heater regulator 2 Cap off open end of gas pipe where manual shutoff valve was connected 3 Pressurize supply piping system by ei ther using compressed ai...

Page 10: ...s appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions ex actly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to...

Page 11: ...flame pattern and burner flame pattern often PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pat tern Figure 19 shows an incorrect pilot flame pattern The incorrect pilot flame is not touchi...

Page 12: ...tionlooseatcon trol valve 5 Pilotflamenottouchingthermocouple which allows thermocouple to cool causing pilot flame to go out This problemcouldbecausedbyoneorboth of the following A Low gas pressure B...

Page 13: ...n heater blocked 4 Dirty or partially clogged burner ori fice Continued REMEDY 1 Contactlocalpropane LPgascompany 2 Clean burner see Cleaning and Main tenance page 15 or replace burner orifice 1 Clean...

Page 14: ...rtially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Notenoughc...

Page 15: ...propane LP gas supply may be low When gas quality is bad pilot will not stay lit burner will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is ba...

Page 16: ...placementpartsandaccessories Whencall ing a Parts Central ask for the Parts Depart ment Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 1 800 397 7553 203 248 7553 Parts Department Portable He...

Page 17: ...AL SHUTOFFVALVE GA5010 For all models Manual shutoff valve with 1 8 NPT tap FLOOR MOUNTING STAND 20 000 Btu Hr Models CGP20L GA4500L Ivory CGP20 GA4500 Earthtone For locating heater on the floor away...

Page 18: ...103569 VENT FREE PROPANE LP GAS HEATER BLUE FLAME CGP20 CGP20L AND RP30D 1 2 4 5 6 7 8 8 9 10 11 12 15 17 19 21 22 23 24 20 27 26 18 14 16 25 3 13 ODS PILOT 10 1 10 2 ILLUSTRATED PARTS BREAKDOWN RP30...

Page 19: ...1 098514 01 Thermocouple 1 10 2 098594 01 Ignitor Electrode 1 11 103447 01 Burner 1 12 099387 05 3 16 Pilot Tubing 1 13 103845 03 Injector 1 14 099066 01 Mounting Bracket 1 15 099415 06 Pressure Regul...

Page 20: ...VENT FREE PROPANE LP GAS HEATER BLUE FLAME CGP20 CGP20L AND RP30D ODS PILOT 12 1 12 2 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 17 19 27 21 23 24 25 26 22 29 28 20 16 18 15 ILLUSTRATED PARTS BREAKDOWN CGP2...

Page 21: ...M5 2 12 099059 04 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 103446 01 Burner 1 14 099387 05 3 16 Pilot Tubing 1 15 103845 01 Injector 1 16 099066 01 Mou...

Page 22: ...____________________________________________ _______________________________________________________________________________________________ ___________________________________________________________...

Page 23: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 24: ...is warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance o...

Reviews: