Continued

We  recommend  that  you  install  a  sediment 
trap  in  supply  line  as  shown  in  Figure  8. 
Locate sediment trap where it is within reach 
for cleaning. Install in piping system between 
fuel  supply  and  heater.  Locate  sediment 
trap  where  trapped  matter  is  not  likely  to 

freeze. A  sediment  trap  traps  moisture  and 

contaminants.  This  keeps  them  from  going 

into fireplace controls. If sediment trap is not 
installed or is installed wrong, fireplace may 

not run properly.

* Purchase the optional CSA design-certified 
equipment shutoff valve from your dealer.

Figure 8 - Gas Connection

CSA Design-

Certified Equipment 

Shutoff Valve With 

1/8" NPT Tap*

3" Minimum

Approved 
Flexible Gas 
Line

Pipe Nipple   Cap   Tee Joint

Propane/LP

 

From External 

Regulator (11" 
W.C.** to 14" 

W.C. Pressure)

NATURAL

 

From Gas 

Meter (5" 
W.C.** to 10.5" 

W.C. Pressure)

Sediment Trap

Figure 9 - Attaching Flexible Gas Line to 

Equipment Shutoff Valve

Flexible Gas Line 
from Fireplace Gas 
Regulator Provided 
With Fireplace

To Gas 
Regulator

Equipment 

Shutoff Valve

PROPANE/LP

 

To External 
Regulator

NATURAL

To Gas Supply

CONNECTING FIREPLACE TO GAS 
SUPPLY

Installation Items Needed

•  Phillips screwdriver
•  sealant (resistant to propane/LP gas, not 

provided)

NOTICE:  Most  building  codes 

do  not  permit  concealed  gas 

connections. A flexible gas line 

is provided to allow accessibility 

from the fireplace. The flexible 

gas supply line connection to the 

equipment shutoff valve should 

be accessible.

1.  Route  flexible  gas  line,  included,  from 

fireplace  control  to  equipment  shutoff 

valve through side or rear access holes 

in outer casing (see Figure 1, page 5).

2.  Apply  pipe  joint  sealant  lightly  to  male 

threads  of  gas  connector  attached  to 

flexible gas line/equipment shutoff valve 

(see Figure 9).

 CAUTION: Avoid damage to 

regulator.  Hold  gas  regulator 

with wrench when connecting it 

to gas piping and/or fittings.

3.  Check all gas connections for leaks. See 

Checking Gas Connections, 

page 14.

4.  Feed flexible gas line into fireplace base 

area  while  replacing  branch  support. 

Make  sure  entire  flexible  gas  line  is  in 
fireplace base area.

Summary of Contents for CFFP18NT

Page 1: ...y appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your...

Page 2: ...use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING...

Page 3: ...tered burner patterns can cause sooting Due to high temperatures the appliance should be located out oftrafficandawayfromfurniture and draperies SAFETY Continued Do not place clothing or other flammab...

Page 4: ...ea of fireplace 7 This fireplace is designed to be smokeless If logs ever appear to smoke turn off fire place and call a qualified service person Note During initial operation slight smok ing could oc...

Page 5: ...ton Log is wrapped and inside fireplace Do not remove at this time 2 Remove all protective packaging applied to fireplace for shipment 3 Make sure fireplace includes one hard ware packet 4 Check firep...

Page 6: ...hillips screwdriver 5 16 hex wrench slotted screwdriver scissors 1 Remove two screws that hold fireplace screen in place for shipping These screws are located near top of screen Discard screws Lift fi...

Page 7: ...e and provide adequate ventilation The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you mus...

Page 8: ...page 9 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts 30 000 10 000 40 000 DETERMINING FRESH AIR FLOW FOR FI...

Page 9: ...for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo stat controlled power vent Heated air entering the attic wi...

Page 10: ...and service in coldest part of room CAUTION This fireplace cre ates warm air currents These currents move heat to wall sur faces next to fireplace Installing fireplacenexttovinylorclothwall coverings...

Page 11: ...Combustible to Wall Minimum 16 from Side Wall Example NOTICE Surface temperatures ofadjacentwallsandmantelsbe comehotduringoperation Walls and mantels above the firebox may become hot to the touch If...

Page 12: ...e gas line to fireplace gas regulator See Connecting to Gas Supply 5 Check all gas connections for leaks See Checking Gas Connections page 14 CONNECTING TO GAS SUPPLY WARNING This appliance requires a...

Page 13: ...Gas Line from Fireplace Gas Regulator Provided With Fireplace To Gas Regulator Equipment Shutoff Valve Propane LP To External Regulator NaturAL To Gas Supply CONNECTING Fireplace to Gas Supply Install...

Page 14: ...e LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all j...

Page 15: ...lve to gas regulator see Figure 11 page 14 or Figure 12 Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light fireplace see Operation pa...

Page 16: ...he screen in place Make sure fireplace screen is installed before run ning fireplace Figure 14 Control Knob In the OFF Position Piezo Ignitor Control Knob NOTICE During initial opera tion of new firep...

Page 17: ...ghting Instructions page 16 2 With control knob pressed in strike match Hold match to pilot until pilot lights 3 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds rele...

Page 18: ...pect burner pilot and primary air inlet holes on injector holder for dust and dirt see Figure 20 3 Blow air through the ports slots and holes in the burner 4 Check injector holder located at the end o...

Page 19: ...ctrode not con nected to ignitor cable 2 Ignitor cable pinched or wet 3 Broken ignitor cable 4 Bad ignitor 5 Ignitor electrode posi tioned wrong 6 Ignitor electrode broken REMEDY 1 Reconnect ignitor c...

Page 20: ...ow gas pressure B Dirty or partially clogged ODS pilot 5 Thermocouple connection loose at control valve 6 Thermocouple damaged 7 Control valve damaged 1 Inlet gas pressure is too low 2 Burner orifice...

Page 21: ...heated vapors from furniture polish wax carpet cleaners etc may turn into white powder residue 1 Not enough combustion ventilation air REMEDY 1 Contact local natural or propane LP gas company 2 Clean...

Page 22: ...2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning...

Page 23: ...on tact DESA Heating LLC at 1 866 672 6040 When calling please have your model and serial numbers of your heater ready You can also visit DESA Heating LLC s web site at www desatech com Replacement Pa...

Page 24: ...www desatech com 123779 01C 24 Parts Firebox Models CFFP18NT AND CFFP18PT Not shown to scale 1 2 4 3 5 6 7 9 10 11 10 8 16 17 12 13 14 15...

Page 25: ...1 124043 01 Top Trim Panel 1 2 123698 01 21 Fireplace Wrapper 1 3 123701 01 Firebox Hood 1 4 123700 01 Heat Deflector 1 5 118941 04 Top Liner 1 6 118941 02 Left Side Liner 1 7 118941 01 Rear Liner 1 8...

Page 26: ...www desatech com 123779 01C 26 Parts Burner Models CFFP18NT AND CFFP18PT 1 4 5 6 8 16 9 10 11 15 12 7 2 3 17 13 14...

Page 27: ...ur fireplace When ordering parts follow the instructions listed under Replacement Parts on page 23 of this manual KEY NO PART NO DESCRIPTION QTY 1 119310 01 Burner 1 2 112881 05 Pilot Shield 1 3 12063...

Page 28: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Reviews: