Auto (Thermostatic) Mode
1. Press the POWER and LOCK buttons
together to turn on the hand-held remote
control.
2. Press AUTO button to select this mode.
3. Set the desired room temperature by
pressing the TEMP + or - buttons.
4. Press the POWER and LOCK buttons
together to turn off the fireplace
Note: Do not leave the hand-held remote in
the AUTO mode close to the fireplace. The
radiant heat from the fireplace will turn off the
fireplace. Ideally, place the hand-held remote
in the center of the room facing towards the
fireplace.
Note: Do not hold the hand-held remote for
a long time. Body temperature will affect its
operation in the AUTO mode.
Safety Features
When away from home for an extended period
of time or as a child safety feature to prevent
accidental ignition of the fireplace, the receiver
ON/OFF/REMOTE switch should be in the
OFF position.
Auto Shutoff Feature
1. If the average room temperature reaches
a range of 82° F (28° C) to 92° F (33° C),
the hand-held remote control will perform
a safety override and shut the fireplace off.
This feature is not available in the MANU
mode.
2. The receiver continuously receives sig-
nals from the hand-held remote to control
the room temperature. If the hand-held
remote is misplaced, obstructed or for any
reason cannot transmit to the receiver, the
receiver will shut off the fireplace. This will
occur in 8 or more minutes depending
upon location of remote transmitter and
strength of batteries.
Key Pad Lock Feature
This feature allows the user to lock/unlock the
keypad on the hand-held remote in the MANU
or AUTO mode to prevent inadvertent op-
eration (i.e. children operating the hand-held
remote control, etc.). The keypad is locked in
either on or off. Press the POWER and LOCK
buttons together to turn the unit on or off.
OPTIONAL GWMT1 WALL
MOUNTED THERMOSTAT
Set the temperature adjustment on wall ther
-
mostat to the desired setting. The thermostat
has been electronically calibrated at the fac-
tory and requires no adjustment or leveling.
Upon installation, the thermostat must be
allowed to stabilize at room temperature for
a minimum of 30 minutes for proper opera-
tion. See installation instructions on pages
16 and 17.
OPTIONAL GWMS2 WALL
MOUNTED SWITCH
This wall switch works just like the conven
-
tional light switch. Flip switch up for on and
down for off.
Note: Make sure that this switch is not in a posi-
tion to be mistaken for a light switch. This may
result in the fireplace being inadvertently turned
on without the proper precautions being taken.
See installation instructions on page 17.
opERaTioN
Continued
REmoTE-REaDy moDEls