background image

3

105453

OWNER’S MANUAL

PRODUCT
IDENTIFICATION

Install and use fireplace with care. Follow all
local codes. In the absence to local codes,
use the current National Fuel Gas Code
ANS Z223.1
, also known as NFPA 54* (USA)
or the current CAN/CGA-B149[.1 or .2]
Installation Codes 
(Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

LOCAL CODES

PRODUCT
FEATURES

OPERATION

This direct-vent fireplace is clean burning
and vents easily through outside walls or
vertically using outside air for combustion.
Heat is generated by both realistic flames
and glowing embers. When used without
the blower accessory, the fireplace requires
no electricity making it ideal for emergency
backup heat.

PIEZO IGNITOR

This fireplace has a piezo ignitor. This sys-
tem requires no matches, batteries, or other
sources to light fireplace.

Figure 1 - Vanguard Direct-Vent Fireplace BDV Series

Glass Door
Assembly

Blower Adjustment
(Optional Installation)

Piezo Ignitor

Valve

Burner

Pilot Assembly

Log Set

Grate Assembly

Lava Rock

Glowing Embers

Top Louver
Panel

Lower Louver
Panel

         Vent Opening

Nailing
Flange

Stand-off

GLOSSARY OF
TERMS

Chase

 - A box-like enclosure to protect

venting from the elements when the venting
run is on the outside of a structure.

Mastic 

- A pliable sealent for use around

the vent terminal.

Snorkel Termination

 - A box that raises

the horizontal termination above ground
level clearances.

Vent Terminal

 - Mounted on an outside

wall or roof to separate the inlet and outlet of
the vent system and protect it from weather.

Vinyl Siding Standoff

 - A metal box that

separates the vent cap from vinyl siding.

Wall Thimble/Firestop

 - A metal plate

used to secure the vent pipe when it passes
through a wall or ceiling.

Summary of Contents for BDV34N

Page 1: ...fer to this manual for correct in stallation and operational procedures Forassistance or additional information consultaqualifiedinstaller service agency or the gas supplier This appliance may be inst...

Page 2: ...rly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide Poisoning Early signsofcarbo...

Page 3: ...OR This fireplace has a piezo ignitor This sys tem requires no matches batteries or other sources to light fireplace Figure 1 Vanguard Direct Vent Fireplace BDV Series Glass Door Assembly Blower Adjus...

Page 4: ...3 20 34 3 4 5 8 for drywall facing Must maintain a minimum 1 clearance to combustibles 34 1 2 34 3 4 20 Vertical Termination 19 Horizontal Termination CLEARANCES Minimum clearances to combustibles for...

Page 5: ...pe cifically approved for this fireplace Minimum clearance between vent pipes and combustible materials is 1 25 mm except where stated otherwise Combustible material may be flush with the top front of...

Page 6: ...de walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum of 24 inche...

Page 7: ...proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of vertical rise desired The horizon tal...

Page 8: ...appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations These lugs will slide straight i...

Page 9: ...f 1 to combustibles is maintained At tach the vent cap with four wood screws supplied see Figure 13 Note Re place the wood screws with appropri ate fasteners for stucco brick concrete or other types o...

Page 10: ...for use with corner installation UP Horizontal Venting See information in Figures 17 and 18 for Vertical V and Horizontal H maxi mums and minimums The same amounts apply for flexible venting BVK Vent...

Page 11: ...max 8 min 8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 19 Horizontal Termi...

Page 12: ...as specified in the second warning state ment on page 7 Be sure all pipe and elbow connections are fully twist locked see Figure 11 page 9 3 Cut a hole in the roof using the locating hole as a center...

Page 13: ...Cut hole 1 8 larger than support box when projected onto roofline 2 minimum below finished ceiling Cathedral ceiling support box Level 3 Lower the support box through the hole in the roof until the b...

Page 14: ...No Horizontal Run VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 27 V...

Page 15: ...of Flashing RTV Silicone VerticalTermination and26screws D1000 7 x 12 Galvanized Coaxial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x 48 Galvanized Coaxial Pipe 6 pcs D1030 7 Adjust...

Page 16: ...un system scirculatingblowerwhile using heater This will help circu late the heat throughout the house In the event of a power outage you can use this heater as your primary heat source NOTICE A quali...

Page 17: ...the right side see Figure 33 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system insta...

Page 18: ...con nector if allowed by local codes not provided AnA G A design certifiedmanualshutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Pur chase the A G A design certifie...

Page 19: ...provided by installer from manual shutoff valve to fireplace Route flexible gas supply line through one of the access holes on side of fireplace 3 Attach flexible gas line from gas sup ply to control...

Page 20: ...gure 39 for natu ral Apply commercial leak test solu tion to all gas joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operating Fire place pages 24 and 25 Check all o...

Page 21: ...witch bracket Lean bracket forward so you are able to ac cess the back of the remote receiver 3 Locate the battery clip mounted on the back of the receiver Slide a 9 volt bat tery not included through...

Page 22: ...ebox see Figure 46 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right brick panel using th...

Page 23: ...lace model numbers WARNING Failure to position thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal inju...

Page 24: ...not require ac cessing for lighting 8 Turn knob on gas control counter clockwise to PILOT 9 Push in control knob all the way and hold Immediately light the pilot by repeatedly depressing the piezo spa...

Page 25: ...h is in the ON position In the OFF position the blower will not operate Note for DA3610T Only Your fireplace and blower will not turn on and off at the same time The fireplace may run for sev eral min...

Page 26: ...ol before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of fireplace clean Inspect these areas of fire place before each use Have fire place inspected yearly by a...

Page 27: ...loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut hold...

Page 28: ...t warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane gas company 3 Clean burner see Cleaning and Maintenance page 26 or replace burner orifice...

Page 29: ...nt above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when cont...

Page 30: ...n servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Red Variable Fan Switch Fan Switch N O Black Black Green White On 110 115 V A C Blo...

Page 31: ...anifold Pressure 3 5 w c 10 0 w c Minimum Inlet Supply Pressure 4 5 w c 11 0 w c Dimension Inches mm HxWxD Fireplace 33 x 34 x 18 1 2 33 x 34 x 18 1 2 838 x 940 x 470mm 838 x 940 x 470mm Carton 37 x 4...

Page 32: ...rim accessories Dimensions WxHxD 56 3 4 x48 3 4 x22 7 8 HARDWOOD HEARTH BASE G3000F Series Walnut Finished G3001U Series Unfinished G3006F Series Oak Finished with Medium Stain G3007U Series Unfinishe...

Page 33: ...lack louvers by screwing into place DECORATIVE 2 PIECE BRASS ACCENT TRIM D7034 Not Shown Thesestripshaveamagneticbackingwhich makes installation and removal quick and easy They are designed to go at t...

Page 34: ...L PROPANE ILLUSTRATED PARTS BREAKDOWN BDV34N A 1 2 3 4 6 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 3 31 2 31 4 31 1 32 33 32 34 46 5 5 5 35...

Page 35: ...Natural 1 18 104497 01 SIT Pilot Natural 1 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignito...

Page 36: ...L PROPANE ILLUSTRATED PARTS BREAKDOWN BDV34P A 1 2 3 4 6 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 3 31 2 31 4 31 1 32 33 32 34 46 5 5 5 35...

Page 37: ...Natural 1 18 104497 02 SIT Pilot Natural 1 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignito...

Page 38: ...ing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED...

Reviews: