background image

12

103112

VENT FREE PROPANE/LP GAS HEATER

BLUE FLAME 6000 BTU/HR

TROUBLESHOOTING

Note: All troubleshooting items are listed
in order of operation.

 WARNING: Turn off heater

and let cool before servicing. Only
a qualified service person should
service and repair heater.

 CAUTION: Never use a wire,

needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.

POSSIBLE CAUSE

1. Ignitor electrode positioned wrong
2. Ignitor electrode broken
3. Ignitor electrode not connected to igni-

tor cable

4. Ignitor cable pinched or wet

5. Piezo ignitor nut is loose

6. Broken ignitor cable
7. Bad piezo ignitor

1. Gas supply turned off or manual shutoff

valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in PI-

LOT position

4. Air in gas lines when installed

5. Depleted gas supply
6. ODS/pilot is clogged

7. Gas regulator setting is not correct

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Manual shutoff valve not fully open
4. Thermocouple connection loose at con-

trol valve

5. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A)

Low gas pressure

B)

Dirty or partially clogged ODS/

pilot

6. Thermocouple damaged
7. Control valve damaged

REMEDY

1. Replace ignitor
2. Replace ignitor
3. Reconnect ignitor cable

4. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

5. Tighten nut holding piezo ignitor to

heater cabinet. Nut is located inside
heater cabinet at top

6. Replace ignitor cable
7. Replace piezo ignitor

1. Turn on gas supply or open manual

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob.

Repeat igniting operation until air is re-
moved

5. Contact local propane/LP gas company
6. Clean ODS/pilot (see Cleaning and

Maintenance, page 11) or replace ODS/
pilot assembly

7. Replace gas regulator

1. Press in control knob fully
2. After ODS/pilot lights, keep control

knob pressed in 30 seconds

3. Fully open manual shut-off valve
4. Hand tighten until snug, then tighten 1/4

turn more

5. A) Contact local propane/LP gas com-

pany

B) Clean ODS/pilot (see Cleaning and
Maintenance
, page 11) or replace ODS/
pilot assembly

6. Replace thermocouple
7. Replace control valve

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at ODS/pilot

When ignitor button is pressed, there is
spark at ODS/pilot but no ignition

ODS/pilot lights but flame goes out when
control knob is released

Continued

Summary of Contents for 6000 BTU/HR

Page 1: ...r call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from t...

Page 2: ...hbor s phone Follow the gas supplier s instructions if you cannot reach your gas supplier call the fire department 4 Never install the heater in a recreational vehicle where curtains furniture clothin...

Page 3: ...ew materials increased insulation and new construction methods help reduce heat loss in homes Home own ers weather strip and caulk around windows and doors to keep the cold air out and the warm air in...

Page 4: ...plates and floors between wall ceil ing joints between wall panels at penetrations for plumbing electrical and gas lines and at other openings If your home meets all of the three criteria above you m...

Page 5: ...ze of ventilation grills or ducts WARNING Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Fig...

Page 6: ...TING HEATER This heater is designed to be mounted on a wall WARNING Maintainthemini mumclearancesshowninFigure 4 Ifyoucan providegreaterclear ances from floor ceiling and joining wall Forconveniencean...

Page 7: ...ace Thin or Thick Wall thick wall shown Solid Wall Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large openings of slots over screwheads Sli...

Page 8: ...o gas pip ing and or fittings Figure 13 Gas Connection An A G A design certified manual shutoff valve with 1 8 NPT tap is an acceptable alternativetotestgaugeconnection PurchasetheoptionalA G A design...

Page 9: ...k all joints from manual shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see O...

Page 10: ...r button This will light pilot The pilot is attached to the front of burner The pilot can be seen through the glass panel If needed keep pressing ignitor button until pilot lights OPERATING HEATER Con...

Page 11: ...nerFlamePattern Ifburnerflamepatternisincorrect asshown in Figure 21 turn heater off see To Turn Off Gas to Appliance page 10 see Troubleshooting pages 12 through 14 Yellow Tipping CLEANING AND MAINTE...

Page 12: ...he following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignito...

Page 13: ...page 11 2 Contact local propane LP gas company 3 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate bu...

Page 14: ...ers If noise is excessive contact qualified ser vice person 1 Ventilate room Stop using odor causing products while heater is running 2 Refill supply tank 3 Locate and correct all leaks see Check ing...

Page 15: ...ss listed on the back page of this manual Send a check for 5 00 payable to DESA International Purchase this heater accessory from your local dealer If they cannot supply this ac cessory call DESA Inte...

Page 16: ...2 VENT FREE PROPANE LP GAS HEATER BLUE FLAME 6000 BTU HR 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 21 23 24 27 22 26 25 19 20 28 29 HEATER EXPLODED VIEW 12 2 12 1 ODS PILOT VP600B ILLUSTRATED PA...

Page 17: ...le 1 11 098249 01 Nut M5 2 12 099059 03 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 099386 02 Burner 1 14 099387 05 Pilot Tubing 1 15 098251 08 Injector 1...

Page 18: ..._______________________________________ _______________________________________________________________________________________________ ________________________________________________________________...

Page 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 20: ...swarranty Theheater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in origina...