2.

Mark two mounting screw locations on
wall (see Figure 5).

INSTALLING HEATER TO
WALL

Marking Screw Locations

1.

Determine where you will locate heater.

 WARNING: Maintain minimum

clearances shown in Figure 5. If
you can, provide greater clear-
ances from floor and joining wall.

FLOOR

JOINING WALL

20 1/4"

Minimum To

Maintain 3"

Clearance

From Floor

8 7/8"

Minimum To

Maintain 6"

Clearance
From Wall

7 3/4"

Mounting

Screw

Locations

Figure 5 - Mounting Screw Locations

INSTALLING TO
WALL

NOTICE: A qualified service per-
son must install heater. Follow
all local codes.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply
is not propane/LP, do not install heater. Call
dealer where you bought heater for proper
type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have
the items listed below.

external regulator (supplied by in-
staller, see page 8)

piping (check local codes)

sealant (resistant to propane/LP gas)

manual shutoff valve *

ground joint union

test gauge connection * (see Fig-
ure 13, page 8)

sediment trap

tee joint

pipe wrench

*  An A.G.A. design-certified manual shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. The
optional A.G.A. design-certified manual
shutoff valve can be purchased from your
dealer. See Accessory, page 15.

LOCATING HEATER

This heater is designed to be mounted on a
wall.

 

 WARNING: Maintain the mini-

mum clearances shown in Figure
4. If you can, provide greater clear-
ances from floor, ceiling, and
joining wall.

For convenience and efficiency, install heater

• where there is easy access for opera-
tion, inspection, and service

• in coldest part of room

Figure  4 - Mounting Clearances As Viewed
From Front of Heater

36"

3"

FLOOR

CEILING

Minimum

Minimum To Top Surfa
Of Carpeting, Tile Or O
Combustible Material

6"

Minimum
From
Sides Of
Heater

Right
Side

Left
Side

 WARNING: Never install the

heater

• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the heater

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

 CAUTION: If you install the

heater in a home garage

• heater pilot and burner must

be at least 18 inches above
floor

• locate heater where moving

vehicle will not hit it

 CAUTION: This heater cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities in the air (such
as tobacco smoke) exist, may
discolor walls.

IMPORTANT:

 Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation, 
pages 3 through 5.

Minimum To
Top Surface
Of Carpeting,
Tile Or Other
Combustible
Material

Summary of Contents for 6000 BTU/HR

Page 1: ...r call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from t...

Page 2: ...hbor s phone Follow the gas supplier s instructions if you cannot reach your gas supplier call the fire department 4 Never install the heater in a recreational vehicle where curtains furniture clothin...

Page 3: ...ew materials increased insulation and new construction methods help reduce heat loss in homes Home own ers weather strip and caulk around windows and doors to keep the cold air out and the warm air in...

Page 4: ...plates and floors between wall ceil ing joints between wall panels at penetrations for plumbing electrical and gas lines and at other openings If your home meets all of the three criteria above you m...

Page 5: ...ze of ventilation grills or ducts WARNING Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Fig...

Page 6: ...TING HEATER This heater is designed to be mounted on a wall WARNING Maintainthemini mumclearancesshowninFigure 4 Ifyoucan providegreaterclear ances from floor ceiling and joining wall Forconveniencean...

Page 7: ...ace Thin or Thick Wall thick wall shown Solid Wall Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large openings of slots over screwheads Sli...

Page 8: ...o gas pip ing and or fittings Figure 13 Gas Connection An A G A design certified manual shutoff valve with 1 8 NPT tap is an acceptable alternativetotestgaugeconnection PurchasetheoptionalA G A design...

Page 9: ...k all joints from manual shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see O...

Page 10: ...r button This will light pilot The pilot is attached to the front of burner The pilot can be seen through the glass panel If needed keep pressing ignitor button until pilot lights OPERATING HEATER Con...

Page 11: ...nerFlamePattern Ifburnerflamepatternisincorrect asshown in Figure 21 turn heater off see To Turn Off Gas to Appliance page 10 see Troubleshooting pages 12 through 14 Yellow Tipping CLEANING AND MAINTE...

Page 12: ...he following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignito...

Page 13: ...page 11 2 Contact local propane LP gas company 3 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate bu...

Page 14: ...ers If noise is excessive contact qualified ser vice person 1 Ventilate room Stop using odor causing products while heater is running 2 Refill supply tank 3 Locate and correct all leaks see Check ing...

Page 15: ...ss listed on the back page of this manual Send a check for 5 00 payable to DESA International Purchase this heater accessory from your local dealer If they cannot supply this ac cessory call DESA Inte...

Page 16: ...2 VENT FREE PROPANE LP GAS HEATER BLUE FLAME 6000 BTU HR 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 21 23 24 27 22 26 25 19 20 28 29 HEATER EXPLODED VIEW 12 2 12 1 ODS PILOT VP600B ILLUSTRATED PA...

Page 17: ...le 1 11 098249 01 Nut M5 2 12 099059 03 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 099386 02 Burner 1 14 099387 05 Pilot Tubing 1 15 098251 08 Injector 1...

Page 18: ..._______________________________________ _______________________________________________________________________________________________ ________________________________________________________________...

Page 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 20: ...swarranty Theheater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in origina...

Reviews: